Hemodynamic effect of different doses of fluids for a fluid challenge: A quasi-randomized controlled study.
The DOI matches its Crossref record; 23 of the 24 references it cites were found in a registry or an index.
Abstract
Objective: The objectives of this study are to determine what is the minimal volume required to perform an effective fluid challenge and to investigate how different doses of IV fluids in an fluid challenge affect the changes in cardiac output and the proportion of responders and nonresponders. Design: Quasi-randomized controlled trial. Setting: Cardiothoracic ICU, tertiary university hospital. Patients: Eighty postcardiac surgery patients. Intervention: IV infusion of 1, 2, 3, or 4 mL/Kg (body weight) of crystalloid over 5 minutes. Measurements and Main Results: Mean systemic filling pressure measured using the transient stop-flow arm arterial-venous equilibrium pressure, arterial and central venous pressure, cardiac output (LiDCO plus ; LiDCO, Cambridge, United Kingdom), and heart rate. The groups were well matched with respect to demographic and baseline physiologic variables. The proportion of responders increased from 20% in the group of 1 mL/kg to 65% in the group of 4 mL/kg ( p = 0.04). The predicted minimal volume required for an fluid challenge was between 321 and 509 mL. Only 4 mL/Kg increases transient stop-flow arm arterial-venous equilibrium pressure beyond the limits of precision and was significantly associated with a positive response (odds ratio, 7.73; 95% CI, 1.78–31.04). Conclusion: The doses of fluids used for an fluid challenge modify the proportions of responders in postoperative patients. A dose of 4 mL/Kg increases transient stop-flow arm arterial-venous equilibrium pressure and reliably detects responders and nonresponders.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In post-cardiac surgery patients, fluid challenges of 4 mL/kg compared to 1 to 3 mL/kg increased the sensitivity of detecting fluid responders and nonresponders based on measurement of CO (70).”
From Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock 2021. (2021) · cites this paper as [70]
In the citing paper
“In post-cardiac surgery patients, fluid challenges of 4 ml/kg compared to 1–3 ml/kg increased the sensitivity of detecting fluid responders and non-responders based on measurement of CO [70].”
From Surviving sepsis campaign: international guidelines for management of sepsis and septic shock 2021 (2021) · cites this paper as [70]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multiple imputation using chained equations: Issues and guidance for practice
White, I. R., Royston, P., & Wood, A. M. (2011) · Statistics in Medicine · doi:10.1002/sim.4067 · Cited by 9,792
Muller, L., Toumi, M., Bousquet, P.-J., Riu-Poulenc, B., Louart, G., Candela, D., Zoric, L., Suehs, C., de La Coussaye, J.-E., Molinari, N., et al. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318229a500 · Cited by 343
Cecconi, M., Parsons, A. K., & Rhodes, A. (2011) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e32834699cd · Cited by 244
Self-citationMean circulatory filling pressure: its meaning and measurement
Rothe, C. F. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.2.499 · Cited by 242
Mean Circulatory Filling Pressure Measured Immediately After Cessation of Heart Pumping
Guyton, A. C., Polizo, D., & Armstrong, G. G. (1954) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1954.179.2.261 · Cited by 242
Maas, J. J., Pinsky, M. R., de Wilde, R. B., de Jonge, E., & Jansen, J. R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e318265ea64 · Cited by 163
Cardiac response is greater for colloid than saline fluid loading after cardiac or vascular surgery
Verheij, J., van Lingen, A., Beishuizen, A., Christiaans, H. M. T., de Jong, J. R., Girbes, A. R. J., Wisselink, W., Rauwerda, H., Huybregts, M. A. J. M., & Groeneveld, A. B. J. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0195-5 · Cited by 149
Treatment allocation methods in clinical trials: A review
Kalish, L. A., & Begg, C. B. (1985) · Statistics in Medicine · doi:10.1002/sim.4780040204 · Cited by 148
Weil, M. H., & Henning, R. J. (1979) · Anesthesia & Analgesia · doi:10.1213/00000539-197903000-00013 · Cited by 144
Mallat, J., Meddour, M., Durville, E., Lemyze, M., Pepy, F., Temime, J., Vangrunderbeeck, N., Tronchon, L., Thévenin, D., & Tavernier, B. (2015) · British Journal of Anaesthesia · doi:10.1093/bja/aev222 · Cited by 135
Research works printed but not linked: 1
- 3. Cecconi M, Aya HD. What is a fluid challenge and how to perform it? In: Cannesson M, Pearse R, eds. Perioperative Hemodynamic Monitoring and Goal Directed Therapy: From Theory to Practice. Vol 1. Cambridge, United Kingdom: Cambridge University Press; 2014:213 - 223.
