CoChat

Comparison of four different vascular occlusion tests for assessing reactive hyperemia using near-infrared spectroscopy

Mayeur, Claire, Campard, Sébastien, Richard, Christian, Teboul, Jean-Louis · 2011 · Critical Care Medicine
Cited by 91

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To compare data gathered via four different types of vascular occlusion test (VOT) by using near-infrared spectroscopy. The data may support a standardized method to appropriately measure the postischemic recovery slope, which is currently emphasized as a quantitative marker of the microvascular reserve in septic patients. DESIGN: Prospective study. SETTING: Medical intensive care unit of a university hospital. PATIENTS AND MEASUREMENTS: In 20 healthy volunteers and in 20 septic shock patients, we measured muscle tissue oxygen saturation at the thenar eminence by using near-infrared spectroscopy and performed four different vascular occlusion tests in a random order. A pneumatic cuff was placed around either the upper arm (A) or the forearm (FA). Cuff inflation was maintained either during 3 mins (VOT(A3min) and VOT(FA3min)) or until muscle tissue oxygen saturation decreased to 40% (VOT(A40%) and VOT(FA40%)). RESULTS: In volunteers: 1) During VOT(A3min) and VOT(FA3min), the minimal muscle tissue oxygen saturation was significantly higher than 40% (52% ± 10% and 54% ± 6%, respectively), and 2) the muscle tissue oxygen saturation recovery slopes were steeper with VOT(A40%) and VOT(FA40%) than with VOT(A3min) and VOT(FA3min), respectively. Considering the pooled data obtained during VOT(A3min) and VOT(FA3min) (n = 40), recovery slope negatively correlated with minimal muscle tissue oxygen saturation in volunteers (r² = .46, p < .0001) as in septic patients (r² = .34, p = .0001). Considering the pooled data obtained during 40% VOTs, the recovery slope did not correlate with ischemic time in either group. The overlap of recovery slopes between volunteers and septic patients was small for both 40% VOTs but large for both 3-min occlusion VOTs. CONCLUSION: The comparison of recovery slopes between volunteers and septic patients and the fact that the recovery slope was influenced by the extent of muscle tissue oxygen saturation decrease during ischemia and not by the ischemic time both support the use of a fixed minimal muscle tissue oxygen saturation target (40%) over the use of a fixed ischemic time (3 mins) for assessing reactive hyperemia by using near-infrared spectroscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318206d256

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Mayeur, C., Campard, S., Richard, C., & Teboul, J.-L.
Venue
Critical Care Medicine
Published
2011-04
Volume
39
Issue
4
Pages
695-701
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2029158148
Cited by
91
References
2
FWCI
5.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.