Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 259

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES: An Experimental and Clinical Study

Eckardt, Claus, Paulo, Erica B. · 2016 · Retina

Abstract

In Brief Purpose: To investigate the feasibility of performing vitrectomies while viewing a three-dimensional image on a large display in a heads-up position. Methods: Twenty volunteers were compared performing meticulous tasks using the heads-up and the traditional method. Some optical parameters, resolution and depth of field, were measured, and the possibilities of digital image processing were investigated. In addition, routine use of the heads-up method for >400 vitrectomies over 8 months was retrospectively analyzed. Results: Of note, 91.7% of the volunteers preferred the ergonomics of the heads-up technique. The two methods were judged to be similar regarding speed and ease of microscopic manipulations and sharpness of image. Significantly fewer mistakes were made with the heads-up method. The measured resolution of the eyepieces was approximately twice that of the three-dimensional display, whereas depth of the field was about equal. Electronic amplification of the camera's signal resulted in increased image brightness, allowing use of reduced endoillumination levels. In clinical routine, better ergonomics, digital image processing, and use of a large display are found to be major advantages. Conclusion: The heads-up method is well suited for vitreoretinal surgery. With further technical improvements, the procedure should soon find widespread use. In heads-up surgery, the surgeon operates while viewing a three-dimensional image on a large high-definition display instead of looking through the oculars of a microscope. Switching from traditional microsurgery to heads-up surgery is quick and unproblematic. It has the major advantages of excellent ergonomics and the ability to apply digital image processing to improve image quality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/iae.0000000000000689

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 259

Metadata

Authors
Eckardt, C., & Paulo, E. B.
Venue
Retina
Published
2016-01
Volume
36
Issue
1
Pages
137-147
ISSN
0275-004X (ISSN-L)
OpenAlex
W2328544209
Cited by
259
References
6
FWCI
12.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES: An Experimental and Clinical Study. https://app.cochat.ai/papers/10.1097/iae.0000000000000689
The paper
Eckardt, C., & Paulo, E. B. (2016). HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES: An Experimental and Clinical Study. Retina. https://doi.org/10.1097/iae.0000000000000689

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.