CoChat

Electrical impedance tomography compared with thoracic computed tomography during a slow inflation maneuver in experimental models of lung injury*

Wrigge, Hermann, Zinserling, Jörg, Muders, Thomas, Varelmann, Dirk, Günther, Ulf, von der Groeben, Cornelius, Magnusson, Anders, Hedenstierna, Göran, Putensen, Christian · 2008 · Critical Care Medicine
Cited by 206

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine the validity of functional electric impedance tomography to monitor regional ventilation distribution in experimental acute lung injury, and to develop a simple electric impedance tomography index detecting alveolar recruitment. DESIGN: Randomized prospective experimental study. SETTING: Academic research laboratory. SUBJECTS: Sixteen anesthetized, tracheotomized, and mechanically ventilated pigs. INTERVENTIONS: Acute lung injury was induced either by acid aspiration (direct acute lung injury) or by abdominal hypertension plus oleic acid injection (indirect acute lung injury) in ten pigs. Six pigs with normal lungs were studied as a control group and with endotracheal suction-related atelectasis. After 4 hrs of mechanical ventilation, a slow inflation was performed. MEASUREMENTS AND MAIN RESULTS: During slow inflation, simultaneous measurements of regional ventilation by electric impedance tomography and dynamic computed tomography were highly correlated in quadrants of a transversal thoracic plane (r2 = .63-.88, p < .0001, bias <5%) in both direct and indirect acute lung injury. Variability between methods was lower in direct than indirect acute lung injury (11 +/- 2% vs. 18 +/- 3%, respectively, p < .05). Electric impedance tomography indexes to detect alveolar recruitment were determined by mathematical curve analysis of regional impedance time curves. Empirical tests of different methods revealed that regional ventilation delay, that is, time delay of regional impedance time curve to reach a threshold, correlated well with recruited volume as measured by CT (r2 = .63). Correlation coefficients in subgroups were r2 = .71 and r2 = .48 in pigs with normal lungs with and without closed suction related atelectasis and r2 = .79 in pigs subject to indirect acute lung injury, respectively, whereas no significant correlation was found in pigs undergoing direct acute lung injury. CONCLUSIONS: Electric impedance tomography allows assessment of regional ventilation distribution and recruitment in experimental models of direct and indirect acute lung injury as well as normal lungs. Except for pigs with direct acute lung injury, regional ventilation delay determined during a slow inflation from impedance time curves appears to be a simple index for clinical monitoring of alveolar recruitment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181652edd

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Metadata

Authors
Wrigge, H., Zinserling, J., Muders, T., Varelmann, D., Günther, U., von der Groeben, C., Magnusson, A., Hedenstierna, G., & Putensen, C.
Venue
Critical Care Medicine
Published
2008-03
Volume
36
Issue
3
Pages
903-909
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1990985236
Cited by
206
References
3
FWCI
11.06
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.