CoChat

Loop Electrosurgical Excision Procedure and Risk of Preterm Birth: A Systematic Review and Meta-analysis

Open access
Conner, Shayna N., Frey, Heather A., Cahill, Alison G., Macones, George A., Colditz, Graham A., Tuuli, Methodius G. · 2014 · Obstetrics & Gynecology
Cited by 102

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To assess whether loop electrosurgical excision procedure (LEEP) increases the risk for preterm birth before 37 weeks of gestation and clarify whether the increased risk for preterm birth is attributable to the procedure itself or to risk factors associated with cervical dysplasia. DATA SOURCES: Two authors performed a search of the relevant data through February 2013 using PubMed, Embase, Scopus, CENTRAL, and ClinicalTrials.gov. METHODS OF STUDY SELECTION: We included observational studies that compared rates of preterm birth in women with prior LEEP with women with no history of cervical excision. Nineteen of 559 identified studies met selection criteria. TABULATION, INTEGRATION, AND RESULTS: We compared women with a history of LEEP with two unexposed groups without a history of cervical excision: 1) women with an unknown or no history of cervical dysplasia; and 2) women with a history of cervical dysplasia but no cervical excision. The primary outcome was preterm birth before 37 weeks of gestation. Secondary outcomes were preterm birth before 34 weeks of gestation, spontaneous preterm birth, preterm premature rupture of membranes, and perinatal mortality. DerSimonian-Laird random effects models were used. We assessed heterogeneity between studies using the Q and I tests. Stratified analyses and metaregression were performed to assess confounding. Nineteen studies were included with a total of 6,589 patients with a history of LEEP and 1,415,015 without. Overall, LEEP was associated with an increased risk of preterm birth before 37 weeks of gestation (pooled relative risk 1.61, 95% confidence interval [CI] 1.35-1.92). However, no increased risk was found when women with a history of LEEP were compared with women with a history cervical dysplasia but no cervical excision (pooled relative risk 1.08, 95% CI 0.88-1.33). CONCLUSION: Women with a history of LEEP have similar risk of preterm birth when compared with women with prior dysplasia but no cervical excision. Common risk factors for both preterm birth and dysplasia likely explain findings of association between LEEP and preterm birth, but LEEP itself may not be an independent risk factor for preterm birth.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/aog.0000000000000174

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 102

Metadata

Authors
Conner, S. N., Frey, H. A., Cahill, A. G., Macones, G. A., Colditz, G. A., & Tuuli, M. G.
Venue
Obstetrics & Gynecology
Published
2014-04
Volume
123
Issue
4
Pages
752-761
ISSN
0029-7844 (ISSN-L)
OpenAlex
W2055889778
Cited by
102
References
3
FWCI
10.56
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Loop Electrosurgical Excision Procedure and Risk of Preterm Birth: A Systematic Review and Meta-analysis. https://app.cochat.ai/papers/10.1097/aog.0000000000000174
The paper
Conner, S. N., Frey, H. A., Cahill, A. G., Macones, G. A., Colditz, G. A., & Tuuli, M. G. (2014). Loop Electrosurgical Excision Procedure and Risk of Preterm Birth: A Systematic Review and Meta-analysis. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0000000000000174

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.