The DOI matches its Crossref record.
Complications in the Use of rhBMP-2 in PEEK Cages for Interbody Spinal Fusions
Abstract
STUDY DESIGN: All patients of spinal interbody fusion using polyetheretherketone (PEEK) cages and recombinant human bone morphogenetic protein (rhBMP)-2 performed over a 16-month period were reviewed. OBJECTIVE: To determine the suitability of PEEK cages when used in conjunction with rhBMP-2 in interbody spinal fusion. SUMMARY OF BACKGROUND DATA: Bone morphogenetic proteins are increasingly being used in spinal fusion to promote osteogenesis. PEEK is a semicrystalline aromatic polymer that is used as a structural spacer to maintain the disc and foraminal height. Their use has led to increased and predictable rates of fusion. However, not many reports of the adverse effects of their use are available. METHODS: Fifty-nine consecutive patients of interbody spinal fusion in the cervical or lumbar spine using a PEEK cage and rhBMP-2 were followed for an average of 26 months after surgery. A clinical examination and a record of Oswestry Disability Index, Visual Analog Scale for pain, and a pain diagram were performed preoperatively and at every follow-up visit. All patients had plain radiographs carried out to assess fusion. Ten patients of lumbar spine fusion were additionally evaluated with a computed tomography scan. RESULTS: All cases demonstrated an appreciable amount of new bone formation by 6 to 9 months in the cervical spine and by 9 to 12 months in the lumbar spine. End plate resorption was visible radiologically in all cervical spine fusions and majority of lumbar fusions. Cage migration was observed to occur maximally in patients with transforaminal lumbar interbody fusion and posterior lumbar interbody fusion. Disc space subsidence was seen in both cervical and lumbar arthrodesis with the latter showing a lesser incidence, but with a greater degree of collapse. CONCLUSIONS: PEEK cages and rhBMP-2 when used in spinal fusion give consistently good fusion rates. However, the early role of BMP in the resorptive phase may cause loosening, cage migration, and subsidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carragee, E. J., Hurwitz, E. L., & Weiner, B. K. (2011) · The Spine Journal · doi:10.1016/j.spinee.2011.04.023 · Cited by 1,395
A Review of the Clinical Side Effects of Bone Morphogenetic Protein-2
James, A. W., LaChaud, G., Shen, J., Asatrian, G., Nguyen, V., Zhang, X., Ting, K., & Soo, C. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0357 · Cited by 1,131
Complications with the use of bone morphogenetic protein 2 (BMP-2) in spine surgery
Tannoury, C. A., & An, H. S. (2014) · The Spine Journal · doi:10.1016/j.spinee.2013.08.060 · Cited by 433
Bone tissue regeneration: biology, strategies and interface studies
Ansari, M. (2019) · Progress in Biomaterials · doi:10.1007/s40204-019-00125-z · Cited by 340
Psychosocial Aspects of Disabling Musculoskeletal Pain
Vranceanu, A.-M., Barsky, A., & Ring, D. (2009) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.h.01512 · Cited by 304
Complications associated with single-level transforaminal lumbar interbody fusion
Rihn, J. A., Patel, R., Makda, J., Hong, J., Anderson, D. G., Vaccaro, A. R., Hilibrand, A. S., & Albert, T. J. (2009) · The Spine Journal · doi:10.1016/j.spinee.2009.04.004 · Cited by 286
Gel Scaffolds of BMP‐2‐Binding Peptide Amphiphile Nanofibers for Spinal Arthrodesis
Lee, S. S., Hsu, E. L., Mendoza, M., Ghodasra, J., Nickoli, M. S., Ashtekar, A., Polavarapu, M., Babu, J., Riaz, R. M., Nicolas, J. D., et al. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400129 · Cited by 183
Lubelski, D., Abdullah, K. G., Nowacki, A. S., Alvin, M. D., Steinmetz, M. P., Chakka, S., Li, Y., Gajewski, N., Benzel, E. C., & Mroz, T. E. (2013) · Journal of Neurosurgery: Spine · doi:10.3171/2012.11.spine12389 · Cited by 14
Metadata
- Authors
- Vaidya, R., Sethi, A., Bartol, S., Jacobson, M., Coe, C., & Craig, J. G.
- Venue
- Journal of Spinal Disorders & Techniques
- Published
- 2008-12
- Volume
- 21
- Issue
- 8
- Pages
- 557-562
- ISSN
- 1536-0652 (ISSN-L)
- OpenAlex
- W2007801151
- Cited by
- 194
- References
- 0
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.