Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Conventional markers of kidney function

Bagshaw, Sean M., Gibney, R T. Noel·2008·Critical Care Medicine

Abstract

Acute kidney injury remains a serious clinical problem for intensive care unit patients, and its incidence is rising. The detection and diagnosis of acute kidney injury in the intensive care unit currently require use of conventional markers of kidney function, specifically, serum creatinine and urea levels and, less frequently, other urinary tests. These conventional markers are familiar to clinicians and have long been used at the bedside. However, these markers are clearly not ideal, each has limitations, and none reflect real-time changes in glomerular filtration rate or a genuine acute injurious process to the kidney. More importantly, these conventional markers can contribute to delays in recognition of acute kidney injury and, hence, delays to appropriate supportive and therapeutic interventions. The early detection and diagnosis of acute kidney injury should be a clinical priority. A diagnostic test or panel of tests that are capable of evaluating aspects both of kidney function and acute injury are desperately needed in critical care nephrology. Cystatin C has been shown superior to conventional markers and may assume a greater role in intensive care unit patients for detecting both early changes in glomerular filtration rate and evidence of acute injury. Other newly characterized markers of kidney function or acute injury have the potential to revolutionized the field of critical care nephrology and greatly improve the supportive and therapeutic management of intensive care unit patients with acute kidney injury.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318168c613

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 170

Metadata

Authors
Bagshaw, S. M., & Gibney, R. T. N.
Venue
Critical Care Medicine
Published
2008-04
Volume
36
Issue
Suppl
Pages
S152-S158
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1984666428
Cited by
170
References
3
FWCI
9.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Conventional markers of kidney function. https://app.cochat.ai/papers/10.1097/ccm.0b013e318168c613
The paper
Bagshaw, S. M., & Gibney, R. T. N. (2008). Conventional markers of kidney function. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318168c613

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.