CoChat

Tidal recruitment assessed by electrical impedance tomography and computed tomography in a porcine model of lung injury*

Muders, Thomas, Luepschen, Henning, Zinserling, Jörg, Greschus, Susanne, Fimmers, Rolf, Guenther, Ulf, Buchwald, Miriam, Grigutsch, Daniel, Leonhardt, Steffen, Putensen, Christian, Wrigge, Hermann · 2012 · Critical Care Medicine
Cited by 169

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVES: To determine the validity of electrical impedance tomography to detect and quantify the amount of tidal recruitment caused by different positive end-expiratory pressure levels in a porcine acute lung injury model. DESIGN: Randomized, controlled, prospective experimental study. SETTING: Academic research laboratory. SUBJECTS: Twelve anesthetized and mechanically ventilated pigs. INTERVENTIONS: Acute lung injury was induced by central venous oleic acid injection and abdominal hypertension in seven animals. Five healthy pigs served as control group. Animals were ventilated with positive end-expiratory pressure of 0, 5, 10, 15, 20, and 25 cm H2O, respectively, in a randomized order. MEASUREMENTS AND MAIN RESULTS: At any positive end-expiratory pressure level, electrical impedance tomography was obtained during a slow inflation of 12 mL/kg of body weight. Regional-ventilation-delay indices quantifying the time until a lung region reaches a certain amount of impedance change were calculated for lung quadrants and for every single electrical impedance tomography pixel, respectively. Pixel-wise calculated regional-ventilation-delay indices were plotted in a color-coded regional-ventilation-delay map. Regional-ventilation-delay inhomogeneity that quantifies heterogeneity of ventilation time courses was evaluated by calculating the scatter of all pixel-wise calculated regional-ventilation-delay indices. End-expiratory and end-inspiratory computed tomography scans were performed at each positive end-expiratory pressure level to quantify tidal recruitment of the lung. Tidal recruitment showed a moderate inter-individual (r = .54; p < .05) and intra-individual linear correlation (r = .46 up to r = .73 and p < .05, respectively) with regional-ventilation-delay obtained from lung quadrants. Regional-ventilation-delay inhomogeneity was excellently correlated with tidal recruitment intra- (r = .90 up to r = .99 and p < .05, respectively) and inter-individually (r = .90; p < .001). CONCLUSIONS: Regional-ventilation-delay can be noninvasively measured by electrical impedance tomography during a slow inflation of 12 mL/kg of body weight and visualized using ventilation delay maps. Our experimental data suggest that the impedance tomography-based analysis of regional-ventilation-delay inhomogeneity provides a good estimate of the amount of tidal recruitment and may be useful to individualize ventilatory settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318236f452

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 169

Metadata

Authors
Muders, T., Luepschen, H., Zinserling, J., Greschus, S., Fimmers, R., Guenther, U., Buchwald, M., Grigutsch, D., Leonhardt, S., Putensen, C., & Wrigge, H.
Venue
Critical Care Medicine
Published
2012-03
Volume
40
Issue
3
Pages
903-911
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2334749998
Cited by
169
References
6
FWCI
6.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.