ULTRA-WIDEFIELD FUNDUS IMAGING: A Review of Clinical Applications and Future Trends
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
In Brief Purpose: To review the basic principles of ultra-widefield fundus imaging and discuss its clinical utility for a variety of retinal and choroidal disorders. Methods: A systematic review of the PubMed database was performed using the search terms Optos, optomap, panoramic, ultra-widefield, wide-angle, and ellipsoid mirror. This yielded 158 publications of which 128 were selected based on content and relevance. Results: A total of 128 articles pertaining to ultra-widefield imaging were cited in this review. Conclusion: Optos ultra-widefield imaging has become an essential tool for the identification of peripheral retinal and vascular pathology. The high resolution and multimodal capabilities of this device are also providing new insights into a variety of disorders, even those that primarily involve the posterior pole. Although the presence of artifact and the need for clinical validation are significant hurdles to more widespread use, ultra-widefield is evolving to become the standard-of-care imaging modality for many diseases and is finding new clinical and research applications such as for screening and telemedicine. This represents a systematic review of the literature pertaining to ultra-widefield imaging and its clinical utility for a variety of retinal and choroidal diseases. An emphasis is placed on the diagnostic power of ultra-widefield imaging compared with that of traditional fundus imaging. Emerging trends and future applications of the technology are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aiello, L. P., Avery, R. L., Arrigg, P. G., Keyt, B. A., Jampel, H. D., Shah, S. T., Pasquale, L. R., Thieme, H., Iwamoto, M. A., Park, J. E., et al. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312203 · Cited by 3,793
ULTRA–WIDE-FIELD ANGIOGRAPHY IMPROVES THE DETECTION AND CLASSIFICATION OF DIABETIC RETINOPATHY
Wessel, M. M., Aaker, G. D., Parlitsis, G., Cho, M., D'Amico, D. J., & Kiss, S. (2012) · Retina · doi:10.1097/iae.0b013e3182278b64 · Cited by 359 · cited 3×
“Ultra-widefield FA has been found to be superior to the seven-standard fields in demonstrating angiographic abnormalities in multiple studies in eyes with diabetic retinopathy.(16,38,39) Wessel et al found that UWF FA showed 3.”
BackgroundResultMidperipheral Fundus Involvement in Diabetic Retinopathy
Shimizu, K., Kobayashi, Y., & Muraoka, K. (1981) · Ophthalmology · doi:10.1016/s0161-6420(81)34983-5 · Cited by 303 · cited 1×
“Peripheral retinal perfusion abnormalities and ischemia have long been identified as major factors in diabetic retinopathy.(26,27) Fluorescein angiography is an essential tool for the management of diabetic retinopathy because it reveals retinal microvascular changes, such as microaneurysms, capillary nonperfusion, br…”
BackgroundSilva, P. S., Cavallerano, J. D., Sun, J. K., Soliman, A. Z., Aiello, L. M., & Aiello, L. P. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.05.004 · Cited by 303
Fundus autofluorescence and age-related macular degeneration
Spaide, R. F. (2003) · Ophthalmology · doi:10.1016/s0161-6420(02)01756-6 · Cited by 255 · cited 1×
“costimulation of collagen autofluorescence.(25) In both cSLO systems, the confocal pinhole greatly decreases out-of-focus autofluorescent signal from the crystalline lens, which can be a major contributor to image degradation commonly encountered in other systems.”
BackgroundVinekar, A., Gilbert, C., Dogra, M., Kurian, M., Shainesh, G., Shetty, B., & Bauer, N. (2014) · Indian Journal of Ophthalmology · doi:10.4103/0301-4738.126178 · Cited by 219
Wessel, M. M., Nair, N., Aaker, G. D., Ehrlich, J. R., D'Amico, D. J., & Kiss, S. (2012) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2011-300774 · Cited by 210 · cited 1×
“One study in treatment-naive patients using UWF FA and OCT reported that retinal nonperfusion was significantly associated with macular edema.(42) Another study measured the “ischemic index” to represent the amount of nonperfusion in a series of patients with recalcitrant diabetic macular edema.”
