The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Effect of Intraoperative High Inspired Oxygen Fraction on Surgical Site Infection, Postoperative Nausea and Vomiting, and Pulmonary Function: Systematic Review and Meta-analysis of Randomized Controlled Trials
Open accessAbstract
Background: Intraoperative high inspired oxygen fraction (F io 2 ) is thought to reduce the incidence of surgical site infection (SSI) and postoperative nausea and vomiting, and to promote postoperative atelectasis. Methods: The authors searched for randomized trials (till September 2012) comparing intraoperative high with normal F io 2 in adults undergoing surgery with general anesthesia and reporting on SSI, nausea or vomiting, or pulmonary outcomes. Results: The authors included 22 trials (7,001 patients) published in 26 reports. High F io 2 ranged from 80 to 100% (median, 80%); normal F io 2 ranged from 30 to 40% (median, 30%). In nine trials (5,103 patients, most received prophylactic antibiotics), the incidence of SSI decreased from 14.1% with normal F io 2 to 11.4% with high F io 2 ; risk ratio, 0.77 (95% CI, 0.59–1.00). After colorectal surgery, the incidence of SSI decreased from 19.3 to 15.2%; risk ratio, 0.78 (95% CI, 0.60–1.02). In 11 trials (2,293 patients), the incidence of nausea decreased from 24.8% with normal F io 2 to 19.5% with high F io 2 ; risk ratio, 0.79 (95% CI, 0.66–0.93). In patients receiving inhalational anesthetics without prophylactic antiemetics, high F io 2 provided a significant protective effect against both nausea and vomiting. Nine trials (3,698 patients) reported on pulmonary outcomes. The risk of atelectasis was not increased with high F io 2 . Conclusions: Intraoperative high F io 2 further decreases the risk of SSI in surgical patients receiving prophylactic antibiotics, has a weak beneficial effect on nausea, and does not increase the risk of postoperative atelectasis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Schietroma, M., Carlei, F., Cecilia, E. M., Piccione, F., Bianchi, Z., & Amicucci, G. (2014) · Journal of Gastrointestinal Surgery · doi:10.1007/s11605-013-2378-z · Cited by 37
Retracted
Cited by
Gustafsson, U. O., Scott, M. J., Hubner, M., Nygren, J., Demartines, N., Francis, N., Rockall, T. A., Young‐Fadok, T. M., Hill, A. G., Soop, M., et al. (2019) · World Journal of Surgery · doi:10.1007/s00268-018-4844-y · Cited by 2,119
Postoperative pulmonary complications
Miskovic, A., & Lumb, A. B. (2017) · British Journal of Anaesthesia · doi:10.1093/bja/aex002 · Cited by 1,123
Bench-to-bedside review: the effects of hyperoxia during critical illness
Helmerhorst, H. J. F., Schultz, M. J., van der Voort, P. H. J., de Jonge, E., & van Westerloo, D. J. (2015) · Critical Care · doi:10.1186/s13054-015-0996-4 · Cited by 187
Effect of intraoperative hyperoxia on the incidence of surgical site infections: a meta-analysis
Cohen, B., Schacham, Y. N., Ruetzler, K., Ahuja, S., Yang, D., Mascha, E. J., Barclay, A. B., Hung, M. H., & Sessler, D. I. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.02.027 · Cited by 59
Metadata
- Authors
- Hovaguimian, F., Lysakowski, C., Elia, N., & Tramèr, M. R.
- Venue
- Anesthesiology
- Published
- 2013-08
- Volume
- 119
- Issue
- 2
- Pages
- 303-316
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2035118431
- Cited by
- 176
- References
- 1
- FWCI
- 17.66
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of Intraoperative High Inspired Oxygen Fraction on Surgical Site Infection, Postoperative Nausea and Vomiting, and Pulmonary Function: Systematic Review and Meta-analysis of Randomized Controlled Trials. https://app.cochat.ai/papers/10.1097/aln.0b013e31829aaff4
- The paper
- Hovaguimian, F., Lysakowski, C., Elia, N., & Tramèr, M. R. (2013). Effect of Intraoperative High Inspired Oxygen Fraction on Surgical Site Infection, Postoperative Nausea and Vomiting, and Pulmonary Function: Systematic Review and Meta-analysis of Randomized Controlled Trials. Anesthesiology. https://doi.org/10.1097/aln.0b013e31829aaff4
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.