A controlled trial of electronic automated advisory vital signs monitoring in general hospital wards*

Bellomo, Rinaldo, Ackerman, Michael, Bailey, Michael, Beale, Richard, Clancy, Greg, Danesh, Valerie, Hvarfner, Andreas, Jimenez, Edgar, Konrad, David, Lecardo, Michele, Pattee, Kimberly S., Ritchie, Josephine, Sherman, Kathie, Tangkau, Peter·2012·Critical Care Medicine

Abstract

OBJECTIVES: Deteriorating ward patients are at increased risk. Electronic automated advisory vital signs monitors may help identify such patients and improve their outcomes. SETTING: A total of 349 beds, in 12 general wards in ten hospitals in the United States, Europe, and Australia. PATIENTS: Cohort of 18,305 patients. DESIGN: Before-and-after controlled trial. INTERVENTION: We deployed electronic automated advisory vital signs monitors to assist in the acquisition of vital signs and calculation of early warning scores. We assessed their effect on frequency, type, and treatment of rapid response team calls; survival to hospital discharge or to 90 days for rapid response team call patients; overall type and number of serious adverse events and length of hospital stay. MEASUREMENTS AND MAIN RESULTS: We studied 9,617 patients before (control) and 8,688 after (intervention) deployment of electronic automated advisory vital signs monitors. Among rapid response team call patients, intervention was associated with an increased proportion of calls secondary to abnormal respiratory vital signs (from 21% to 31%; difference [95% confidence interval] 9.9 [0.1-18.5]; p=.029). Survival immediately after rapid response team treatment and survival to hospital discharge or 90 days increased from 86% to 92% (difference [95% confidence interval] 6.3 [0.0-12.6]; p=.04). Intervention was also associated with a decrease in median length of hospital stay in all patients (unadjusted p<.0001; adjusted p=.09) and more so in U.S. patients (from 3.4 to 3.0 days; unadjusted p<.0001; adjusted ratio [95% confidence interval] 1.03 [1.00-1.06]; p=.026). The time required to complete and record a set of vital signs decreased from 4.1±1.3 mins to 2.5±0.5 mins (difference [95% confidence interval] 1.6 [1.4-1.8]; p<.0001). CONCLUSIONS: Deployment of electronic automated advisory vital signs monitors was associated with an improvement in the proportion of rapid response team-calls triggered by respiratory criteria, increased survival of patients receiving rapid response team calls, and decreased time required for vital signs measurement and recording (NCT01197326).

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e318255d9a0

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 228

Metadata

Authors
Bellomo, R., Ackerman, M., Bailey, M., Beale, R., Clancy, G., Danesh, V., Hvarfner, A., Jimenez, E., Konrad, D., Lecardo, M., Pattee, K. S., Ritchie, J., Sherman, K., & Tangkau, P.
Venue
Critical Care Medicine
Published
2012-08
Volume
40
Issue
8
Pages
2349-2361
ISSN
0090-3493 (ISSN-L)
OpenAlex
W1968206948
Cited by
228
References
0
FWCI
22.85
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A controlled trial of electronic automated advisory vital signs monitoring in general hospital wards*. https://app.cochat.ai/papers/10.1097/ccm.0b013e318255d9a0
The paper
Bellomo, R., Ackerman, M., Bailey, M., Beale, R., Clancy, G., Danesh, V., Hvarfner, A., Jimenez, E., Konrad, D., Lecardo, M., Pattee, K. S., Ritchie, J., Sherman, K., & Tangkau, P. (2012). A controlled trial of electronic automated advisory vital signs monitoring in general hospital wards*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e318255d9a0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.