The 2008 National Institute of Child Health and Human Development Workshop Report on Electronic Fetal Monitoring: Update on Definitions, Interpretation, and Research Guidelines
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
In April 2008, the Eunice Kennedy Shriver National Institute of Child Health and Human Development, the American College of Obstetricians and Gynecologists, and the Society for Maternal-Fetal Medicine partnered to sponsor a 2-day workshop to revisit nomenclature, interpretation, and research recommendations for intrapartum electronic fetal heart rate monitoring. Participants included obstetric experts and representatives from relevant stakeholder groups and organizations. This article provides a summary of the discussions at the workshop. This includes a discussion of terminology and nomenclature for the description of fetal heart tracings and uterine contractions for use in clinical practice and research. A three-tier system for fetal heart rate tracing interpretation is also described. Lastly, prioritized topics for future research are provided.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electronic fetal heart rate monitoring: Research guidelines for interpretation
(1997) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(97)70079-6 · Cited by 419
RETIRED: Fetal Health Surveillance: Antepartum and Intrapartum Consensus Guideline
Liston, R., Sawchuck, D., Young, D., Brassard, N., Campbell, K., Davies, G., Ehman, W., Farine, D., Farquharson, D., Hamilton, E., et al. (2007) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(16)32615-9 · Cited by 278
A framework for standardized management of intrapartum fetal heart rate patterns
Parer, J. T., & Ikeda, T. (2007) · American Journal of Obstetrics and Gynecology · doi:10.1016/j.ajog.2007.03.037 · Cited by 153
Cited by
Spong, C. Y., Berghella, V., Wenstrom, K. D., Mercer, B. M., & Saade, G. R. (2012) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3182704880 · Cited by 712
Self-citationMelamed, N., Baschat, A., Yinon, Y., Athanasiadis, A., Mecacci, F., Figueras, F., Berghella, V., Nazareth, A., Tahlak, M., McIntyre, H. D., et al. (2021) · International Journal of Gynecology & Obstetrics · doi:10.1002/ijgo.13522 · Cited by 570
Leduc, D., Biringer, A., Lee, L., Dy, J., Corbett, T., Leduc, D., Biringer, A., Duperron, L., Dy, J., Lange, I., et al. (2013) · Journal of Obstetrics and Gynaecology Canada · doi:10.1016/s1701-2163(15)30842-2 · Cited by 347
Chau, A., Bibbo, C., Huang, C.-C., Elterman, K. G., Cappiello, E. C., Robinson, J. N., & Tsen, L. C. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000001798 · Cited by 272
Antepartum Fetal Surveillance: ACOG Practice Bulletin, Number 229
(2021) · Obstetrics & Gynecology · doi:10.1097/aog.0000000000004410 · Cited by 106
Metadata
- Authors
- Macones, G. A., Hankins, G. D. V., Spong, C. Y., Hauth, J., & Moore, T.
- Venue
- Obstetrics & Gynecology
- Published
- 2008-09
- Volume
- 112
- Issue
- 3
- Pages
- 661-666
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2094798800
- Cited by
- 696
- References
- 3
- FWCI
- 32.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.