Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 297

The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.

A New Severity of Illness Scale Using a Subset of Acute Physiology and Chronic Health Evaluation Data Elements Shows Comparable Predictive Accuracy*

Johnson, Alistair E. W., Kramer, Andrew A., Clifford, Gari D. · 2013 · Critical Care Medicine

Abstract

OBJECTIVES: Severity of illness scores have gained considerable interest for their use in predicting outcomes such as mortality and length of stay. The most sophisticated scoring systems require the collection of numerous physiologic measurements, making their use in real-time difficult. A severity of illness score based on a few parameters that can be captured electronically would be of great benefit. Using a machine-learning technique known as particle swarm optimization, we attempted to reduce the number of physiologic parameters collected in the Acute Physiology, Age, and Chronic Health Evaluation IV system without losing predictive accuracy. DESIGN: Retrospective cohort study of ICU admissions from 2007 to 2011. SETTING: Eighty-six ICUs at 49 U.S. hospitals where an Acute Physiology, Age, and Chronic Health Evaluation IV system had been installed. PATIENTS: 81,087 admissions, of which 72,474 did not have any missing values. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Machine-learning algorithms were used to come up with the minimal set of variables that were capable of yielding an accurate severity of illness score: the Oxford Acute Severity of Illness Score. Predictive models of ICU mortality using Oxford Acute Severity of Illness Score were developed on admissions during 2007-2009 and validated on admissions during 2010-2011. The most parsimonious Oxford Acute Severity of Illness Score consisted of seven physiologic measurements, elective surgery, age, and prior length of stay. Predictive models of ICU mortality using Oxford Acute Severity of Illness Score achieved an area under the receiver operating characteristic curve of 0.88 and calibrated well. CONCLUSIONS: A reduced severity of illness score had discrimination and calibration equivalent to more complex existing models. This was accomplished in large part using machine-learning algorithms, which can effectively account for the nonlinear associations between physiologic parameters and outcome.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ccm.0b013e31828a24fe

Cites

21 of 21 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 21 references

Cited by

See all 297

Metadata

Authors
Johnson, A. E. W., Kramer, A. A., & Clifford, G. D.
Venue
Critical Care Medicine
Published
2013-07
Volume
41
Issue
7
Pages
1711-1718
ISSN
0090-3493 (ISSN-L)
OpenAlex
W2011861268
Cited by
297
References
21
FWCI
3.46
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A New Severity of Illness Scale Using a Subset of Acute Physiology and Chronic Health Evaluation Data Elements Shows Comparable Predictive Accuracy*. https://app.cochat.ai/papers/10.1097/ccm.0b013e31828a24fe
The paper
Johnson, A. E. W., Kramer, A. A., & Clifford, G. D. (2013). A New Severity of Illness Scale Using a Subset of Acute Physiology and Chronic Health Evaluation Data Elements Shows Comparable Predictive Accuracy*. Critical Care Medicine. https://doi.org/10.1097/ccm.0b013e31828a24fe

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.