Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 210

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Gamma Nails Revisited: Gamma Nails Versus Compression Hip Screws in the Management of Intertrochanteric Fractures of the Hip: A Meta-Analysis

Bhandari, Mohit, Schemitsch, Emil, Jönsson, Anders, Zlowodzki, Michael, Haidukewych, George J · 2009 · Journal of Orthopaedic Trauma

Abstract

BACKGROUND: Concerns about the Gamma nail have largely been fueled by early randomized trials and meta-analyses suggesting an increased risk of subsequent femoral shaft fractures when compared with compression hip screws. Whereas meta-analyses favor compression hip screws over first-generation Gamma nails, little is known as to whether the newer Gamma nail designs and the improved learning curve associated with the implants have reduced the risk of femoral shaft fracture. The current meta-analysis aimed to explore the effects of time and Gamma Nail design on the risks of femoral shaft fracture after treatment of extracapsular hip fractures. METHODS: We searched computerized databases (Medline, Cochrane, and SciSearch) for published randomized clinical trials from 1969 to 2002, and we identified additional studies through hand searches of major orthopedic journals, bibliographies of major orthopedic texts, and personal files. Two investigators independently graded study quality and abstracted relevant data. We abstracted information on subsequent femoral shaft fracture rates from studies. We pooled data using a random-effects model and tested for heterogeneity using the I test. We conducted sensitivity analyses by date and by generation of the Gamma nail. We further conducted a cumulative meta-analysis to explore the treatment effect over time. RESULTS: We identified 25 relevant randomized trials from 1991 to 2005. In earlier studies (N = 1585 patients), Gamma nails increased the risk of femoral shaft fracture 4.5 times compared with a compression hip screw (95% confidence interval: 1.78-11.36, P = 0.0014, I(2) = 0%). However, among the most recent studies (2000-2005), Gamma nails did not significantly increase femoral shaft fracture risk (relative risk = 1.65, 95% confidence interval: 0.50-5.44, P = 0.41, I(2) = 0%). The most recent study (2005) found no difference in femoral fracture rates (relative risk = 1.03, 95% confidence interval = 0.06-16.2, P = 0.99). CONCLUSIONS: Our meta-analysis of randomized trials suggests that previous concerns about increased femoral shaft fracture risk with Gamma nails have been resolved with improved implant design and improved learning curves with the device. Earlier meta-analyses and randomized trials should be interpreted with caution in light of more recent evidence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/bot.0b013e318162f67f

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 210

Metadata

Authors
Bhandari, M., Schemitsch, E., Jönsson, A., Zlowodzki, M., & Haidukewych, G. J.
Venue
Journal of Orthopaedic Trauma
Published
2009-07
Volume
23
Issue
6
Pages
460-464
ISSN
0890-5339 (ISSN-L)
OpenAlex
W2017222869
Cited by
210
References
2
FWCI
1.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.