BackgroundPang, C. E., Shah, V. P., Sarraf, D., & Freund, K. B. (2014) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2014.04.021 · Cited by 208 · cited 2×
“Recent studies using UWF ICGA have demonstrated its diagnostic utility in a variety of disorders, including central serous chorioretinopathy (CSCR), uveitis, and age-related macular degeneration (AMD).(20,21) Despite providing a wide panoramic image of the fundus, the high-density raster scanning of the Optos provides…”
BackgroundMethodPrevalence of diabetic retinopathy within a national diabetic retinopathy screening service
Thomas, R. L., Dunstan, F. D., Luzio, S. D., Chowdhury, S. R., North, R. V., Hale, S. L., Gibbins, R. L., & Owens, D. R. (2015) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-304017 · Cited by 202 · cited 1×
“Diabetes mellitus is an enormous public health issue requiring the screening of many patients for diabetic retinopathy.(118) The use of UWF technology for diabetic screening has many theoretical advantages over traditional fundus photography, including its rapid acquisition time, singlephotograph wide-field capture, a…”
BackgroundDiversity of Retinal Vascular Anomalies in Patients with Familial Exudative Vitreoretinopathy
Kashani, A. H., Brown, K. T., Chang, E., Drenser, K. A., Capone, A., & Trese, M. T. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.05.029 · Cited by 184 · cited 1×
“They also used UWF FA to categorize peripheral angiographic findings into a disease staging system intended to guide management.(89) Optos UWF has also been used to document cases of pediatric retinal detachment.”
MethodQuiram, P. A., Gonzales, C. R., Hu, W., Gupta, A., Yoshizumi, M. O., Kreiger, A. E., & Schwartz, S. D. (2006) · Ophthalmology · doi:10.1016/j.ophtha.2006.05.039 · Cited by 182 · cited 1×
“Ultrawidefield images have also been used to demonstrate pathology and outcomes after inferior retinectomy for recurrent RRD with proliferative vitreoretinopathy.(75) Ultra-widefield pseudocolor images have also been used for the detection of retinal breaks but the sensitivity may be low to replace indirect ophthalmol…”
MethodSelf-citationSchwartz, S. D., Harrison, S. A., Ferrone, P. J., & Trese, M. T. (2000) · Ophthalmology · doi:10.1016/s0161-6420(99)00003-2 · Cited by 178
Self-citationUltra-Wide-Field Fluorescein Angiography of the Ocular Fundus
Manivannan, A., Plskova, J., Farrow, A., Mckay, S., Sharp, P. F., & Forrester, J. V. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.02.055 · Cited by 170 · cited 1×
“Ultra-widefield FA provides high-resolution wide-angle angiographic detail in a single capture using a 488-nm laser with a 500-nm barrier filter.(16,17) This has enabled an unprecedented direct angiographic view of peripheral retinal vascular anatomy, including perfusion abnormalities, structural features, and other a…”
BackgroundRetinal Oxygenation and Laser Treatment in Patients With Diabetic Retinopathy
Stefánsson, E., Machemer, R., de Juan, E., McCuen, B. W., & Peterson, J. (1992) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(14)75750-2 · Cited by 159
Kashani, A. H., Learned, D. L., Nudleman, E., Drenser, K. A., Capone, A., & Trese, M. T. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.08.010 · Cited by 147
SENSITIVITY AND SPECIFICITY OF THE OPTOS OPTOMAP FOR DETECTING PERIPHERAL RETINAL LESIONS
Mackenzie, P. J., Russell, M. K., MA, P. E., Isbister, C., & Maberley, D. (2007) · Retina · doi:10.1097/iae.0b013e3180592b5c · Cited by 120 · cited 1×
“Ultra-widefield pseudocolor images have also been used for the detection of retinal breaks but the sensitivity may be low to replace indirect ophthalmoloscopy.(76,77) Rather, the value of UWF imaging lies in its use as an adjunct to clinical examination to document the retinal detachment and provide functional Fig.”
