CoChat

A multifaceted program to prevent ventilator-associated pneumonia: Impact on compliance with preventive measures*

Bouadma, Lila, Mourvillier, Bruno, Deiler, Véronique, Le Corre, Bertrand, Lolom, Isabelle, Régnier, Bernard, Wolff, Michel, Lucet, Jean-Christophe · 2010 · Critical Care Medicine
Cited by 151

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To determine the effect of a 2-yr multifaceted program aimed at preventing ventilator-acquired pneumonia on compliance with eight targeted preventive measures. DESIGN: Pre- and postintervention observational study. SETTING: A 20-bed medical intensive care unit in a teaching hospital. PATIENTS: A total of 1649 ventilator-days were observed. INTERVENTIONS: The program involved all healthcare workers and included a multidisciplinary task force, an educational session, direct observations with performance feedback, technical improvements, and reminders. It focused on eight targeted measures based on well-recognized published guidelines, easily and precisely defined acts, and directly concerned healthcare workers' bedside behavior. Compliance assessment consisted of five 4-wk periods (before the intervention and 1 month, 6 months, 12 months, and 24 months thereafter). MEASUREMENTS AND MAIN RESULTS: Hand-hygiene and glove-and-gown use compliances were initially high (68% and 80%) and remained stable over time. Compliance with all other preventive measures was initially low and increased steadily over time (before 2-yr level, p < .0001): backrest elevation (5% to 58%) and tracheal cuff pressure maintenance (40% to 89%), which improved after simple technical equipment implementation; orogastric tube use (52% to 96%); gastric overdistension avoidance (20% to 68%); good oral hygiene (47% to 90%); and nonessential tracheal suction elimination (41% to 92%). To assess overall performance of the last six preventive measures, using ventilator-days as the unit of analysis, a composite score for preventive measures applied (range, 0-6) was developed. The median (interquartile range) composite scores for the five successive assessments were 2 (1-3), 4 (3-5), 4 (4-5), 5 (4-6), and 5 (4-6) points; they increased significantly over time (p < .0001). Ventilator-acquired pneumonia prevalence rate decreased by 51% after intervention (p < .0001). CONCLUSIONS: Our active, long-lasting program for preventing ventilator-acquired pneumonia successfully increased compliance with preventive measures directly dependent on healthcare workers' bedside performance. The multidimensional framework was critical for this marked, progressive, and sustained change.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e3181ce21af

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Bouadma, L., Mourvillier, B., Deiler, V., Le Corre, B., Lolom, I., Régnier, B., Wolff, M., & Lucet, J.-C.
Venue
Critical Care Medicine
Published
2010-03
Volume
38
Issue
3
Pages
789-796
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2025331047
Cited by
151
References
6
FWCI
12.21
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.