Computer versus human diagnosis of melanoma: evaluation of the feasibility of an automated diagnostic system in a prospective clinical trial
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The aim of this study was to evaluate the accuracy of a computer-based system for the automated diagnosis of melanoma in the hands of nonexpert physicians. We performed a prospective comparison between nonexperts using computer assistance and experts without assistance in the setting of a tertiary referral center at a University hospital. Between February and November 2004 we enrolled 511 consecutive patients. Each patient was examined by two nonexpert physicians with low to moderate diagnostic skills who were allowed to use a neural network-based diagnostic system at their own discretion. Every patient was also examined by an expert dermatologist using standard dermatoscopy equipment. The nonexpert physicians used the automatic diagnostic system in 3827 pigmented skin lesions. In their hands, the system achieved a sensitivity of 72% and a specificity of 82%. The sensitivity was significantly lower than that of the expert physician (72 vs. 96%, P = 0.001), whereas the specificity was significantly higher (82 vs. 72%, P<0.01). Three melanomas were missed because the physicians who operated the system did not choose them for examination. The system as a stand-alone device had an average discriminatory power of 0.87, as measured by the area under the receiver operating characteristic curve, with optimal sensitivities and specificities of 75 and 84%, respectively. The diagnostic accuracy achieved in this clinical trial was lower than that achieved in a previous experimental trial of the same system. In total, the performance of a decision-support system for melanoma diagnosis under real-life conditions is lower than that expected from experimental data and depends upon the physicians who are using the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Logistic regression and Artificial Neural Network Classification models: A methodology review
Dreiseitl, S., & Ohno-Machado, L. (2002) · Journal of Biomedical Informatics · doi:10.1016/s1532-0464(03)00034-0 · Cited by 2,177
Self-citationTu, J. V. (1996) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(96)00002-9 · Cited by 1,818 · cited 1×
“Reviews and discussions of these problems in different fields of medicine can be found in the literature [3–9].”
BackgroundDiagnostic accuracy of dermoscopy
Kittler, H., Pehamberger, H., Wolff, K., & Binder, M. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00679-4 · Cited by 1,349
Self-citationDreiseitl, S., & Binder, M. (2005) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2004.07.007 · Cited by 102
Self-citation
Cited by
Tschandl, P., Rosendahl, C., & Kittler, H. (2018) · Scientific Data · doi:10.1038/sdata.2018.161 · Cited by 3,628
Self-citationTschandl, P., Codella, N., Akay, B. N., Argenziano, G., Braun, R. P., Cabo, H., Gutman, D., Halpern, A., Helba, B., Hofmann-Wellenhof, R., et al. (2019) · The Lancet Oncology · doi:10.1016/s1470-2045(19)30333-x · Cited by 555
“8 Although some automated diagnostic devices have been approved by the US Food and Drug Administration, 9,10 such devices are not widely adopted in clinical practice for various reasons—for example, the devices are approved for melanocytic lesions only and they require preselection of lesions by…”
BackgroundSelf-citationComputerized analysis of pigmented skin lesions: A review
Korotkov, K., & Garcia, R. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.08.002 · Cited by 355
Marchetti, M. A., Codella, N. C. F., Dusza, S. W., Gutman, D. A., Helba, B., Kalloo, A., Mishra, N., Carrera, C., Celebi, M. E., DeFazio, J. L., et al. (2018) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2017.08.016 · Cited by 330
Artificial intelligence applications in dermatology: Where do we stand?
Gomolin, A., Netchiporouk, E., Gniadecki, R., & Litvinov, I. V. (2020) · Frontiers in Medicine · doi:10.3389/fmed.2020.00100 · Cited by 142
Metadata
- Authors
- Dreiseitl, S., Binder, M., Hable, K., & Kittler, H.
- Venue
- Melanoma Research
- Published
- 2009-06
- Volume
- 19
- Issue
- 3
- Pages
- 180-184
- ISSN
- 0960-8931 (ISSN-L)
- OpenAlex
- W2033809335
- Cited by
- 72
- References
- 4
- FWCI
- 1.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Computer versus human diagnosis of melanoma: evaluation of the feasibility of an automated diagnostic system in a prospective clinical trial. https://app.cochat.ai/papers/10.1097/cmr.0b013e32832a1e41
- The paper
- Dreiseitl, S., Binder, M., Hable, K., & Kittler, H. (2009). Computer versus human diagnosis of melanoma: evaluation of the feasibility of an automated diagnostic system in a prospective clinical trial. Melanoma Research. https://doi.org/10.1097/cmr.0b013e32832a1e41
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.