Initial Clinical Experience With the CyPass Micro-Stent: Safety and Surgical Outcomes of a Novel Supraciliary Microstent
The DOI matches its Crossref record.
Abstract
PURPOSE: To evaluate safety and clinical outcomes of a novel supraciliary device, the CyPass Micro-Stent, for surgical treatment of open-angle glaucoma when implanted in conjunction with cataract surgery. PATIENTS AND METHODS: Subjects (n=142) with open-angle glaucoma and cataract underwent combined phacoemulsification, with intraocular lens insertion, and microstent implantation into the supraciliary space of study eyes (n=167). Two analysis cohorts were prespecified based upon medicated baseline intraocular pressure (IOP): ≥21 mm Hg (cohort 1, n=65) or <21 mm Hg (cohort 2, n=102). Glaucoma medications were discontinued or tapered at surgery, and restarted at investigator discretion. The main postoperative outcome measures were adverse events, IOP changes, and number of IOP-lowering medications. RESULTS: Mean±SD follow-up was 294±121 days. No major intraoperative or postoperative complications occurred. Preoperative baseline mean IOP was 20.2±6.0 mm Hg and mean number of IOP-lowering medications was 2.0±1.1. Cohort 1 showed a 35% decrease in mean IOP and a 49% reduction in mean glaucoma medication usage; cohort 2 demonstrated a 75% reduction in mean medication usage while maintaining mean IOP<21 mm Hg. For all eyes, mean IOP at 12 months was 15.9±3.1 mm Hg (14% reduction from baseline). Early and late postoperative IOP elevation occurred in 1.2% and 1.8% of eyes, respectively. Two subjects developed mild transient hyphema, and none exhibited prolonged inflammation, persistent hypotony, or hypotony maculopathy. CONCLUSIONS: CyPass Micro-Stent implantation, combined with cataract surgery, resulted in minimal complications and reduced IOP and IOP-lowering medication use at 12 months postoperatively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Glaucoma treatment trends: a review
Conlon, R., Saheb, H., & Ahmed, I. I. K. (2017) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2016.07.013 · Cited by 344
Self-citationVold, S., Ahmed, I. I. K., Craven, E. R., Mattox, C., Stamper, R., Packer, M., Brown, R. H., & Ianchulev, T. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.06.032 · Cited by 274
Self-citationThe suprachoroidal space: from potential space to a space with potential
Moisseiev, E., Loewenstein, A., & Yiu, G. (2016) · Clinical Ophthalmology · doi:10.2147/opth.s89784 · Cited by 76
Drug delivery via the suprachoroidal space for the treatment of retinal diseases
Naftali Ben Haim, L., & Moisseiev, E. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13070967 · Cited by 68
Endovascular Microrobotics for Neurointervention
Santiago-Dieppa, D. R., & Friend, J. (2024) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060523-010720 · Cited by 12
Metadata
- Authors
- Hoeh, H., Vold, S. D., Ahmed, I. K., Anton, A., Rau, M., Singh, K., Chang, D. F., Shingleton, B. J., & Ianchulev, T.
- Venue
- Journal of Glaucoma
- Published
- 2016-01
- Volume
- 25
- Issue
- 1
- Pages
- 106-112
- ISSN
- 1057-0829 (ISSN-L)
- OpenAlex
- W2320240353
- Cited by
- 92
- References
- 0
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial Clinical Experience With the CyPass Micro-Stent: Safety and Surgical Outcomes of a Novel Supraciliary Microstent. https://app.cochat.ai/papers/10.1097/ijg.0000000000000134
- The paper
- Hoeh, H., Vold, S. D., Ahmed, I. K., Anton, A., Rau, M., Singh, K., Chang, D. F., Shingleton, B. J., & Ianchulev, T. (2016). Initial Clinical Experience With the CyPass Micro-Stent: Safety and Surgical Outcomes of a Novel Supraciliary Microstent. Journal of Glaucoma. https://doi.org/10.1097/ijg.0000000000000134
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.