STUDY DESIGN: Analysis of the prospective AOSpine CSM-International and North America datasets and survey of AO Spine International. OBJECTIVE: This study aims to define the minimum clinically important difference (MCID) of the modified Japanese Orthopaedic Association (mJOA) in patients with degenerative cervical myelopathy (DCM). SUMMARY OF BACKGROUND DATA: The mJOA is the most frequently used clinician-administered tool to assess functional status in patients with DCM. By defining its MCID, clinicians can better evaluate treatment outcomes for this condition. METHODS: Three methods were used to determine the MCID of the mJOA: (1) distribution-based, (2) anchor-based and receiver operating characteristic (ROC) analysis, and (3) professional opinion. Distribution-based methods were used to estimate the MCID by computing the half standard deviation and standard error of measurement. Using anchor-based methods, mJOA at 12 months after surgery was compared between patients who were "slightly improved" on the Neck Disability Index (NDI) and those who were "unchanged." ROC analysis was performed to compute a discrete integer value for the MCID that yielded the smallest difference between sensitivity and specificity. We repeated anchor-based methods for patients with mild (mJOA: 15-17), moderate (mJOA: 12-14), and severe disease (mJOA <12). RESULTS: The half standard deviation of the baseline mJOA was 1.36 and the standard error of measurement was 1.21. The difference in mJOA between patients who "slightly improved" on the NDI and "unchanged" patients was 1.11. ROC analysis yielded a value of 2 for the MCID. The survey of 416 spine professionals confirmed these estimates: the mean response was 1.65 ± 0.66. The MCID significantly varied depending on myelopathy severity: ROC analysis yielded a threshold of 1 for mild, 2 for moderate, and 3 for severe patients. CONCLUSION: The MCID of the mJOA is estimated to be between 1 and 2 points and varies with myelopathy severity. This knowledge will enable clinicians to identify meaningful functional improvements in DCM patients. LEVEL OF EVIDENCE: N/A.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0000000000001127

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Tetreault, L., Nouri, A., Kopjar, B., Côté, P., & Fehlings, M. G.
Venue
Spine
Published
2015-11
Volume
40
Issue
21
Pages
1653-1659
ISSN
0362-2436 (ISSN-L)
OpenAlex
W1868431376
Cited by
193
References
2
FWCI
9.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Minimum Clinically Important Difference of the Modified Japanese Orthopaedic Association Scale in Patients with Degenerative Cervical Myelopathy. https://app.cochat.ai/papers/10.1097/brs.0000000000001127
The paper
Tetreault, L., Nouri, A., Kopjar, B., Côté, P., & Fehlings, M. G. (2015). The Minimum Clinically Important Difference of the Modified Japanese Orthopaedic Association Scale in Patients with Degenerative Cervical Myelopathy. Spine. https://doi.org/10.1097/brs.0000000000001127

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.