Cited by
Items 101–138 of 138
Perioperative infusion therapy
Skobelev, E. I., & Пасечник, И. Н. (2021) · Clinical nutrition and metabolism · doi:10.17816/clinutr81626
Can Passive Leg Raise Predict the Response to Fluid Resuscitation in ED?Preprint
Elwan, M. H., Roshdy, A., Elsharkawy, E., Eltahan, S. M., & Coats, T. (2022) · Research Square · doi:10.21203/rs.3.rs-1235100/v1
Yang, T., Weng, L., Jiang, W., Wang, C.-Y., Peng, J., Hu, X., Li, S., & Du, B. (2020) · Research Square · doi:10.21203/rs.3.rs-56714/v1
McAndrew, K., Cecconi, M., & Rhodes, A. (2019) · Lessons from the ICU · doi:10.1007/978-3-319-69269-2_11
Self-citationMean Systemic Filling Pressure Is an Old Concept but a New Tool for Fluid Management
Aya, H. D., & Cecconi, M. (2020) · Springer eBooks · doi:10.1007/978-3-030-48374-6_8
Self-citationCan passive leg raise predict the response to fluid resuscitation in ED?Preprint
Elwan, M. H., Roshdy, A., Elsharkawy, E., Eltahan, S. M., & Coats, T. (2022) · Research Square · doi:10.21203/rs.3.rs-1235100/v2
Messina, A., Colombo, D., Lionetti, G., Calabrò, L. A., Negri, K., Robba, C., Cammarota, G., Costantini, E., & Cecconi, M. (2022) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-022-00918-x
Self-citationMekeirele, M., Vanhonacker, D., & Malbrain, M. L. N. G. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-88271-2.00016-x
Schuster, H., Haller, B., Sancak, S., Erber, J., Schmid, R. M., Lahmer, T., & Rasch, S. (2023) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2023433
Septic Shock: First Fill the Pipes Up
(2023) · Journal of Acute Care · doi:10.5005/jp-journals-10089-0049
Estrategia integral de reanimación del paciente con sepsis y shock séptico
del Río-Carbajo, L., Olmo, J. N.-D., Fernández‐Ugidos, P., & Vidal, P. (2022) · Medicina Intensiva (English Edition) · doi:10.1016/j.medine.2022.02.025
Aya, H. D., & Cecconi, M. (2023) · Oxford University Press eBooks · doi:10.1093/med/9780198766438.003.0024
Self-citationTherapeutic Phases in Cardiogenic Shock—Part 1 Recognize/Rescue and Optimization
Lim, H. S. (2024) · Springer eBooks · doi:10.1007/978-3-031-64740-6_14
Restrepo, L. M., Arévalo, S. V. C., Miño–Bernal, J. F., & Alvarez, I. (2024) · Revista Colombiana de Nefrología · doi:10.22265/acnef.11.2.744
de Oliveira, P. S., Ramos, F. J. D. S., Tomotani, D. Y. V., Machado, F. R., & de Freitas, F. G. R. (2024) · Critical Care Science · doi:10.62675/2965-2774.20240073-pt
Pfortmueller, C. A., Dąbrowski, W., Wise, R., Regenmortel, N. V., & Malbrain, M. L. N. G. (2025) · Annals of Intensive Care · doi:10.1186/s13613-024-01403-1
Jayaprakash, N., Sarani, N., Nguyen, H. B., & Cannon, C. M. (2025) · Journal of the American College of Emergency Physicians Open · doi:10.1016/j.acepjo.2025.100080
The weight debate: Ideal versus total body weight for fluid resuscitation in septic shock
Bennett, A., Murray, B., Sikora, A. N., Reynolds, E., Branan, T. N., Bland, C. M., Hawkins, W. A., & Smith, S. E. (2025) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/zxaf313
Kříž, M., Nalos, M., Vintrych, P., Müller, J., Raděj, J., & Matějovič, M. (2025) · Anesteziologie a intenzivní medicína · doi:10.36290/aim.2025.047
Messina, A., Calabrò, L., Pugliese, L., Lulja, A., Sopuch, I. A., Rosalba, D., Morenghi, E., Glenn Hernández, P., Monnet, X., & Cecconi, M. (2022) · Figshare · doi:10.6084/m9.figshare.20115325
