Limiting ventilator-induced lung injury through individual electronic medical record surveillance*
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
BACKGROUND: To improve the safety of ventilator care and decrease the risk of ventilator-induced lung injury, we designed and tested an electronic algorithm that incorporates patient characteristics and ventilator settings, allowing near-real-time notification of bedside providers about potentially injurious ventilator settings. METHODS: Electronic medical records of consecutive patients who received invasive ventilation were screened in three Mayo Clinic Rochester intensive care units. The computer system alerted bedside providers via the text paging notification about potentially injurious ventilator settings. Alert criteria included a Pao2/Fio2 ratio of <300 mm Hg, free text search for the words "edema" or "bilateral + infiltrates" on the chest radiograph report, a tidal volume of >8 mL/kg predicted body weight (based on patient gender and height), a plateau pressure of >30 cm H2O, and a peak airway pressure of >35 cm H2O. Respiratory therapists answered a brief online satisfaction survey. Ventilator-induced lung injury risk was compared before and after the introduction of ventilator-induced lung injury alert. FINDINGS: The prevalence of acute lung injury was 42% (n = 490) among 1,159 patients receiving >24 hrs of invasive ventilation. The system sent 111 alerts for 80 patients, with a positive predictive value of 59%. The exposure to potentially injurious ventilation decreased after the intervention from 40.6 ± 74.6 hrs to 26.9 ± 77.3 hrs (p = .004). INTERPRETATIONS: Electronic medical record surveillance of mechanically ventilated patients accurately detects potentially injurious ventilator settings and is able to influence bedside practice at moderate costs. Its implementation is associated with decreased patient exposure to potentially injurious mechanical ventilation settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence and Outcomes of Acute Lung Injury
Rubenfeld, G. D., Caldwell, E., Peabody, E., Weaver, J., Martin, D. P., Neff, M., Stern, E. J., & Hudson, L. D. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050333 · Cited by 3,684
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654 · cited 7×
“Although the best ventilator practice remains controversial, a recent metaanalysis of clinical trials identified a threshold for VT of 7.7 mL/kg PBW and a plateau pressure of 30 cm H2O to be associated with improved patient outcome (5).”
MethodInfluentialComparison of Two Fluid-Management Strategies in Acute Lung Injury
(2006) · New England Journal of Medicine · doi:10.1056/nejmoa062200 · Cited by 3,538
The acute respiratory distress syndrome
Matthay, M. A., Ware, L. B., & Zimmerman, G. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci60331 · Cited by 1,706
Cited by
Churpek, M. M., Yuen, T. C., Winslow, C., Meltzer, D. O., Kattan, M. W., & Edelson, D. P. (2016) · Critical Care Medicine · doi:10.1097/ccm.0000000000001571 · Cited by 638
Guidelines on the management of acute respiratory distress syndrome
Griffiths, M. J. D., McAuley, D. F., Perkins, G. D., Barrett, N., Blackwood, B., Boyle, A., Chee, N., Connolly, B., Dark, P., Finney, S., et al. (2019) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2019-000420 · Cited by 514
Lee, T. C., Shah, N. U., Haack, A., & Baxter, S. L. (2020) · Informatics · doi:10.3390/informatics7030025 · Cited by 133
“[29] Interruptive Bedside alert via text paging “Because the majority of patients are treated with appropriate ventilator settings, unnecessary interruptions with new alert paradigms could have a detrimental effect on performance.”
BackgroundAhmed, A., Vairavan, S., Akhoundi, A., Wilson, G., Chiofolo, C., Chbat, N., Cartin-Ceba, R., Li, G., & Kashani, K. (2015) · Journal of Critical Care · doi:10.1016/j.jcrc.2015.05.007 · Cited by 73
Self-citationBenthin, C., Pannu, S., Khan, A., & Gong, M. (2016) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201603-172bc · Cited by 18
“Inacute care settings, e-alert use has been limited to single-center reports (2, 9, 10).”
Background
Metadata
- Authors
- Herasevich, V., Tsapenko, M., Kojicic, M., Ahmed, A., Kashyap, R., Venkata, C., Shahjehan, K., Thakur, S. J., Pickering, B. W., Zhang, J., Hubmayr, R. D., & Gajic, O.
- Venue
- Critical Care Medicine
- Published
- 2011-01
- Volume
- 39
- Issue
- 1
- Pages
- 34-39
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2054576479
- Cited by
- 92
- References
- 4
- FWCI
- 4.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.