Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 518

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Comparison of BRYAN Cervical Disc Arthroplasty With Anterior Cervical Decompression and Fusion: Clinical and Radiographic Results of a Randomized, Controlled, Clinical Trial

Heller, John G., Sasso, Rick C., Papadopoulos, Stephen M., Anderson, Paul A., Fessler, Richard G., Hacker, Robert J., Coric, Domagoj, Cauthen, Joseph C., Riew, Daniel K.·2009·Spine

Abstract

STUDY DESIGN: A prospective, randomized, multicenter study of surgical treatment of cervical disc disease. OBJECTIVE: To assess the safety and efficacy of cervical disc arthroplasty using a new arthroplasty device at 24-months follow-up. SUMMARY OF BACKGROUND DATA: Cervical disc arthroplasty preserves motion in the cervical spine. It is an alternative to fusion after neurologic decompression, whereas anterior decompression and fusion provides a rigorous comparative benchmark of success. METHODS: We conducted a randomized controlled multicenter clinical trial enrolling patients with cervical disc disease. Ultimately 242 received the investigational device (Bryan Cervical Disc), and 221 patients underwent a single-level anterior cervical discectomy and decompression and fusion as a control group. Patients completed clinical and radiographic follow-up examinations at regular intervals for 2 years after surgery. RESULTS: Analysis of 12- and 24-month postoperative data showed improvement in all clinical outcome measures for both groups; however, 24 months after surgery, the investigational group patients treated with the artificial disc had a statistically greater improvement in the primary outcome variables: Neck disability index score (P = 0.025) and overall success (P = 0.010). With regard to implant- or implant/surgical-procedure-associated serious adverse events, the investigational group had a rate of 1.7% and the control group, 3.2%. There was no statistical difference between the 2 groups with regard to the rate of secondary surgical procedures performed subsequent to the index procedure. Patients who received the artificial cervical disc returned to work nearly 2 weeks earlier than the fusion patients (P = 0.015). CONCLUSION: Two-year follow-up results indicate that cervical disc arthroplasty is a viable alternative to anterior cervical discectomy and fusion in patients with persistently symptomatic, single-level cervical disc disease.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/brs.0b013e31818ee263

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 518

Metadata

Authors
Heller, J. G., Sasso, R. C., Papadopoulos, S. M., Anderson, P. A., Fessler, R. G., Hacker, R. J., Coric, D., Cauthen, J. C., & Riew, D. K.
Venue
Spine
Published
2009-01
Volume
34
Issue
2
Pages
101-107
ISSN
0362-2436 (ISSN-L)
OpenAlex
W2077481395
Cited by
518
References
1
FWCI
36.90
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of BRYAN Cervical Disc Arthroplasty With Anterior Cervical Decompression and Fusion: Clinical and Radiographic Results of a Randomized, Controlled, Clinical Trial. https://app.cochat.ai/papers/10.1097/brs.0b013e31818ee263
The paper
Heller, J. G., Sasso, R. C., Papadopoulos, S. M., Anderson, P. A., Fessler, R. G., Hacker, R. J., Coric, D., Cauthen, J. C., & Riew, D. K. (2009). Comparison of BRYAN Cervical Disc Arthroplasty With Anterior Cervical Decompression and Fusion: Clinical and Radiographic Results of a Randomized, Controlled, Clinical Trial. Spine. https://doi.org/10.1097/brs.0b013e31818ee263

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.