Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 162

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Effects of High-Flow Nasal Cannula on the Work of Breathing in Patients Recovering From Acute Respiratory Failure*

Delorme, Mathieu, Bouchard, Pierre-Alexandre, Simon, Mathieu, Simard, Serge, Lellouche, François · 2017 · Critical Care Medicine

Abstract

Objectives: High-flow nasal cannula is increasingly used in the management of respiratory failure. However, little is known about its impact on respiratory effort, which could explain part of the benefits in terms of comfort and efficiency. This study was designed to assess the effects of high-flow nasal cannula on indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min) in adults. Design: A randomized controlled crossover study was conducted in 12 patients with moderate respiratory distress (i.e., after partial recovery from an acute episode, allowing physiologic measurements). Setting: Institut Universitaire de Cardiologie et de Pneumologie de Québec, QC, Canada. Subjects: Twelve adult patients with respiratory distress symptoms were enrolled in this study. Interventions: Four experimental conditions were evaluated: baseline with conventional oxygen therapy and high-flow nasal cannula at 20, 40, and 60 L/min. The primary outcomes were the indexes of respiratory effort (i.e., esophageal pressure variations, esophageal pressure-time product/min, and work of breathing/min). Secondary outcomes included tidal volume, respiratory rate, minute volume, dynamic lung compliance, inspiratory resistance, and blood gases. Measurements and Main Results: Esophageal pressure variations decreased from 9.8 (5.8–14.6) cm H 2 O at baseline to 4.9 (2.1–9.1) cm H 2 O at 60 L/min ( p = 0.035). Esophageal pressure-time product/min decreased from 165 (126–179) to 72 (54–137) cm H 2 O • s/min, respectively ( p = 0.033). Work of breathing/min decreased from 4.3 (3.5–6.3) to 2.1 (1.5–5.0) J/min, respectively ( p = 0.031). Respiratory pattern variables and capillary blood gases were not significantly modified between experimental conditions. Dynamic lung compliance increased from 38 (24–64) mL/cm H 2 O at baseline to 59 (43–175) mL/cm H 2 O at 60 L/min ( p = 0.007), and inspiratory resistance decreased from 9.6 (5.5–13.4) to 5.0 (1.0–9.1) cm H 2 O/L/s, respectively ( p = 0.07). Conclusions: High-flow nasal cannula, when set at 60 L/min, significantly reduces the indexes of respiratory effort in adult patients recovering from acute respiratory failure. This effect is associated with an improvement in respiratory mechanics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000002693

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 162

Metadata

Authors
Delorme, M., Bouchard, P.-A., Simon, M., Simard, S., & Lellouche, F.
Venue
Critical Care Medicine
Published
2017-12
Volume
45
Issue
12
Pages
1981-1988
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2753310877
Cited by
162
References
3
FWCI
11.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of High-Flow Nasal Cannula on the Work of Breathing in Patients Recovering From Acute Respiratory Failure*. https://app.cochat.ai/papers/10.1097/ccm.0000000000002693
The paper
Delorme, M., Bouchard, P.-A., Simon, M., Simard, S., & Lellouche, F. (2017). Effects of High-Flow Nasal Cannula on the Work of Breathing in Patients Recovering From Acute Respiratory Failure*. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000002693

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.