Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 180

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Repeatability of In Vivo Corneal Confocal Microscopy to Quantify Corneal Nerve Morphology

Open access
Petropoulos, Ioannis N., Manzoor, Tauseef, Morgan, Philip, Fadavi, Hassan, Asghar, Omar, Alam, Uazman, Ponirakis, Georgios, Dabbah, Mohammad A., Chen, Xin, Graham, James, Tavakoli, Mitra, Malik, Rayaz A. · 2013 · Cornea

Abstract

PURPOSE: To establish intraobserver and interobserver repeatability, agreement, and symmetry of corneal nerve fiber (NF) morphology in healthy subjects using in vivo corneal confocal microscopy. METHODS: Nineteen subjects underwent in vivo corneal confocal microscopy (Heidelberg Retinal Tomograph III Rostock Cornea Module) at baseline and 7 days apart. Bland-Altman plots were generated to assess agreement, and the intraclass correlation coefficient and coefficient of repeatability were calculated to estimate intraobserver and interobserver repeatability for corneal NF density (numbers per square millimeter), nerve branch density (NBD; numbers per square millimeter), NF length (millimeters per square millimeter), and NF tortuosity coefficient. Symmetry between the right and left eyes was also assessed. RESULTS: Intraclass correlation coefficient and coefficient of repeatability for intraobserver repeatability were 0.66 to 0.74 and 0.17 to 0.64, for interobserver repeatability 0.54 to 0.93 and 0.15 to 0.85, and for symmetry 0.34 to 0.77 and 0.17 to 0.63, respectively. NBD demonstrated low repeatability. CONCLUSIONS: This study demonstrates good repeatability for the manual assessment of all major corneal NF parameters with the exception of NBD, which highlights the difficulty in defining nerve branches and suggests the need for experienced observers or automated image analysis to ensure optimal repeatability.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/ico.0b013e3182749419

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 180

Metadata

Authors
Petropoulos, I. N., Manzoor, T., Morgan, P., Fadavi, H., Asghar, O., Alam, U., Ponirakis, G., Dabbah, M. A., Chen, X., Graham, J., Tavakoli, M., & Malik, R. A.
Venue
Cornea
Published
2013-05
Volume
32
Issue
5
Pages
e83-e89
ISSN
0277-3740 (ISSN-L)
OpenAlex
W2147926338
Cited by
180
References
2
FWCI
7.81
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Repeatability of In Vivo Corneal Confocal Microscopy to Quantify Corneal Nerve Morphology. https://app.cochat.ai/papers/10.1097/ico.0b013e3182749419
The paper
Petropoulos, I. N., Manzoor, T., Morgan, P., Fadavi, H., Asghar, O., Alam, U., Ponirakis, G., Dabbah, M. A., Chen, X., Graham, J., Tavakoli, M., & Malik, R. A. (2013). Repeatability of In Vivo Corneal Confocal Microscopy to Quantify Corneal Nerve Morphology. Cornea. https://doi.org/10.1097/ico.0b013e3182749419

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.