Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients*
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective: To determine whether noninvasive hemoglobin measurement by Pulse CO-Oximetry could provide clinically acceptable absolute and trend accuracy in critically ill patients, compared to other invasive methods of hemoglobin assessment available at bedside and the gold standard, the laboratory analyzer. Design: Prospective study. Setting: Surgical intensive care unit of a university teaching hospital. Patients: Sixty-two patients continuously monitored with Pulse CO-Oximetry (Masimo Radical-7). Interventions: None. Measurements and Results: Four hundred seventy-one blood samples were analyzed by a point-of-care device (HemoCue 301), a satellite lab CO-Oximeter (Siemens RapidPoint 405), and a laboratory hematology analyzer (Sysmex XT-2000i), which was considered the reference device. Hemoglobin values reported from the invasive methods were compared to the values reported by the Pulse CO-Oximeter at the time of blood draw. When the case-to-case variation was assessed, the bias and limits of agreement were 0.0 ± 1.0 g/dL for the Pulse CO-Oximeter, 0.3 ± 1.3g/dL for the point-of-care device, and 0.9 ± 0.6 g/dL for the satellite lab CO-Oximeter compared to the reference method. Pulse CO-Oximetry showed similar trend accuracy as satellite lab CO-Oximetry, whereas the point-of-care device did not appear to follow the trend of the laboratory analyzer as well as the other test devices. Conclusion: When compared to laboratory reference values, hemoglobin measurement with Pulse CO-Oximetry has absolute accuracy and trending accuracy similar to widely used, invasive methods of hemoglobin measurement at bedside. Hemoglobin measurement with pulse CO-Oximetry has the additional advantages of providing continuous measurements, noninvasively, which may facilitate hemoglobin monitoring in the intensive care unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vincent, J. L., Moreno, R., Takala, J., Willatts, S., De Mendonça, A., Bruining, H., Reinhart, C. K., Suter, P. M., & Thijs, L. G. (1996) · Intensive Care Medicine · doi:10.1007/bf01709751 · Cited by 11,674
Le Gall, J.-R. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.270.24.2957 · Cited by 7,773 · cited 1×
“Simplified Acute Physiology Score II (9) and”
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
Passing, H., & Bablok, W. (1983) · cclm · doi:10.1515/cclm.1983.21.11.709 · Cited by 1,513
Rodriguez, R. M., Corwin, H. L., Gettinger, A., Corwin, M. J., Gubler, D., & Pearl, R. G. (2001) · Journal of Critical Care · doi:10.1053/jcrc.2001.21795 · Cited by 282 · cited 1×
“Blood loss from phlebotomy causes iatrogenic anemia, with over 90% of ICU patients becoming anemic by the third day of ICU admission (6).”
Background
Cited by
Allardet-Servent, J., Lebsir, M., Dubroca, C., Fabrigoule, M., Jordana, S., Signouret, T., Castanier, M., Thomas, G., Soundaravelou, R., Lepidi, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0169593 · Cited by 64
Point-of-care testing: where is the evidence? A systematic survey
Pecoraro, V., Germagnoli, L., & Banfi, G. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0386 · Cited by 56
New technologies in pediatric anesthesia
Holtby, H., Skowno, J. J., Kor, D. J., Flick, R. P., & Uezono, S. (2012) · Pediatric Anesthesia · doi:10.1111/pan.12007 · Cited by 35
Metadata
- Authors
- Frasca, D., Dahyot-Fizelier, C., Catherine, K., Levrat, Q., Debaene, B., & Mimoz, O.
- Venue
- Critical Care Medicine
- Published
- 2011-10
- Volume
- 39
- Issue
- 10
- Pages
- 2277-2282
- ISSN
- 0090-3493 (ISSN-L)
- OpenAlex
- W2054168240
- Cited by
- 178
- References
- 5
- FWCI
- 22.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients*. https://app.cochat.ai/papers/10.1097/ccm.0b013e3182227e2d
- The paper
- Frasca, D., Dahyot-Fizelier, C., Catherine, K., Levrat, Q., Debaene, B., & Mimoz, O. (2011). Accuracy of a continuous noninvasive hemoglobin monitor in intensive care unit patients*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e3182227e2d
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.