Validation of a predictive method for an accurate assessment of resting energy expenditure in medical mechanically ventilated patients*
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: Use comparison with indirect calorimetry to confirm the ability of our previously described equation to predict resting energy expenditure in mechanically ventilated patients. DESIGN: Prospective, validation study. SETTING: Eighteen-bed, medical intensive care unit at a teaching hospital. PATIENTS: All adult patients intubated >24 hrs were assessed for eligibility. Exclusion criteria were clinical situations that could contribute to erroneous calorimetric measurements. INTERVENTIONS: Resting energy expenditure was calculated using the original Harris-Benedict equations and those corrected for usual stress factors, the Swinamer equation, the Fusco equation, the Ireton-Jones equation, and our equation: resting energy expenditure (kcal/day) = 8 x weight (kg) + 14 x height (cm) + 32 x minute ventilation (L/min) + 94 x temperature (degrees C) - 4834. MEASUREMENTS AND MAIN RESULTS: Resting energy expenditure was measured by indirect calorimetry for the 45 included patients. Resting energy expenditure calculated with our predictive model correlated with the measured resting energy expenditure (r2 = .62, p < .0001), and Bland-Altman analysis showed a mean bias of -192 +/- 277 kcal/day, with limits of agreement ranging from -735 to 351 kcal/day. Resting energy expenditure calculated with the Harris-Benedict equations was more weakly correlated with measured resting energy expenditure (r2 = .41, p < .0001), with Bland-Altman analysis showing a mean bias of 279 +/- 346 kcal/day between them and the limits of agreement ranging from -399 to 957 kcal/day. Applying usual stress-correction factors to the Harris-Benedict equations generated wide variability, and the correlation with measured resting energy expenditure was poorer (r2 = .18, p < .0001), with Bland-Altman analysis showing a mean bias of -357 +/- 750 kcal/day and limits of agreement ranging from -1827 to 1113 kcal/day. The use of the Swinamer, Fusco, or Ireton-Jones predictive methods yielded weaker correlation between calculated and measured resting energy expenditure (r2 = .41, p < .0001; r2 = .38, p < .0001; r2 = .39, p < .0001, respectively) than our equation, and Bland-Altman analysis showed no improvement in agreement and variability between methods. CONCLUSIONS: The Faisy equation, based on static (height), less stable (weight), and dynamic biometric variables (temperature and minute ventilation), provided precise and unbiased resting energy expenditure estimations in mechanically ventilated patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Weijs, P. J., Looijaard, W. G., Beishuizen, A., Girbes, A. R., & Oudemans-van Straaten, H. M. (2014) · Critical Care · doi:10.1186/s13054-014-0701-z · Cited by 358
“This means that a standard prescription of estimated energy requirement by Harris-Benedict equation plus 30% is an inaccurate predictor of energy requirements in ICU patients, as has been reported before [5,28,29].”
Indirect calorimetry in nutritional therapy. A position paper by the ICALIC study group
Oshima, T., Berger, M. M., De Waele, E., Guttormsen, A. B., Heidegger, C.-P., Hiesmayr, M., Singer, P., Wernerman, J., & Pichard, C. (2017) · Clinical Nutrition · doi:10.1016/j.clnu.2016.06.010 · Cited by 283
“Although much effort has been made to create predictive equations adapted to the clinical evolution of acute illness [48], IC remains the gold standard to measure EE [3,19].”
BackgroundFaisy, C., Lerolle, N., Dachraoui, F., Savard, J.-F., Abboud, I., Tadie, J.-M., & Fagon, J.-Y. (2008) · British Journal of Nutrition · doi:10.1017/s0007114508055669 · Cited by 179
Self-citationTatucu‐Babet, O. A., Ridley, E. J., & Tierney, A. C. (2016) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607114567898 · Cited by 133
“adequate amounts of nutrition versus those receiving 77% of energy targets.(10) Overfeeding has similarly been linked with negative health outcomes such as azotaemia,(11) increased MV time,(12) and altered hepatic function.”
BackgroundMethodInfluential
Metadata
- Authors
- Savard, J.-F., Faisy, C., Lerolle, N., Guerot, E., Diehl, J.-L., & Fagon, J.-Y.
- Venue
- Critical Care Medicine
- Published
- 2008-04
- Volume
- 36
- Issue
- 4
- Pages
- 1175-1183
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2029844498
- Cited by
- 53
- References
- 1
- FWCI
- 3.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.