CoChat

An Enzyme-Linked Immunosorbent Assay for Therapeutic Drug Monitoring of Cetuximab

Cézé, Nicolas, Ternant, David, Piller, Friedrich, Degenne, Danielle, Azzopardi, Nicolas, Dorval, Etienne, Watier, Hervé, Lecomte, Thierry, Paintaud, Gilles · 2009 · Therapeutic Drug Monitoring
Cited by 64

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Cetuximab is an anti-epidermal growth factor receptor monoclonal antibody used in the treatment of colorectal and head and neck cancers. Part of the interindividual differences in response may be explained by interindividual variability in pharmacokinetics. An assay measuring cetuximab serum concentrations is therefore needed. An enzyme-linked immunosorbent assay was developed using microtiter plates sensitized with a recombinant human epidermal growth factor receptor extracellular domain. Lower and upper limits of quantitation and limit of detection were determined. Eight standard calibrators (SCs) and 3 quality controls (QCs), that is, 0.75, 7.5, and 15 mg/L, were tested on 5 occasions on 1 day and on 5 occasions on different days. Trough and peak serum concentrations of cetuximab were measured in 15 patients with metastatic colorectal cancer and 1 patient with undetermined neoplasia undergoing cetuximab-based chemotherapy. Cetuximab concentrations were described using a 2-compartment population pharmacokinetic model. Imprecision and accuracy of SC and QC were < or = 20%, except for the 0 and 0.1 mg/L SC concentrations (< or = 20%). The limit of detection was 0.012 mg/L. Lower and upper limits of quantitation were 0.75 and 15 mg/L, respectively. A total number of 198 blood samples were available from the 16 patients. Median (range) trough and peak concentrations during the treatment were 49.6 (5.8-105.4) and 177.2 (97.5-235) mg/L, respectively. This method is rapid, accurate, and reproducible and may be useful for pharmacokinetic and pharmacokinetic-pharmacodynamic studies, as well as in therapeutic drug monitoring of cetuximab.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ftd.0b013e3181b33da3

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

  • Cetuximab Monotherapy and Cetuximab plus Irinotecan in Irinotecan-Refractory Metastatic Colorectal Cancer

    Cunningham, D., Humblet, Y., Siena, S., Khayat, D., Bleiberg, H., Santoro, A., Bets, D., Mueser, M., Harstrick, A., Verslype, C., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa033025 · Cited by 5,035 · cited 1×

    “Initial studies reported relationships both between cetuximab cutaneous toxicity and therapeutic effect and between cetuximab concentrations and cutaneous toxicity.(3,10) More recently, Fracasso et al(11) reported an influence of cetuximab concentrations on both skin toxicity and treatment efficacy.”
    Background

Cited by

See all 64

Metadata

Authors
Cézé, N., Ternant, D., Piller, F., Degenne, D., Azzopardi, N., Dorval, E., Watier, H., Lecomte, T., & Paintaud, G.
Venue
Therapeutic Drug Monitoring
Published
2009-10
Volume
31
Issue
5
Pages
597-601
ISSN
0163-4356 (ISSN-L)
OpenAlex
W2043391903
Cited by
64
References
1
FWCI
1.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.