Prospective study of peripheral arterial catheter infection and comparison with concurrently sited central venous catheters*
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Peripheral arterial catheters are perceived as having low infective potential compared with other catheters and may be overlooked as a cause of catheter-related bloodstream infection. We aimed to measure colonization and rates of catheter-related bloodstream infection in arterial catheters, to investigate risk factors for arterial catheter colonization, and to compare arterial catheter infection rates with those in concurrently sited and managed central venous catheters. DESIGN: Prospective 24-month cohort study. SETTING: Eight-bed combined general intensive care and high-dependency unit of a 350-bed Australian teaching hospital. PATIENTS: Three hundred twenty-one arterial catheters in 252 adult and pediatric patients were observed for 1,082 catheter days, and 618 central venous catheters in 410 patients were observed for 4,040 catheter days. All catheters were inserted in, or presented to, the intensive care unit. Both arterial catheters and central venous catheters were inserted by trained personnel under aseptic conditions, and management was standardized. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: The incidence per 1,000 (95% confidence interval) catheter days of colonization (> or = 15 colonies) and catheter-related bloodstream infection was 15.7 (9.5-25.9) and 0.92 (0.13-6.44) for arterial catheters and 16.8 (13.3-21.3) and 2.23 (1.12-4.44) for central venous catheters. Arterial catheter colonization was not significantly different than that in central venous catheters (hazard ratio, 1.17; 95% confidence interval, 0.41-3.36; p = .77). Arterial catheter colonization increased with dwell time and was similar to central venous catheters over time. Femoral arterial catheters were colonized more often than radial arterial catheters (hazard ratio, 5.08; 95% confidence interval, 0.85, 30.3; p = .075), and colonization was significantly higher when the catheter was inserted in the operating theater or emergency department (hazard ratio, 4.45; 95% confidence interval, 1.42-13.9; p = .01) compared with the intensive care unit. CONCLUSIONS: The incidence of catheter-related bloodstream infection from arterial catheters was low. However, both arterial catheter colonization and rates of catheter-related bloodstream infection were similar to those in concurrently sited and identically managed central venous catheters. By inference, the arterial catheter should be accorded the same degree of importance as the central venous catheter as a potential source of sepsis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“Recent studies suggest that the risk of arterial CRBSI approaches that associated with short-term CVCs [63–65].”
BackgroundGuidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“Although a meta-analysis failed to discern a difference in rates of CRBSI among three sites of insertion (radial, femoral, and axillary) [342], colonization of catheters inserted in the femoral site occurs more often [158].”
InfluentialInfusion Nursing Standards of Practice
Gorski, L. A. (2007) · Journal of Infusion Nursing · doi:10.1097/01.nan.0000270673.13439.95 · Cited by 602
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Metadata
- Authors
- Koh, D. B. C., Gowardman, J. R., Rickard, C. M., Robertson, I. K., & Brown, A.
- Venue
- Critical Care Medicine
- Published
- 2008-02
- Volume
- 36
- Issue
- 2
- Pages
- 397-402
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2082308875
- Cited by
- 150
- References
- 1
- FWCI
- 24.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.