The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Robotic-Assisted Hysterectomy for Endometrial Cancer Compared With Traditional Laparoscopic and Laparotomy Approaches: A Systematic Review
Abstract
OBJECTIVE: To summarize comparative studies describing clinical outcomes of robotic-assisted surgeries compared with traditional laparoscopic or laparotomy techniques for the treatment of endometrial cancer. DATA SOURCES: Using search words "robotic hysterectomy" and "endometrial cancer," 22 citations were identified from Medline and PubMed (2005 to February 2010). METHODS OF STUDY SELECTION: We selected English language studies reporting at least 25 robotic cases compared with laparoscopic or laparotomy cases that also addressed surgical technique, complications, and perioperative outcomes. Patients underwent total hysterectomy, bilateral salpingo-oophorectomy, and lymphadenectomy. TABULATION, INTEGRATION, AND RESULTS: Eight eligible comparative studies were identified that included 1,591 patients (robotic=589, laparoscopic=396, and laparotomy=606). Pooled means of the resected aortic lymph nodes for robotic hysterectomy and laparoscopy were 10.3 and 7.8 (P=.15), and robotic hysterectomy and laparotomy were 9.4 and 5.7 (P=.28). Pooled means of pelvic lymph nodes for robotic and laparoscopic hysterectomy were 18.5 and 17.8 (P=.95) and 18.0 compared with 14.5 (P=.11) for robotic hysterectomy compared with laparotomy. Estimated blood loss was reduced in robotic hysterectomy compared with laparotomy (P<.005) and laparoscopy (P=.001). Length of stay was shorter for both robotic and laparoscopic cases compared with laparotomy (P<.01). Operative time for robotic hysterectomy was similar to laparoscopic cases but was greater than laparotomy (P<.005). Conversion to laparotomy for laparoscopic hysterectomy was 9.9% compared with 4.9% for robotic cases (P=.06). Vascular, bowel, and bladder injuries; cuff dehiscence; and thromboembolic complications were similar for each surgical method. Transfusions for robotic hysterectomy compared with laparotomy was 1.7% and 7.2% (P=.06) and robotic hysterectomy compared were laparoscopy was 2.6% and 5.0% (P=.22). CONCLUSION: Perioperative clinical outcomes for robotic and laparoscopic hysterectomy appear similar with the exception of less blood loss for robotic cases and longer operative times for robotic and laparoscopy cases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The combination of estimates from different experiments
Cochran, W. G. (1954) · Biometrics · doi:10.2307/3001666 · Cited by 5,380
A comparison of methods to detect publication bias in meta‐analysis
Macaskill, P., Walter, S. D., & Irwig, L. (2001) · Statistics in Medicine · doi:10.1002/sim.698 · Cited by 1,286 · cited 1×
“3) NR NR 3 (10) NR LPT 40 0 NR NR 6 (15) N/A DeNardis et al, 200820 RH 56 NR NR NR 0 3 (5.”
Cited by
Makker, V., MacKay, H., Ray-Coquard, I., Levine, D. A., Westin, S. N., Aoki, D., & Oaknin, A. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00324-8 · Cited by 674
Current recommendations and recent progress in endometrial cancer
Brooks, R. A., Fleming, G. F., Lastra, R. R., Lee, N. K., Moroney, J. W., Son, C. H., Tatebe, K., & Veneris, J. L. (2019) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21561 · Cited by 573
Sorosky, J. I. (2012) · Obstetrics & Gynecology · doi:10.1097/aog.0b013e3182605bf1 · Cited by 332
Yu, H.-Y., Hevelone, N. D., Lipsitz, S. R., Kowalczyk, K. J., & Hu, J. C. (2012) · Journal of Urology · doi:10.1016/j.juro.2011.11.089 · Cited by 291
Acholonu, U. C., Chang-Jackson, S.-C. R., Radjabi, A. R., & Nezhat, F. R. (2012) · Journal of Minimally Invasive Gynecology · doi:10.1016/j.jmig.2012.02.006 · Cited by 29
Metadata
- Authors
- Gaia, G., Holloway, R. W., Santoro, L., Ahmad, S., Di Silverio, E., & Spinillo, A.
- Venue
- Obstetrics & Gynecology
- Published
- 2010-12
- Volume
- 116
- Issue
- 6
- Pages
- 1422-1431
- ISSN
- 0029-7844 (ISSN-L)
- OpenAlex
- W2056257577
- Cited by
- 165
- References
- 2
- FWCI
- 18.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robotic-Assisted Hysterectomy for Endometrial Cancer Compared With Traditional Laparoscopic and Laparotomy Approaches: A Systematic Review. https://app.cochat.ai/papers/10.1097/aog.0b013e3181f74153
- The paper
- Gaia, G., Holloway, R. W., Santoro, L., Ahmad, S., Di Silverio, E., & Spinillo, A. (2010). Robotic-Assisted Hysterectomy for Endometrial Cancer Compared With Traditional Laparoscopic and Laparotomy Approaches: A Systematic Review. Obstetrics & Gynecology. https://doi.org/10.1097/aog.0b013e3181f74153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.