BackgroundWitmer, M. T., Parlitsis, Patel, & Kiss, S. (2013) · Clinical ophthalmology · doi:10.2147/opth.s41731 · Cited by 117 · cited 1×
“Although the overall coverage of the fundus is less compared with the Optos systems, the Heidelberg module is advantageous in that it provides better superior-inferior coverage, less lash artifact, and more uniform contrast.(9) The imaging of the superior and inferior periphery, however, has recently been improved on…”
BackgroundUltra-wide-field retinal imaging in the management of non-infectious retinal vasculitis
Leder, H. A., Campbell, J. P., Sepah, Y. J., Gan, T. J., Dunn, J. P., Hatef, E., Cho, B., Ibrahim, M., Bittencourt, M. G., Channa, R., et al. (2013) · Journal of Ophthalmic Inflammation and Infection · doi:10.1186/1869-5760-3-30 · Cited by 117 · cited 1×
“In two studies of patients with various underlying diagnoses, the use of UWF FA significantly increased the likelihood of a change in management based on the appearance of disease activity in the periphery.(103,104) Another study of 38 eyes with Behcet retinal vasculitis found that UWF FA detected active vasculitis no…”
BackgroundOwsley, C., McGwin, G., Lee, D. J., Lam, B. L., Friedman, D. S., Gower, E. W., Haller, J. A., Hark, L. A., & Saaddine, J. (2015) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.4652 · Cited by 114 · cited 1×
“Telemedical diagnosis of retinal disease is already widely used and validated in multiple studies for ROP, cytomegalovirus retinitis,(126,127) and diabetic retinopathy.(128) Utilization of the Optos as the retinal imaging device for these indications would carry the same advantages as its use for screening.”
BackgroundKernt, M., Hadi, I., Pinter, F., Seidensticker, F., Hirneiß, C., Haritoglou, C., Kampik, A., ULBIG, M. W., & Neubauer, A. S. (2012) · Diabetes Care · doi:10.2337/dc12-0346 · Cited by 114
Scanning Laser Ophthalmoscopy and Angiography With a Wide-Field Contact Lens System
Staurenghi, G. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.2.244 · Cited by 98 · cited 1×
“These include the Pomerantzeff camera,(2) the Panoret-1000,(3) the RetCam, and various contact and noncontact lens-based systems.(7,8) These instruments can provide 100° to 160° panoramic photographs using either traditional fundus photography or confocal SLO (cSLO).”
BackgroundNeubauer, A. S., Kernt, M., Haritoglou, C., Priglinger, S. G., Kampik, A., & ULBIG, M. W. (2007) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-007-0631-4 · Cited by 96 · cited 1×
“A subsequent study comparing optomap images with the clinical examination found a sensitivity of 94% and a specificity of 100% for diagnosing retinopathy worse than mild nonproliferative diabetic retinopathy.(29) Most studies comparing UWF with traditional photographs have determined the sensitivity and specificity to…”
BackgroundWide-Field Fundus Autofluorescence Imaging of Retinitis Pigmentosa
Oishi, A., Ogino, K., Makiyama, Y., Nakagawa, S., Kurimoto, M., & Yoshimura, N. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.01.050 · Cited by 94
Oliver, S. C. N., & Schwartz, S. D. (2010) · Seminars in Ophthalmology · doi:10.3109/08820538.2010.481239 · Cited by 94 · cited 2×
“Oliver and Schwartz first described the phenomenon of peripheral vascular leakage on UWF FA in eyes with diabetic retinopathy and found that it was present in 41% of eyes.(18) In this case series, peripheral nonperfusion and leakage were associated with neovascularization.”
BackgroundSelf-citationCallaway, N. F., Luo, Z., Henderson, M. T., Wang, S. K., Wallenstein, M. B., Leng, T., & Moshfeghi, D. M. (2014) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/23258160-20140122-01 · Cited by 92
Chan, C. K., Ip, M. S., VanVeldhuisen, P., Oden, N. L., Scott, I. U., Tolentino, M. J., & Blodi, B. A. (2011) · Ophthalmology · doi:10.1016/j.ophtha.2010.11.020 · Cited by 92
Tan, C. S., Heussen, F. M., & Sadda, S. R. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.12.002 · Cited by 92 · cited 1×
“These studies were followed by a large prospective study of 200 eyes with AMD, which beautifully delineated distinct phenotypes of peripheral autofluorescence changes.(22) Importantly, these abnormal FAF patterns were more frequently seen in eyes with neovascular AMD compared with eyes with nonneovascular AMD.”
