Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 211

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Patient-ventilator interaction during pressure support ventilation and neurally adjusted ventilatory assist*

Spahija, Jadranka, de Marchie, Michel, Albert, Martin, Bellemare, Patrick, Delisle, Stéphane, Beck, Jennifer, Sinderby, Christer · 2010 · Critical Care Medicine

Abstract

OBJECTIVE: To compare the effect of pressure support ventilation and neurally adjusted ventilatory assist on breathing pattern, patient-ventilator synchrony, diaphragm unloading, and gas exchange. Increasing the level of pressure support ventilation can increase tidal volume, reduce respiratory rate, and lead to delayed ventilator triggering and cycling. Neurally adjusted ventilatory assist uses diaphragm electrical activity to control the timing and pressure of assist delivery and is expected to enhance patient-ventilator synchrony. DESIGN: Prospective, comparative, crossover study. SETTING: Adult critical care unit in a tertiary university hospital. PATIENTS: Fourteen nonsedated mechanically ventilated patients (n = 12 with chronic obstructive pulmonary disease). INTERVENTIONS: Patients were ventilated for 10-min periods, using two pressure support ventilation levels (lowest tolerable and +7 cm H2O higher) and two neurally adjusted ventilatory assist levels (same peak pressures and external positive end-expiratory pressure as with pressure support ventilation), delivered in a randomized order. MEASUREMENTS AND MAIN RESULTS: Diaphragm electrical activity, respiratory pressures, air flow, volume, neural and ventilator respiratory rates, and arterial blood gases were measured. Peak pressures were 17 +/- 6 cm H2O and 24 +/- 6 cm H2O and 19 +/- 5 cm H2O and 24 +/- 6 cm H2O with high and low pressure support ventilation and neurally adjusted ventilatory assist, respectively. The breathing pattern was comparable with pressure support ventilation and neurally adjusted ventilatory assist during low assist; during higher assist, larger tidal volumes (p = .003) and lower breathing frequencies (p = .008) were observed with pressure support ventilation. Increasing the assist increased cycling delays only with pressure support ventilation (p = .003). Compared with pressure support ventilation, neurally adjusted ventilatory assist reduced delays of ventilator triggering (p < .001 for low and high assist) and cycling (high assist: p = .004; low assist: p = .04), and abolished wasted inspiratory efforts observed with pressure support ventilation in six subjects. The diaphragm electrical activity and pressure-time product for ventilator triggering were lower with neurally adjusted ventilatory assist (p = .005 and p = .02, respectively; analysis of variance). Arterial blood gases were similar with both modes. CONCLUSIONS: Neurally adjusted ventilatory assist can improve patient-ventilator synchrony by reducing the triggering and cycling delays, especially at higher levels of assist, at the same time preserving breathing and maintaining blood gases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181cb0d7b

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 211

Metadata

Authors
Spahija, J., de Marchie, M., Albert, M., Bellemare, P., Delisle, S., Beck, J., & Sinderby, C.
Venue
Critical Care Medicine
Published
2010-02
Volume
38
Issue
2
Pages
518-526
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1981435384
Cited by
211
References
1
FWCI
18.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.