The DOI matches its Crossref record.
Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
Abstract
BACKGROUND AND OBJECTIVE: Accurate assessment of a patient's volume status is an important goal for an anaesthetist. However, most variables assessing fluid responsiveness are either invasive or technically challenging. This study was designed to compare the accuracy of arterial pressure-based stroke volume variation (SVV) and variations in the pulse oximeter plethysmographic waveform amplitude as evaluated with the noninvasive calculated pleth variability index (PVI) with central venous pressure to predict the response of stroke volume index (SVI) to volume replacement in patients undergoing major surgery. METHODS: We studied 20 patients scheduled for elective major abdominal surgery. After induction of anaesthesia, all haemodynamic variables were recorded immediately before (T1) and subsequent to volume replacement (T2) by infusion of 6% hydroxy-ethyl starch (HES) 130/0.4 (7 ml kg) at a rate of 1 ml kg min. RESULTS: The volume-induced increase in SVI was at least 15% in 15 patients (responders) and less than 15% in five patients (nonresponders). Baseline SVV correlated significantly with changes in SVI (DeltaSVI; r = 0.80; P < 0.001) as did baseline PVI (r = 0.61; P < 0.004), whereas baseline values of central venous pressure showed no correlation to DeltaSVI. There was no significant difference between the area under the receiver operating characteristic curve for SVV (0.993) and PVI (0.973). The best threshold values to predict fluid responsiveness were more than 11% for SVV and more than 9.5% for PVI. CONCLUSION: Although arterial pressure-derived SVV revealed the best correlation to volume-induced changes in SVI, the results of our study suggest that both variables, SVV and PVI, can serve as valid indicators of fluid responsiveness in mechanically ventilated patients undergoing major surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Marik, P. E., & Cavallazzi, R. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31828a25fd · Cited by 866
Cannesson, M., Le Manach, Y., Hofer, C. K., Goarin, J. P., Lehot, J.-J., Vallet, B., & Tavernier, B. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318225b80a · Cited by 554
Thiele, R. H., Rea, K. M., Turrentine, F. E., Friel, C. M., Hassinger, T. E., Goudreau, B. J., Umapathi, B. A., Kron, I. L., Sawyer, R. G., Hedrick, T. L., et al. (2015) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2014.12.042 · Cited by 446
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Metadata
- Authors
- Zimmermann, M., Feibicke, T., Keyl, C., Prasser, C., Moritz, S., Graf, B. M., & Wiesenack, C.
- Venue
- European Journal of Anaesthesiology
- Published
- 2010-06
- Volume
- 27
- Issue
- 6
- Pages
- 555-561
- ISSN
- 0265-0215 (ISSN-L)
- OpenAlex
- W1996998519
- Cited by
- 167
- References
- 0
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery. https://app.cochat.ai/papers/10.1097/eja.0b013e328335fbd1
- The paper
- Zimmermann, M., Feibicke, T., Keyl, C., Prasser, C., Moritz, S., Graf, B. M., & Wiesenack, C. (2010). Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery. European Journal of Anaesthesiology. https://doi.org/10.1097/eja.0b013e328335fbd1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.