CoChat

Efficacy of Diffusion Tensor Imaging Indices in Assessing Postoperative Neural Recovery in Cervical Spondylotic Myelopathy

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Abstract

Study design Prospective observational cohort study. Objective The aim of this study was to analyze the efficacy of diffusion tensor imaging (DTI) anisotropy indices in predicting the postoperative recovery in cervical spondylotic myelopathy (CSM) patients and to describe postoperative changes in the DTI indices based on neurological recovery after surgery. Summary of background data Surgical results of CSM are unpredictable and cannot be estimated based on preoperative MRI. DTI indices were found to have good sensitivity to detect changes in CSM, but their efficacy in predicting postoperative recovery and postoperative changes in DTI indices has not been studied before. Methods Thirty-five patients who underwent surgical decompression for cervical spondylotic myelopathy underwent DTI evaluation preoperatively and postoperatively at 12 months. DTI indices-fractional anisotropy, apparent diffusion coefficient (ADC), relative anisotropy, volume ratio, and eigen vectors (E1, E2, and E3)-were obtained and clinical evaluations were made preoperatively and 12 months postoperatively. Results Twenty-six patients were available for final follow-up at 12 months. Twenty patients showed improvement by at least 1 Nurick grade, five maintained the preoperative Nurick grade status and one patient was noted to have deterioration by 1 grade. The preoperative DTI values could not predict neurological recovery patterns postoperatively. Although conventional MRI showed adequate decompression in…

Overview

Integrity signals

Registry

Crossref · 10.1097/brs.0000000000001667

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Research works printed but not linked: 1

  1. Rajasekaran, 2014, The assessment of neuronal status in normal and cervical spondylotic myelopathy using diffusion tensor imaging Spine, 39, 1183

Cited by

Metadata

Authors
Rajasekaran, S., Kanna, R. M., Chittode, V. S., Maheswaran, A., Aiyer, S. N., & Shetty, A. P.
Affiliations
Ganga Hospital (IN)
Corresponding author
Rajasekaran, S.
Venue
Spine
Published
2017-01-01
Volume
42
Issue
1
Pages
8-13
ISSN
  • 0362-2436 (ISSN-L)
  • 1528-1159
OpenAlex
W2422159756
Cited by
29
References
30
Citations by year
2025: 2 · 2024: 3 · 2023: 3 · 2022: 4 · 2020: 4 · 2019: 6 · 2018: 1 · 2017: 5
FWCI
4.81
Type
journal article
Language
en
Open access
closed
Locations
  • Spine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Cervical and Thoracic Myelopathy
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced Neuroimaging Techniques and Applications
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Spine and Intervertebral Disc Pathology
Keywords
cervical spondylotic myelopathy, diffusion tensor imaging, fractional anisotropy, apparent diffusion coefficient, postoperative neurological recovery, surgical decompression, surgical outcome prediction, Nurick grade, white matter fiber orientation
MeSH terms
Adult, Aged, Aged, 80 and over, Female, Humans, Magnetic Resonance Imaging, Male, Middle Aged, Spinal Cord Compression, Treatment Outcome, Decompression, Surgical, Recovery of Function, Spondylosis, Diffusion Tensor Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.