BackgroundSelf-citationCroft, D. E., Hemert, J. I. V., Wykoff, C. C., Clifton, D. A., Verhoek, M., Fleming, A. D., & Brown, D. M. (2014) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/23258160-20140709-07 · Cited by 92 · cited 1×
“The broad viewing angle that the ellipsoidal mirror provides results in significant warping of the retinal area represented by each pixel depending on its anteriorposterior location.(12) The most peripheral areas can appear magnified up to 2 times the posterior pole, and the horizontal axis seems artifactually stretch…”
BackgroundChiang, M. F., Melia, M., Buffenn, A. N., Lambert, S. R., Recchia, F. M., Simpson, J. L., & Yang, M. B. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2012.01.002 · Cited by 83 · cited 1×
“Screening and fluorescein angiography of retinopathy of prematurity (ROP) have been most commonly performed using the RetCam imaging system.(81) Recent case reports and case series have described success in obtaining clinically useful images in infants with ROP and other proliferative retinopathies using the Optos sys…”
MethodCho, M., & Kiss, S. (2011) · Retina · doi:10.1097/iae.0b013e3181f049ec · Cited by 82
Rasmussen, M. L., Broe, R., Frydkjær-Olsen, U., Olsen, B. S., Mortensen, H. B., Pető, T., & Grauslund, J. (2014) · Journal of Diabetes and its Complications · doi:10.1016/j.jdiacomp.2014.08.009 · Cited by 73
Evaluation and management of pediatric rhegmatogenous retinal detachment
Wenick, A. S., & Barañano, D. E. (2012) · Saudi Journal of Ophthalmology · doi:10.1016/j.sjopt.2012.04.005 · Cited by 62 · cited 1×
“Optos UWF has also been used to document cases of pediatric retinal detachment.(90) Optos has emerged as a practical option for outpatient wide-field imaging in pediatric patients.”
MethodReznicek, L., Klein, T., Wieser, W., Kernt, M., Wolf, A., Haritoglou, C., Kampik, A., Huber, R. A., & Neubauer, A. S. (2014) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-014-2640-4 · Cited by 57 · cited 1×
“The next generation of OCT may use swept-source spectral-domain mode locking lasers capable of a megahertz A-scan rate.(117) These have the potential to provide up to 65° to 70° wide scans of the fundus.”
MethodOishi, M., Oishi, A., Ogino, K., Makiyama, Y., Gotoh, N., Kurimoto, M., & Yoshimura, N. (2014) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.14-13912 · Cited by 56 · cited 1×
“Another study validated the use of UWF imaging on cone and cone–rod dystrophy patients in which the posterior findings tend to predominate.(24) The area of hypoautofluorescence nevertheless correlated well with the size of the scotoma on Goldmann visual field testing and with the severity of electroretinogram dysfunct…”
BackgroundNon-Mydriatic Panoramic Fundus Imaging Using a Non-Contact Scanning Laser-Based System
Friberg, T. R., Pandya, A., & Eller, A. W. (2003) · Ophthalmic surgery, lasers & imaging retina · doi:10.3928/1542-8877-20031101-15 · Cited by 54
Wilson, P. J., Ellis, J. D., MacEwen, C. J., Ellingford, A., Talbot, J. F., & Leese, G. (2010) · Ophthalmologica · doi:10.1159/000284351 · Cited by 51 · cited 1×
“9% for two-field digital photography in identifying diabetic disease warranting referral.(32) In a study of 206 eyes encompassing all levels of diabetic retinopathy, Silva et al(31) found that UWF matched seven-standard film grading of severity in 80% of eyes and was within 1 level in 94.”
