Cho, Kyung-Jae, Kwon, Oyeon, Kwon, Joon-myoung, Lee, Yeha, Park, Hyunho, Jeon, Ki-Hyun, Kim, Kyung-Hee, Park, Jinsik, Oh, Byung-Hee · 2020 · Critical Care Medicine
Cited by 88

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Objectives: As the performance of a conventional track and trigger system in a rapid response system has been unsatisfactory, we developed and implemented an artificial intelligence for predicting in-hospital cardiac arrest, denoted the deep learning-based early warning system. The purpose of this study was to compare the performance of an artificial intelligence-based early warning system with that of conventional methods in a real hospital situation. Design: Retrospective cohort study. Setting: This study was conducted at a hospital in which deep learning-based early warning system was implemented. Patients: We reviewed the records of adult patients who were admitted to the general ward of our hospital from April 2018 to March 2019. Interventions: The study population included 8,039 adult patients. A total 83 events of deterioration occurred during the study period. The outcome was events of deterioration, defined as cardiac arrest and unexpected ICU admission. We defined a true alarm as an alarm occurring within 0.5–24 hours before a deteriorating event. Measurements and Main Results: We used the area under the receiver operating characteristic curve, area under the precision-recall curve, number needed to examine, and mean alarm count per day as comparative measures. The deep learning-based early warning system (area under the receiver operating characteristic curve, 0.865; area under the precision-recall curve, 0.066) outperformed the modified early warning score (area under the receiver operating characteristic curve, 0.682; area under the precision-recall curve, 0.010) and reduced the number needed to examine and mean alarm count per day by 69.2% and 59.6%, respectively. At the same specificity, deep learning-based early warning system had up to 257% higher sensitivity than conventional methods. Conclusions: The developed artificial intelligence based on deep-learning, deep learning-based early warning system, accurately predicted deterioration of patients in a general ward and outperformed conventional methods. This study showed the potential and effectiveness of artificial intelligence in an rapid response system, which can be applied together with electronic health records. This will be a useful method to identify patients with deterioration and help with precise decision-making in daily practice.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0000000000004236

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 88

Metadata

Authors
Cho, K.-J., Kwon, O., Kwon, J.-M., Lee, Y., Park, H., Jeon, K.-H., Kim, K.-H., Park, J., & Oh, B.-H.
Venue
Critical Care Medicine
Published
2020-04
Volume
48
Issue
4
Pages
e285-e289
ISSN
0090-3493 (ISSN-L)
OpenAlex
W3006176871
Cited by
88
References
4
FWCI
10.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Detecting Patient Deterioration Using Artificial Intelligence in a Rapid Response System. https://app.cochat.ai/papers/10.1097/ccm.0000000000004236
The paper
Cho, K.-J., Kwon, O., Kwon, J.-M., Lee, Y., Park, H., Jeon, K.-H., Kim, K.-H., Park, J., & Oh, B.-H. (2020). Detecting Patient Deterioration Using Artificial Intelligence in a Rapid Response System. Critical Care Medicine. https://doi.org/10.1097/ccm.0000000000004236

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.