Self-citationPutko, K., Rasch, S., & München, T. U. (2022) · mediaTUM (Technical University of Munich)
Protocols for early detection and management of sepsis in intensive units
Σταύρου, Θ. Δ., & Σταύρου, Θ. Δ. (2025) · University of Thessaly Institutional Repository (University of Thessaly)
Castañeda, A. G. (2024) · Universidad Industrial de Santander
Rojas, F. J. R. (2023) · Investigative News in Education (Universidad de Costa Rica)
Yim, I. H. W. (2025) · University of Birmingham Institutional Research Archive (University of Birmingham)
Acuña, M. M. V. (2019) · Universidad Industrial de Santander
Upadhye, K. S., & Tayade, P. (2026) · Journal of Medical Sciences and Health · doi:10.46347/jmsh.v12.i2.26.54
Minimal haemodilution after rapid high-volume crystalloid infusion in healthy volunteers
Laugesen, L. T. F., Brabrand, M., & Biesenbach, P. (2026) · Postgraduate Medical Journal · doi:10.1093/postmj/qgag087
Choosongdet, T., Vutthikraivit, N., Assawaworrarit, P., Pachinburavan, M., & Sriprasat, T. (2026) · Research Square · doi:10.21203/rs.3.rs-10011705/v1
Chawathey, S. A., Solanki, S. L., & Divatia, J. V. (2026) · Indian Journal of Anaesthesia · doi:10.4103/ija.ija_557_26
Ocaña‐Alcober, C., Erroz, I. O., Palanca-Arias, D., López-Blanco, G., Ojembarrena, A. A., Suso, J. J. M., & Vázquez-Martínez, J. L. (2026) · Pediatric Research · doi:10.1038/s41390-026-05406-5
Cardiac output and stroke volume dissociate during fluid loading in conscious sheep
O'Brien, T., & Hahn, R. G. (2026) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.90145.2026
Precision fluid therapy in sepsis: fluid responsiveness vs. fluid tolerance
Araghi, A. (2026) · Frontiers in Medicine · doi:10.3389/fmed.2026.1980813
Joshi, M. P., Bhosale, S. J., Thanawala, I., & Kulkarni, A. P. (2026) · Journal of Anaesthesiology Clinical Pharmacology · doi:10.4103/joacp.joacp_313_25
В., П. К., А., В. Д., & Ю., К. М. (2025) · Russian Journal of Anesthesiology and Reanimatology
Metadata
- Authors
- Aya, H. D., Rhodes, A., Chis Ster, I., Fletcher, N., Grounds, R. M., & Cecconi, M.
- Affiliations
- St George's, University of London (GB)
- Institute of Infection and Immunity, St George’s University of London, London, United Kingdom.
- Venue
- Critical Care Medicine
- Published
- 2017-02
- Volume
- 45
- Issue
- 2
- Pages
- e161-e168
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2523582881
- Semantic Scholar
- d4c90050f400645e3870d32fac99c8a9e9c40959
- Cited by
- 121
- References
- 24
- Citations by year
- 2026: 7 · 2025: 11 · 2024: 14 · 2023: 10 · 2022: 20 · 2021: 13 · 2020: 11 · 2019: 13 · 2018: 14 · 2017: 5
- FWCI
- 12.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Critical Care Medicine (publishedVersion)
- PubMed (publishedVersion)
- St George's Online Research Archive (St George's University of London) (acceptedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Trauma, Hemostasis, Coagulopathy, Resuscitation
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Sepsis Diagnosis and Treatment
- Keywords
- fluid challenge, crystalloid infusion, fluid responsiveness, hemodynamic response, cardiac output
- MeSH terms
- Crystalloid Solutions, Aged, Blood Pressure, Cardiac Output, Dose-Response Relationship, Drug, Female, Fluid Therapy, Heart Rate, Hemodynamics, Humans, Infusions, Intravenous, Isotonic Solutions, Male, Middle Aged, Rehydration Solutions, Single-Blind Method
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.