CoChat

Performance of ChatGPT in Diagnosis of Corneal Eye Diseases

Open access
Delsoz, Mohammad, Madadi, Yeganeh, Raja, Hina, Munir, Wuqaas M., Tamm, Brendan, Mehravaran, Shiva, Soleimani, Mohammad, Djalilian, Ali, Yousefi, Siamak · 2024 · Cornea
Cited by 86

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Purpose: The aim of this study was to assess the capabilities of ChatGPT-4.0 and ChatGPT-3.5 for diagnosing corneal eye diseases based on case reports and compare with human experts. Methods: We randomly selected 20 cases of corneal diseases including corneal infections, dystrophies, and degenerations from a publicly accessible online database from the University of Iowa. We then input the text of each case description into ChatGPT-4.0 and ChatGPT-3.5 and asked for a provisional diagnosis. We finally evaluated the responses based on the correct diagnoses, compared them with the diagnoses made by 3 corneal specialists (human experts), and evaluated interobserver agreements. Results: The provisional diagnosis accuracy based on ChatGPT-4.0 was 85% (17 correct of 20 cases), whereas the accuracy of ChatGPT-3.5 was 60% (12 correct cases of 20). The accuracy of 3 corneal specialists compared with ChatGPT-4.0 and ChatGPT-3.5 was 100% (20 cases, P = 0.23, P = 0.0033), 90% (18 cases, P = 0.99, P = 0.6), and 90% (18 cases, P = 0.99, P = 0.6), respectively. The interobserver agreement between ChatGPT-4.0 and ChatGPT-3.5 was 65% (13 cases), whereas the interobserver agreement between ChatGPT-4.0 and 3 corneal specialists was 85% (17 cases), 80% (16 cases), and 75% (15 cases), respectively. However, the interobserver agreement between ChatGPT-3.5 and each of 3 corneal specialists was 60% (12 cases). Conclusions: The accuracy of ChatGPT-4.0 in diagnosing patients with various corneal conditions was markedly improved than ChatGPT-3.5 and promising for potential clinical integration. A balanced approach that combines artificial intelligence–generated insights with clinical expertise holds a key role for unveiling its full potential in eye care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ico.0000000000003492

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 86

Metadata

Authors
Delsoz, M., Madadi, Y., Raja, H., Munir, W. M., Tamm, B., Mehravaran, S., Soleimani, M., Djalilian, A., & Yousefi, S.
Venue
Cornea
Published
2024-02-23
Volume
43
Issue
5
Pages
664-670
ISSN
0277-3740 (ISSN-L)
OpenAlex
W4392099631
Cited by
86
References
10
FWCI
6.73
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Performance of ChatGPT in Diagnosis of Corneal Eye Diseases. https://app.cochat.ai/papers/10.1097/ico.0000000000003492
The paper
Delsoz, M., Madadi, Y., Raja, H., Munir, W. M., Tamm, B., Mehravaran, S., Soleimani, M., Djalilian, A., & Yousefi, S. (2024). Performance of ChatGPT in Diagnosis of Corneal Eye Diseases. Cornea. https://doi.org/10.1097/ico.0000000000003492

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.