Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Although compelling evidence has established the physiological and clinical relevance of aortic SBP (a-SBP), no consensus exists regarding the validity of the available methods/techniques that noninvasively measure it. OBJECTIVES: The systematic review and meta-analysis aimed to determine the accuracy of commercial devices estimating a-SBP noninvasively, which have been validated by invasive measurement of a-SBP. Moreover their optimal mode of application, in terms of calibration, as well as specific technique and arterial site of pulse wave acquisition were further investigated. METHODS: The study was performed according to the PRISMA guidelines; 22 eligible studies were included, which validated invasively 11 different commercial devices in 808 study participants. RESULTS: Overall, the error in a-SBP estimation (estimated minus actual value) was -4.49 mmHg [95% confidence interval (CI): -6.06 to -2.92 mmHg]. The estimated (noninvasive) a-SBP differed from the actual (invasive) value depending on calibration method: by -1.08 mmHg (95% CI: -2.81, 0.65 mmHg) and by -5.81 mmHg (95% CI: -7.79, -3.84 mmHg), when invasively and noninvasively measured brachial BP values were used respectively; by -1.83 mmHg, (95% CI: -3.32, -0.34 mmHg), and by 7.78 mmHg (95% CI: -10.28, -5.28 mmHg), when brachial mean arterial pressure/DBP and SBP/DBP were used, respectively. CONCLUSION: Automated recording of waveforms, calibrated noninvasively by brachial mean arterial pressure/DBP values seems the most promising approach that can provide relatively more accurate, noninvasive estimation of a-SBP. It is still uncertain whether a specific device can be recommended as 'gold standard'; however, a consensus is currently demanding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vlachopoulos, C., Aznaouridis, K., O'Rourke, M. F., Safar, M. E., Baou, K., & Stefanadis, C. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq024 · Cited by 1,363 · cited 1×
“brachial SBP (br-SBP) differs from the corresponding aortic SBP (a-SBP) at the central level of the aorta; the difference (often termed as amplification) of BP between the aorta and the brachial artery does not remain constant but it varies according to physiological [4], pathological, and pharmaceutical mechanisms [5…”
ResultSelf-citation
Cited by
Sharman, J. E., Avolio, A. P., Baulmann, J., Benetos, A., Blacher, J., Blizzard, C. L., Boutouyrie, P., Chen, C.-H., Chowienczyk, P., Cockcroft, J. R., et al. (2017) · European Heart Journal · doi:10.1093/eurheartj/ehw632 · Cited by 231
“Notwithstanding the complex interaction of calibration and wave propagation phenomena relating central and peripheral SBP, it still needs to be determined if the recalibrated brachial SBP derived by this process is an accurate estimate of intra-arterial brachial SBP. Data from meta-analysis indicate that using MAP and…”
MethodSelf-citationPulsatile arterial haemodynamics in heart failure
Weber, T., & Chirinos, J. A. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy346 · Cited by 163
Self-citationGhasemi, Z., Lee, J. C., Kim, C.-S., Cheng, H.-M., Sung, S.-H., Chen, C.-H., Mukkamala, R., & Hahn, J.-O. (2018) · Scientific Reports · doi:10.1038/s41598-018-28604-6 · Cited by 30
Measurements of arterial pressure and flow in vivo
Sharman, J. E., Segers, P., & Chirinos, J. A. (2022) · Textbook of Arterial Stiffness and Pulsatile Hemodynamics in Health and Disease · doi:10.1016/b978-0-323-91391-1.00002-9 · Cited by 3
Self-citation
Metadata
- Authors
- Papaioannou, T. G., Karageorgopoulou, T. D., Sergentanis, T. N., Protogerou, A. D., Psaltopoulou, T., Sharman, J. E., Weber, T., Blacher, J., Daskalopoulou, S. S., Wassertheurer, S., Khir, A. W., Vlachopoulos, C., Stergiopulos, N., Stefanadis, C., Nichols, W. W., & Tousoulis, D.
- Venue
- Journal of Hypertension
- Published
- 2016-07
- Volume
- 34
- Issue
- 7
- Pages
- 1237-1248
- ISSN
- 0263-6352 (ISSN-L)
- OpenAlex
- W2344366440
- Cited by
- 136
- References
- 1
- FWCI
- 3.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies. https://app.cochat.ai/papers/10.1097/hjh.0000000000000921
- The paper
- Papaioannou, T. G., Karageorgopoulou, T. D., Sergentanis, T. N., Protogerou, A. D., Psaltopoulou, T., Sharman, J. E., Weber, T., Blacher, J., Daskalopoulou, S. S., Wassertheurer, S., Khir, A. W., Vlachopoulos, C., Stergiopulos, N., Stefanadis, C., Nichols, W. W., & Tousoulis, D. (2016). Accuracy of commercial devices and methods for noninvasive estimation of aortic systolic blood pressure a systematic review and meta-analysis of invasive validation studies. Journal of Hypertension. https://doi.org/10.1097/hjh.0000000000000921
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.