BackgroundHeussen, F. M., Tan, C. S., & Sadda, S. R. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.12-9909 · Cited by 48 · cited 1×
“Another retrospective study found that more than 70% of eyes with AMD have peripheral abnormalities detectable on UWF FAF and pseudocolor.(95) These studies were followed by a large prospective study of 200 eyes with AMD, which beautifully delineated distinct phenotypes of peripheral autofluorescence changes.”
BackgroundSelf-citationFEASIBILITY AND CLINICAL UTILITY OF ULTRA-WIDEFIELD INDOCYANINE GREEN ANGIOGRAPHY
Klufas, M. A., Yannuzzi, N. A., Pang, C. E., et al. (2014) · Retina · doi:10.1097/iae.0000000000000318 · Cited by 45
Use of optomap for retinal screening within an eye casualty setting
Khandhadia, S., Madhusudhana, K. C., Kostakou, A., Forrester, J. V., & Newsom, R. (2008) · British Journal of Ophthalmology · doi:10.1136/bjo.2008.148072 · Cited by 45 · cited 1×
“Ultra-widefield pseudocolor images have also been used for the detection of retinal breaks but the sensitivity may be low to replace indirect ophthalmoloscopy.(76,77) Rather, the value of UWF imaging lies in its use as an adjunct to clinical examination to document the retinal detachment and provide functional Fig.”
BackgroundClinical Characteristics of a Large Choroideremia Pedigree Carrying a Novel CHM Mutation
Huang, A. S., Kim, L. A., & Fawzi, A. A. (2012) · Archives of Ophthalmology · doi:10.1001/archophthalmol.2012.1117 · Cited by 38 · cited 1×
“In a large family with choroideremia, UWF FAF detected the remaining islands of intact RPE in affected males and demonstrated a surprisingly high degree of phenotypic variability in carrier females.(97) Importantly, the high resolution of Optos images permitted a careful analysis of both the foveal area and the far pe…”
BackgroundCsutak, A., Lengyel, I., Jónasson, F., Leung, I., Geirsdottir, A., Xing, W., & Pető, T. (2010) · Eye · doi:10.1038/eye.2010.85 · Cited by 37
Peripheral Fundus Autofluorescence Is Increased in Age-Related Macular Degeneration
Reznicek, L., Wasfy, T., Stumpf, C., Kampik, A., ULBIG, M. W., Neubauer, A. S., & Kernt, M. (2012) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.11-8483 · Cited by 36 · cited 1×
“Reznicek et al demonstrated that patients with AMD have significantly increased peripheral autofluorescence and irregularity of that autofluorescence compared with healthy subjects.(94) Another retrospective study found that more than 70% of eyes with AMD have peripheral abnormalities detectable on UWF FAF and pseudoc…”
BackgroundSystematic Analysis of Wide-Field Fundus Autofluorescence (FAF) Imaging in Posterior Uveitis
Reznicek, L., Seidensticker, F., Stumpf, C., Kampik, A., THURAU, S. R., Kernt, M., & Neubauer, A. S. (2013) · Current Eye Research · doi:10.3109/02713683.2013.834938 · Cited by 36 · cited 1×
“Other studies have found that UWF FAF detects a greater extent of retinal involvement in posterior uveitis than UWF pseudocolor images.(23,105,110) The extent of hypoautofluorescent changes seems to correlate with the pattern of visual field defects on Goldmann perimetry.”
BackgroundJirawison, C., Yen, M., Leenasirimakul, P., Chen, J., Guadanant, S., Kunavisarut, P., Patikulsila, D., Watanachai, N., Ausayakhun, S., Heiden, D., et al. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.4766 · Cited by 32
Athikarisamy, S. E., Patole, S., Lam, G. C., Dunstan, C., & Rao, S. C. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2014-304984 · Cited by 27
Liegl, R. G.-H., Liegl, K., Ćeklić, L., Haritoglou, C., Kampik, A., ULBIG, M. W., Kernt, M., & Neubauer, A. S. (2013) · Ophthalmologica · doi:10.1159/000355092 · Cited by 26
Dépistage du décollement de rétine par l’utilisation d’une imagerie panrétinienne
Bonnay, G., Nguyen, F., Meunier, I., Ducasse, A., Hamel, C., & Arndt, C. (2011) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2011.02.012 · Cited by 26 · cited 1×
“A limitation of UWF, however, is that it is less sensitive for detecting lesions in the superior and inferior periphery.(68,69) This can theoretically be overcome by performing steered imaging in the direction of the suspected break (Figure 4).”
