Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 190

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Immortal time bias in critical care research: Application of time-varying Cox regression for observational cohort studies*

Open access
Shintani, Ayumi K., Girard, Timothy D., Eden, Svetlana K., Arbogast, Patrick G., Moons, Karel G. M., Ely, E Wesley · 2009 · Critical Care Medicine

Abstract

OBJECTIVES: To examine the bias introduced by using time-fixed methodology to analyze the effects of a time-varying exposure incurred in the intensive care unit. DESIGN: Prospective cohort and Monte Carlo simulation studies. SETTING: Medical and coronary intensive care units in a university hospital. PATIENTS: A total of 224 mechanically ventilated patients. METHODS: Part I was a case study analyzing the association between delirium in the intensive care unit (exposure variable) and outcomes (intensive care unit length of stay and 6-mo mortality) in a prospective cohort study. Part II was a Monte Carlo simulation generating 16,000 data sets wherein the true associations between delirium and outcomes were known before analysis. In both parts, we assessed associations between delirium in the intensive care unit and outcomes (intensive care unit length of stay and mortality), using time-fixed vs. time-varying Cox regression methodology. MEASUREMENTS AND MAIN RESULTS: In the case study, delirium analyzed as a time-fixed variable was associated with a delayed intensive care unit discharge (adjusted hazard ratio = 1.9, 95% confidence interval, 1.3-2.7, p < .001), but no association was noted using a time-varying method (adjusted hazard ratio = 1.1, 95% confidence interval = 0.7-1.6, p = .70). Alternatively, delirium analyzed as a time-fixed variable was not associated with 6-mo mortality (adjusted hazard ratio = 2.9, 95% confidence interval, 0.9-5.0, p = .09), whereas delirium analyzed as a time-varying variable was associated with increased mortality (adjusted hazard ratio = 3.2, 95% confidence interval, 1.4-7.7, p = .008). In the simulation study, time-fixed methods produced erroneous results in 97.1% of the data sets with no true association; time-varying methods produced erroneous results in only 3.7%. Similarly, time-fixed methods produced biased results when a true association was present, whereas time-varying methods produced accurate results. CONCLUSIONS: Studies using a time-fixed analytic approach to understand relationships between exposures and clinical outcomes can result in considerable bias when the variables overlap temporally in occurrence. Those conducting such studies, and clinicians reading them, should ensure that time-varying exposures are correctly analyzed to avoid biased conclusions.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181b7fbbb

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 190

Metadata

Authors
Shintani, A. K., Girard, T. D., Eden, S. K., Arbogast, P. G., Moons, K. G. M., & Ely, E. W.
Venue
Critical Care Medicine
Published
2009-11
Volume
37
Issue
11
Pages
2939-2945
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2026094606
Cited by
190
References
3
FWCI
5.19
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Immortal time bias in critical care research: Application of time-varying Cox regression for observational cohort studies*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3181b7fbbb
The paper
Shintani, A. K., Girard, T. D., Eden, S. K., Arbogast, P. G., Moons, K. G. M., & Ely, E. W. (2009). Immortal time bias in critical care research: Application of time-varying Cox regression for observational cohort studies*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3181b7fbbb

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.