In Brief Study Design. A reliability assessment of standardized magnetic resonance imaging (MRI) interpretations and measurements. Objective. To determine the intra- and inter-reader reliability of MRI features of lumbar spinal stenosis (SPS), including severity of central, subarticular, and foraminal stenoses, grading of nerve root impingement, and measurements of cross-sectional area of the spinal canal and thecal sac. Summary of Background Data. MRI is commonly used to assess patients with spinal stenosis. Although a number of studies have evaluated the reliability of certain MRI characteristics, comprehensive evaluation of the reliability of MRI readings in spinal stenosis is lacking. Methods. Fifty-eight randomly selected MR images from patients with SPS enrolled in the Spine Patient Outcomes Research Trial were evaluated. Qualitative ratings of imaging features were performed according to defined criteria by 4 independent readers (3 radiologists and 1 orthopedic surgeon). A sample of 20 MRIs was reevaluated by each reader at least 1 month later. Weighted κ statistics were used to characterize intra- and inter-reader reliability for qualitative rating data. Separate quantitative measurements were performed by 2 other radiologists. Intraclass correlation coefficients and summaries of measurement error were used to characterize reliability for quantitative measurements. Results. Intra-reader reliability was higher than inter-reader reliability for all features. Inter-reader reliability in assessing central stenosis was substantial, with an overall κ of 0.73 (95% CI 0.69–0.77). Foraminal stenosis and nerve root impingement showed moderate to substantial agreement with overall κ of 0.58 (95% CI 0.53–0.63) and 0.51 (95% CI 0.42–0.59), respectively. Subarticular zone stenosis yielded the poorest agreement (overall κ 0.49; 95% CI 0.42–0.55) and showed marked variability in agreement between reader pairs. Quantitative measures showed inter-reader intraclass correlation coefficients ranging from 0.58 to 0.90. The mean absolute difference between readers in measured thecal sac area was 128 mm2 (13%). Conclusion. The imaging characteristics of spinal stenosis assessed in this study showed moderate to substantial reliability; future studies should assess whether these findings have prognostic significance in SPS patients. Magnetic resonance imaging (MRI) characteristics were studied in patients with lumbar spinal stenosis with or without degenerative spondylolisthesis, who were eligible surgical candidates enrolled in the Spine Patient Outcomes Research Trial (SPORT). Characteristics evaluated included severity of central, subarticular, and foraminal stenoses, grading of nerve root impingement, and quantitative measurements of cross-sectional area of the spinal canal and thecal sac. A number of features had substantial reliability and should be further evaluated as potential prognostic indicators in patients with spinal stenosis (SPS).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0b013e3181791af3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 191

Metadata

Authors
Lurie, J. D., Tosteson, A. N., Tosteson, T. D., Carragee, E., Carrino, J., Kaiser, J., Sequeiros, R. T. B., Lecomte, A. R., Grove, M. R., Blood, E. A., Pearson, L. H., Weinstein, J. N., & Herzog, R.
Venue
Spine
Published
2008-06
Volume
33
Issue
14
Pages
1605-1610
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2072639042
Cited by
191
References
1
FWCI
6.32
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of Readings of Magnetic Resonance Imaging Features of Lumbar Spinal Stenosis. https://app.cochat.ai/papers/10.1097/brs.0b013e3181791af3
The paper
Lurie, J. D., Tosteson, A. N., Tosteson, T. D., Carragee, E., Carrino, J., Kaiser, J., Sequeiros, R. T. B., Lecomte, A. R., Grove, M. R., Blood, E. A., Pearson, L. H., Weinstein, J. N., & Herzog, R. (2008). Reliability of Readings of Magnetic Resonance Imaging Features of Lumbar Spinal Stenosis. Spine. https://doi.org/10.1097/brs.0b013e3181791af3

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.