The Evidence for Intraoperative Neurophysiological Monitoring in Spine Surgery: Does It Make a Difference?
Abstract
OBJECTIVE: The objective of this article was to undertake a systematic review of the literature to determine whether IOM is able to sensitively and specifically detect intraoperative neurologic injury during spine surgery and to assess whether IOM results in improved outcomes for patients during these procedures. SUMMARY AND BACKGROUND DATA: Although relatively uncommon, perioperative neurologic injury, in particular spinal cord injury, is one of the most feared complications of spinal surgery. Intraoperative neuromonitoring (IOM) has been proposed as a method which could reduce perioperative neurologic complications after spine surgery. METHODS: A systematic review of the English language literature was undertaken for articles published between 1990 and March 2009. MEDLINE, EMBASE, and Cochrane Collaborative Library databases were searched, as were the reference lists of published articles examining the use of IOM in spine surgery. Two independent reviewers assessed the level of evidence quality using the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) criteria, and disagreements were resolved by consensus. RESULTS: A total of 103 articles were initially screened and 32 ultimately met the predetermined inclusion criteria. We determined that there is a high level of evidence that multimodal IOM is sensitive and specific for detecting intraoperative neurologic injury during spine surgery. There is a low level of evidence that IOM reduces the rate of new or worsened perioperative neurologic deficits. There is very low evidence that an intraoperative response to a neuromonitoring alert reduces the rate of perioperative neurologic deterioration. CONCLUSION: Based on strong evidence that multimodality intraoperative neuromonitoring (MIOM) is sensitive and specific for detecting intraoperative neurologic injury during spine surgery, it is recommended that the use of MIOM be considered in spine surgery where the spinal cord or nerve roots are deemed to be at risk, including procedures involving deformity correction and procedures that require the placement of instrumentation. There is a need to develop evidence-based protocols to deal with intraoperative changes in MIOM and to validate these prospectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Updated Method Guidelines for Systematic Reviews in the Cochrane Collaboration Back Review Group
van Tulder, M., Furlan, A., Bombardier, C., & Bouter, L. (2003) · Spine · doi:10.1097/01.brs.0000065484.95996.af · Cited by 2,180
INTRODUCING LEVELS OF EVIDENCE TO THE JOURNAL
Wright, J. G., Swiontkowski, M. F., & Heckman, J. D. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200301000-00001 · Cited by 1,284
Sala, F., Palandri, G., Basso, E., Lanteri, P., Deletis, V., Faccioli, F., & Bricolo, A. (2006) · Neurosurgery · doi:10.1227/01.neu.0000215948.97195.58 · Cited by 452
The use of “overall accuracy” to evaluate the validity of screening or diagnostic tests
Alberg, A. J., Park, J. W., Hager, B. W., Brock, M. V., & Diener-West, M. (2004) · Journal of General Internal Medicine · doi:10.1111/j.1525-1497.2004.30091.x · Cited by 295
THE NATIONAL JOINT REGISTRY FOR ENGLAND AND WALES
Horan, F. (2003) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.85b1.14063 · Cited by 259
Pajewski, T. N., Arlet, V., & Phillips, L. H. (2007) · European Spine Journal · doi:10.1007/s00586-007-0419-6 · Cited by 171
Prevention, identification, and treatment of perioperative spinal cord injury
Ahn, H., & Fehlings, M. G. (2008) · Neurosurgical FOCUS · doi:10.3171/foc.2008.25.11.e15 · Cited by 80
Self-citationEmerging drugs for spinal cord injury
Baptiste, D. C., & Fehlings, M. G. (2008) · Expert Opinion on Emerging Drugs · doi:10.1517/14728214.13.1.63 · Cited by 54
Self-citationMethods for the Systematic Reviews on Patient Safety During Spine Surgery
Dettori, J. R., Norvell, D. C., Dekutoski, M. B., Fisher, C. G., & Chapman, J. R. (2010) · Spine · doi:10.1097/brs.0b013e3181d70494 · Cited by 26
Self-citation
Metadata
- Authors
- Fehlings, M. G., Brodke, D. S., Norvell, D. C., & Dettori, J. R.
- Venue
- Spine
- Published
- 2010-04
- Volume
- 35
- Issue
- Supplement
- Pages
- S37-S46
- ISSN
- 0362-2436 (ISSN-L)
- OpenAlex
- W2006075274
- Cited by
- 312
- References
- 9
- FWCI
- 12.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Evidence for Intraoperative Neurophysiological Monitoring in Spine Surgery: Does It Make a Difference? https://app.cochat.ai/papers/10.1097/brs.0b013e3181d8338e
- The paper
- Fehlings, M. G., Brodke, D. S., Norvell, D. C., & Dettori, J. R. (2010). The Evidence for Intraoperative Neurophysiological Monitoring in Spine Surgery: Does It Make a Difference? Spine. https://doi.org/10.1097/brs.0b013e3181d8338e
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.