Cited by 17Glaucoma and retinal disordersOptical Coherence Tomography ApplicationsCorneal surgery and disorders

The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.

Optical coherence tomography imaging for glaucoma - today and tomorrow

Leung, Christopher Kai-Shun·2016·Asia-Pacific Journal of Ophthalmology

Abstract

Digital imaging technologies for glaucoma diagnostics have evolved rapidly over the recent years. From time-domain optical coherence tomography (OCT) to spectral-domain and swept-source OCTs, the application of OCT for analysis of the anterior chamber angle and the optic nerve head (ONH) is expanding. The second-generation anterior segment swept-source OCT is able to image the configuration of the anterior chamber angle in 3 dimensions in less than 1 second and perform 360-degree analysis of the anterior chamber angle width for detection of angle closure. The morphology, density, and dimensions of the crystalline lens in relation to the anterior chamber can now be examined from the anterior corneal surface to the posterior lens surface, facilitating the investigation of the involvement of the crystalline lens in primary angle closure. Spectral-domain and swept-source OCTs have improved the measurement reliability of the lamina cribrosa and the neuroretinal rim configurations. Studying the deformation of the lamina cribrosa and ONH surfaces is relevant to decipher the mechanisms of ONH damage in the development and progression of glaucoma. Software and algorithms for automatic analysis of the anterior chamber angle dimensions and deformation of the ONH and lamina cribrosa surfaces are required to process large volumetric data sets, and they are under active development. It is expected that new imaging technologies will improve the detection and risk assessment of angle-closure and open-angle glaucomas.

Overview

Integrity signals

Registry

Crossref · 10.1097/apo.0000000000000179

Cites

41 of 41 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Show all 41 references

Cited by

Sorted by citations

See all 17

Metadata

Authors
Leung, C. K.-S.
Affiliations
Chinese University of Hong Kong (HK)
Corresponding author
Leung, Christopher Kai-Shun
Venue
Asia-Pacific Journal of Ophthalmology
Published
2016
Volume
5
Issue
1
Pages
11-16
ISSN
2162-0989 (ISSN-L)
OpenAlex
W2320334438
Cited by
17
References
41
Citations by year
2025: 2 · 2024: 3 · 2022: 1 · 2021: 2 · 2020: 3 · 2019: 2 · 2018: 1 · 2017: 2
FWCI
0.32
Type
journal article
Language
en
Open access
closed
Locations
  • Asia-Pacific Journal of Ophthalmology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
  • Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
Keywords
optical coherence tomography, glaucoma, anterior chamber angle, angle-closure glaucoma, open-angle glaucoma, optic nerve head, lamina cribrosa, neuroretinal rim, crystalline lens, swept-source optical coherence tomography, spectral-domain optical coherence tomography, time-domain OCT, anterior segment imaging
MeSH terms
Anterior Chamber, Glaucoma, Humans, Nerve Fibers, Optic Disk, Optic Nerve Diseases, Reproducibility of Results, Tomography, Optical Coherence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review