CoChat

Head-to-head comparison of MASH resolution index versus FAST for noninvasive prediction of resolution of MASH on biopsy

The DOI matches its Crossref record; 43 of the 44 references it cites were found in a registry or an index.

Abstract

Background and Aims: The MASH Resolution Index (MASHResInd) and FibroScan–aspartate aminotransferase (FAST) score have been reported to noninvasively predict the resolution of metabolic dysfunction–associated steatohepatitis (MASH) on histology. This study aimed to examine head-to-head the diagnostic accuracy of the MASHResInd versus FAST score in detecting MASH resolution. Approach and Results: This prospective study included 160 participants (64% female) with biopsy-proven MASH and stage 2 or stage 3 fibrosis from a randomized, multicenter trial of pegozafermin. Participants received either pegozafermin or placebo and underwent contemporaneous liver biopsies, magnetic resonance imaging-proton density fat fraction, and vibration-controlled transient elastography at 2-time points spaced 24 weeks apart. The primary objective was the detection of MASH resolution with no worsening of fibrosis. Diagnostic models were assessed by the area under the receiver operating characteristic curves (AUC) and compared with the Delong test. The median (IQR) age and body mass index of participants were 56.0 (49.0–62.0) years and 36.5 (32.2–40.4) kg/m 2 , respectively. The MASHResInd outperformed FAST for identifying MASH resolution without worsening fibrosis (AUC: 0.83, 95% CI: 0.75–0.91 vs. 0.65, 95% CI: 0.55–0.75, p =0.001). The positive predictive values for MASH resolution were 29% and 26% for the MASHResInd and FAST using rule-in criteria, respectively. The negative predictive values were 100% and 94% for the MASHResInd and FAST using rule-out criteria, respectively. Conclusions: The MASHResInd is better than the FAST score in the noninvasive prediction of MASH resolution. These data may have implications for clinical practice and trials.

Overview

Integrity signals

Registry

Crossref · 10.1097/hep.0000000000001396

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 43 references

Cited by

See all 22

Metadata

Authors
Loomba, R., Daniel, P. C.-Y. N., Amangurbanova, M., Bettencourt, R., Madamba, E., Siddiqi, H., Richards, L., Gottwald, M. D., Feng, S., Margalit, M., & Huang, D. Q.
Affiliations
  • University of California San Diego (US)
  • National University Health System (SG)
  • 89bio (United States) (US)
  • 89bio, Rehovot, Israel
  • National University of Singapore (SG)
Corresponding author
  • Loomba, Rohit
  • Daniel, Peter Chen-Yang Nikhil
  • Huang, Daniel Q.
Venue
Hepatology
Published
2025-05-09
Volume
83
Issue
4
Pages
907-914
ISSN
  • 0270-9139 (ISSN-L)
  • 1527-3350
OpenAlex
W4410344661
Cited by
17
References
44
Citations by year
2026: 12 · 2025: 5
FWCI
11.70
Type
journal article
Language
en
Open access
closed
Locations
  • Hepatology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Hepatology › Liver Disease Diagnosis and Treatment
  • Health Sciences › Medicine › Hepatology › Liver Diseases and Immunity
  • Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes, Cardiovascular Risks, and Lipoproteins
Keywords
nonalcoholic steatohepatitis, FAST score, non-invasive prediction, liver fibrosis, vibration-controlled transient elastography, liver biopsy, diagnostic accuracy
MeSH terms
Aspartate Aminotransferases, Biopsy, Fatty Liver, Female, Humans, Liver, Liver Cirrhosis, Magnetic Resonance Imaging, Male, Middle Aged, Predictive Value of Tests, Prospective Studies, ROC Curve, Elasticity Imaging Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Head-to-head comparison of MASH resolution index versus FAST for noninvasive prediction of resolution of MASH on biopsy. https://app.cochat.ai/papers/10.1097/hep.0000000000001396
The paper
Loomba, R., Daniel, P. C.-Y. N., Amangurbanova, M., Bettencourt, R., Madamba, E., Siddiqi, H., Richards, L., Gottwald, M. D., Feng, S., Margalit, M., & Huang, D. Q. (2026). Head-to-head comparison of MASH resolution index versus FAST for noninvasive prediction of resolution of MASH on biopsy. Hepatology. https://doi.org/10.1097/hep.0000000000001396

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.