The DOI matches its Crossref record.
Corneal Transplant Rejection Rate and Severity After Endothelial Keratoplasty
Abstract
PURPOSE: To examine the corneal transplant rejection rate and the rate of graft failure subsequent to rejection in the first 2 years after endothelial keratoplasty (EK) and to compare this to background data for similar cases of penetrating keratoplasty (PK). METHODS: Anonymized data from consecutive cases of EK [deep lamellar (DLEK) or Descemet stripping (DSEK)] for Fuchs corneal endothelial dystrophy or pseudophakic bullous keratopathy operated on before August 2004 were collected in 4 participating centers. The number and timing of rejection episodes and cases of subsequent graft failure were recorded, together with the time to cessation of topical steroid medication. Two-year postoperative findings were compared with background data for similar patients undergoing PK recorded in the Swedish Corneal Transplant Registry. RESULTS: Rejection episodes were less frequent after EK than PK (P = 0.035). Fifteen (7.5%) of 199 EK cases had a rejection episode in the first 2 years after surgery versus 92 (13%) of 708 PK cases. Graft failure after rejection in EK may have been less frequent than in PK (P = 0.063), with only 1 (6.7%) case of rejection after EK versus 26 (28.3%) cases of rejection after PK proceeding to graft failure. A strong trend toward continued use of low-dose topical steroid medication was observed in the EK group. Eighty percent of EK patients were still taking topical steroid medication 2 years after surgery, whereas topical steroid medication had been ceased within a year of surgery in almost all PK patients in the comparator group. CONCLUSIONS: Corneal transplant rejection is less frequent and may be less severe after EK than after PK. It is not yet clear whether these apparent differences are simply a product of relatively prolonged postoperative topical steroid cover in EK patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Descemet's Membrane Endothelial Keratoplasty
Price, M. O., Giebel, A. W., Fairchild, K. M., & Price, F. W. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.07.010 · Cited by 654
Self-citationHos, D., Matthaei, M., Bock, F., Maruyama, K., Notara, M., Clahsen, T., Hou, Y., Le, V. N. H., Salabarria, A.-C., Horstmann, J., et al. (2019) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2019.07.001 · Cited by 303
Xu, X., Wu, Y., Gu, R., Zhang, Z., Liu, X., Hu, Y., Li, X., Lin, D., & Bao, Z. (2024) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2024.114351 · Cited by 14
Metadata
- Authors
- Allan, B. D., Terry, M. A., Price, F. W., Price, M. O., Griffin, N. B., & Claesson, M.
- Venue
- Cornea
- Published
- 2007-10
- Volume
- 26
- Issue
- 9
- Pages
- 1039-1042
- ISSN
- 0277-3740 (ISSN-L)
- OpenAlex
- W1990286093
- Cited by
- 212
- References
- 0
- FWCI
- 13.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Corneal Transplant Rejection Rate and Severity After Endothelial Keratoplasty. https://app.cochat.ai/papers/10.1097/ico.0b013e31812f66e5
- The paper
- Allan, B. D., Terry, M. A., Price, F. W., Price, M. O., Griffin, N. B., & Claesson, M. (2007). Corneal Transplant Rejection Rate and Severity After Endothelial Keratoplasty. Cornea. https://doi.org/10.1097/ico.0b013e31812f66e5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.