Hemodynamic effect of different doses of fluids for a fluid challenge: A quasi-randomized controlled study.
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
Objective: The objectives of this study are to determine what is the minimal volume required to perform an effective fluid challenge and to investigate how different doses of IV fluids in an fluid challenge affect the changes in cardiac output and the proportion of responders and nonresponders. Design: Quasi-randomized controlled trial. Setting: Cardiothoracic ICU, tertiary university hospital. Patients: Eighty postcardiac surgery patients. Intervention: IV infusion of 1, 2, 3, or 4 mL/Kg (body weight) of crystalloid over 5 minutes. Measurements and Main Results: Mean systemic filling pressure measured using the transient stop-flow arm arterial-venous equilibrium pressure, arterial and central venous pressure, cardiac output (LiDCO plus ; LiDCO, Cambridge, United Kingdom), and heart rate. The groups were well matched with respect to demographic and baseline physiologic variables. The proportion of responders increased from 20% in the group of 1 mL/kg to 65% in the group of 4 mL/kg ( p = 0.04). The predicted minimal volume required for an fluid challenge was between 321 and 509 mL. Only 4 mL/Kg increases transient stop-flow arm arterial-venous equilibrium pressure beyond the limits of precision and was significantly associated with a positive response (odds ratio, 7.73; 95% CI, 1.78–31.04). Conclusion: The doses of fluids used for an fluid challenge modify the proportions of responders in postoperative patients. A dose of 4 mL/Kg increases transient stop-flow arm arterial-venous equilibrium pressure and reliably detects responders and nonresponders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In post-cardiac surgery patients, fluid challenges of 4 mL/kg compared to 1 to 3 mL/kg increased the sensitivity of detecting fluid responders and nonresponders based on measurement of CO (70).”
From Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021. (2021) · cites this paper as [70]
In the citing paper
“In post-cardiac surgery patients, fluid challenges of 4 ml/kg compared to 1–3 ml/kg increased the sensitivity of detecting fluid responders and non-responders based on measurement of CO [70].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple imputation using chained equations: Issues and guidance for practice
White, I. R., Royston, P., & Wood, A. M. (2011) · Statistics in Medicine · doi:10.1002/sim.4067 · Cited by 9,792
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Cecconi, M., Parsons, A. K., & Rhodes, A. (2011) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32834699cd · Cited by 244
Self-citationMean circulatory filling pressure: its meaning and measurement
Rothe, C. F. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.2.499 · Cited by 242
Mean Circulatory Filling Pressure Measured Immediately After Cessation of Heart Pumping
Guyton, A. C., Polizo, D., & Armstrong, G. G. (1954) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1954.179.2.261 · Cited by 242
Maas, J. J., Pinsky, M. R., de Wilde, R. B., de Jonge, E., & Jansen, J. R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea64 · Cited by 163
Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery
Verheij, J., van Lingen, A., Beishuizen, A., Christiaans, H. M. T., de Jong, J. R., Girbes, A. R. J., Wisselink, W., Rauwerda, H., Huybregts, M. A. J. M., & Groeneveld, A. B. J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0195-5 · Cited by 149
Treatment allocation methods in clinical trials: A review
Kalish, L. A., & Begg, C. B. (1985) · Statistics in Medicine · doi:10.1002/sim.4780040204 · Cited by 148
Weil, M. H., & Henning, R. J. (1979) · Anesthesia & Analgesia · doi:10.1213/00000539-197903000-00013 · Cited by 144
Mallat, J., Meddour, M., Durville, E., Lemyze, M., Pepy, F., Temime, J., Vangrunderbeeck, N., Tronchon, L., Thévenin, D., & Tavernier, B. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev222 · Cited by 135
Cited by
Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06506-y · Cited by 5,082
Self-citationSurviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021.
Evans, L., Rhodes, A., Alhazzani, W., Antonelli, M., Coopersmith, C. M., French, C., Machado, F. R., Mcintyre, L., Ostermann, M., Prescott, H. C., et al. (2021) · Critical Care Medicine · doi:10.1097/ccm.0000000000005337 · Cited by 2,935
Self-citationMalbrain, M. L. N. G., Van Regenmortel, N., Saugel, B., De Tavernier, B., Van Gaal, P.-J., Joannes-Boyau, O., Teboul, J.-L., Rice, T. W., Mythen, M., & Monnet, X. (2018) · Annals of Intensive Care · doi:10.1186/s13613-018-0402-x · Cited by 632
“The minimal fluid volume that is able to increase the backward pressure of venous return is 4 mL/kg [90].”
BackgroundPrediction of fluid responsiveness: an update
Monnet, X., Marik, P. E., & Teboul, J.-L. (2016) · Annals of Intensive Care · doi:10.1186/s13613-016-0216-7 · Cited by 600
Meyer, N. J., & Prescott, H. C. (2024) · New England Journal of Medicine · doi:10.1056/nejmra2403213 · Cited by 395
Metadata
- Authors
- Aya, H. D., Rhodes, A., Chis Ster, I., Fletcher, N., Grounds, R. M., & Cecconi, M.
- Affiliations
- St George's, University of London (GB)
- Institute of Infection and Immunity, St George’s University of London, London, United Kingdom.
- Venue
- Critical Care Medicine
- Published
- 2017-02
- Volume
- 45
- Issue
- 2
- Pages
- e161-e168
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2523582881
- Semantic Scholar
- d4c90050f400645e3870d32fac99c8a9e9c40959
- Cited by
- 121
- References
- 24
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 14 · 2023: 10 · 2022: 20 · 2021: 13 · 2020: 11 · 2019: 13 · 2018: 14 · 2017: 5
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Trauma, Hemostasis, Coagulopathy, Resuscitation
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Keywords
- fluid challenge, crystalloid infusion, fluid responsiveness, hemodynamic response, cardiac output
- MeSH terms
- Crystalloid Solutions, Aged, Blood Pressure, Cardiac Output, Dose-Response Relationship, Drug, Female, Fluid Therapy, Heart Rate, Hemodynamics, Humans, Infusions, Intravenous, Isotonic Solutions, Male, Middle Aged, Rehydration Solutions, Single-Blind Method
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamic effect of different doses of fluids for a fluid challenge: A quasi-randomized controlled study. https://app.cochat.ai/papers/10.1097/ccm.0000000000002067
- The paper
- Aya, H. D., Rhodes, A., Chis Ster, I., Fletcher, N., Grounds, R. M., & Cecconi, M. (2017). Hemodynamic effect of different doses of fluids for a fluid challenge: A quasi-randomized controlled study. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000002067
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.