BackgroundSalvanos, P., Navaratnam, J., Ma, J., Bragadóttir, R., & Moe, M. C. (2013) · Retina · doi:10.1097/iae.0b013e318283138d · Cited by 23
Clinical images: Peripheral retinal neovascularization in the antiphospholipid antibody syndrome
Lyles, G. W., Moyer, S. S., & Chavala, S. H. (2011) · Arthritis & Rheumatism · doi:10.1002/art.33469 · Cited by 21 · cited 1×
“Ultra-widefield FA has revealed that similar peripheral neovascular changes can also be found in patients with beta-thalassemia(56) and antiphospholipid antibody syndrome.(57) Two cases of Takayasu’s arteritis imaged with UWF FA documented the delayed arm-to-retina circulation, peripheral ischemia, microaneurysm forma…”
BackgroundKernt, M., Pinter, F., Hadi, I., Hirneiß, C., Haritoglou, C., Kampik, A., ULBIG, M. W., & Neubauer, A. S. (2010) · Der Ophthalmologe · doi:10.1007/s00347-010-2226-4 · Cited by 21
Bass, S. J., Sherman, J., & Giovinazzo, V. J. (2010) · Optometry · doi:10.1016/j.optm.2010.07.028 · Cited by 15 · cited 1×
“Bass et al described a case of facioscapulohumeral muscular dystrophy with bilateral capillary dropout, arborization, and telangiectatic microaneurysms.(60) Diffuse retinopathy featuring neovascularization, capillary dropout, and venular aneurysms in a patient with Duchenne muscular dystrophy was imaged with UWF FA, p…”
BackgroundMayer, W. J., Hakim, I., ULBIG, M. W., Kernt, M., & Haritoglou, C. (2012) · Archives of Gynecology and Obstetrics · doi:10.1007/s00404-012-2343-1 · Cited by 5 · cited 1×
“The majority of published cases have used UWF for characterizing rhegmatogenous retinal detachment (RRD), but it has also been used to document serous retinal and choroidal detachments.(66,67) In RRD, the large depth-of-field can capture the causative breaks, the entire clock hour extent of the detached retina, and th…”
Background
Cited by
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Self-citationDigital technology, tele-medicine and artificial intelligence in ophthalmology: A global perspective
Li, J.-P. O., Liu, H., Ting, D. S. J., Jeon, S., Chan, R. V. P., Kim, J. E., Sim, D. A., Thomas, P. B. M., Lin, H., Chen, Y., et al. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100900 · Cited by 626
“With both sensitivities and specificities over 96% in various settings, this system has significant potential to detect more DR patients, given that the retina view scope of UWF images is five times larger than that of tradition fundus images (Nagiel et al., 2016).”
BackgroundPromising Artificial Intelligence-Machine Learning-Deep Learning Algorithms in Ophthalmology
(2019) · Asia-Pacific Journal of Ophthalmology · doi:10.22608/apo.2018479 · Cited by 182
Engelmann, J., McTrusty, A. D., MacCormick, I. J. C., Pead, E., Storkey, A., & Bernabeu, M. O. (2022) · Nature Machine Intelligence · doi:10.1038/s42256-022-00566-5 · Cited by 37
Metadata
- Authors
- Nagiel, A., Lalane, R. A., Sadda, S. R., & Schwartz, S. D.
- Venue
- Retina
- Published
- 2016-04
- Volume
- 36
- Issue
- 4
- Pages
- 660-678
- ISSN
- 0275-004X (ISSN-L)
- OpenAlex
- W2314257879
- Cited by
- 221
- References
- 52
- FWCI
- 17.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.