Survey of cataract surgeons' and nurses' attitudes toward operating room waste
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
In an online survey of more than 1300 cataract surgeons and nurses, 93% believed that operating room waste is excessive and should be reduced; 78% believed that we should reuse more supplies; 90% were concerned about global warming; and 87% wanted medical societies to advocate for reducing the surgical carbon footprint. The most commonly cited reasons for excessive waste were regulatory and manufacturer restrictions on reuse or multiple use of devices, supplies, and pharmaceuticals. More than 90% believed that profit, liability reduction, and failure to consider carbon footprint drive manufacturers to produce more single-use products; more than 90% want more reusable products and more regulatory and manufacturer discretion over when and which products can be reused. Assuming comparable cost, 79% of surgeons preferred reusable over disposable instruments. In order of decreasing consensus, most were interested in reusing topical and intracameral medications, phacoemulsification tips, irrigating solutions/tubing, blades, cannulas, devices, and surgical gowns.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A prepandemic survey of ophthalmic surgeons and nurses showed overwhelming support for sustainability interventions such as the reuse of supplies and multi-dosing of medications, 45”
From How Ophthalmologists Can Decarbonize Eye Care (2023) · cites this paper as [45]
Citations
Cites
Thiel, C. L., Schehlein, E., Ravilla, T., Ravindran, R. D., Robin, A. L., Saeedi, O. J., Schuman, J. S., & Venkatesh, R. (2017) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2017.08.017 · Cited by 265 · cited 8×
“more than 1 patient) 8 (6) 70 (44) 15 (45) 6 (4)”
BackgroundSelf-citationEstimated Global Disease Burden From US Health Care Sector Greenhouse Gas Emissions
Eckelman, M. J., & Sherman, J. D. (2018) · American Journal of Public Health · doi:10.2105/ajph.2017.303846 · Cited by 258 · cited 4×
“Decreased efficiency 7 (17) 31 (44) 62 (39) Malpractice liability 51 (46) 38 (42) 11 (11)”
BackgroundInfluentialThe carbon footprint of cataract surgery
Morris, D. S., Wright, T., Somner, J. E. A., & Connor, A. (2013) · Eye · doi:10.1038/eye.2013.9 · Cited by 238 · cited 6×
“Capsulotomy needle/cystotome 13 (10) 59 (41) 22 (42) 6 (7) Small-gauge cannulas 27 (26) 47 (34) 21 (36) 6 (4)”
BackgroundInfluentialChang, D. F., Braga-Mele, R., Henderson, B. A., Mamalis, N., & Vasavada, A. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2015.01.014 · Cited by 179
Self-citationEndophthalmitis Reduction with Intracameral Moxifloxacin Prophylaxis
Haripriya, A., Chang, D. F., & Ravindran, R. D. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.01.026 · Cited by 179 · cited 5×
“Perceived safety benefits of disposable items 74 (73) 22 (23) 4 (4) Perceived performance benefits of disposable items 33 (49) 44 (40) 24 (10)”
BackgroundSelf-citationEndophthalmitis after Cataract Surgery in the United States
Pershing, S., Lum, F., Hsu, S., Kelly, S., Chiang, M. F., Rich, W. L., & Parke, D. W. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2019.08.026 · Cited by 171 · cited 9×
“Save and donate unused surgical supplies 26 (32) 71 (64) 2 (2) 1 (2)”
BackgroundInfluentialUnger, S., & Landis, A. (2016) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2015.07.144 · Cited by 134 · cited 1×
“Metal blades 14 (21) 64 (48) 18 (27) 4 (4) Nonmetal surgical devices (iris and capsule retractors, pupil expansion rings) 9 (13) 63 (38) 20 (40) 8 (9)”
Haripriya, A., Chang, D. F., & Ravindran, R. D. (2019) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2019.04.018 · Cited by 126 · cited 2×
“Do not change surgical gowns between every case (surgeon and scrub nurse) 4 (1) 60 (21) 28 (70) 7 (8)”
BackgroundSelf-citationTauber, J., Chinwuba, I., Kleyn, D., Rothschild, M., Kahn, J., & Thiel, C. L. (2019) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2019.2901 · Cited by 83 · cited 4×
“Surgeon preference for single-use items 26 (44) 45 (41) 28 (15) Surgeons do not reuse supplies when possible 33 (39) 37 (41) 30 (20) Surgical teams open too many supplies during surgery 37 (31) 39 (43) 24 (26) Single-use items packaged in ways that create unnecessary waste 71 (71) 24 (23) 5 (6)”
BackgroundSelf-citationGuidelines for the cleaning and sterilization of intraocular surgical instruments
Chang, D. F., & Mamalis, N. (2018) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2018.05.001 · Cited by 77 · cited 5×
“Lidocaine 30 (36) 65 (55) 3 (7) 2 (2) Capsular dye 10 (11) 80 (62) 7 (20) 3 (7) Corticosteroids (eg, triamcinolone) 16 (22) 76 (59) 4 (12) 4 (7) Commercially packaged solutions (in general) 11 (12) 84 (67) 3 (12) 2 (9)”
Self-citation
Cited by
Cicinelli, M. V., Buchan, J. C., Nicholson, M., Varadaraj, V., & Khanna, R. C. (2023) · The Lancet · doi:10.1016/s0140-6736(22)01839-6 · Cited by 332
Chen, S. P., Woreta, F. A., & Chang, D. F. (2025) · JAMA · doi:10.1001/jama.2025.1597 · Cited by 118
Self-citationSustainability Initiatives in the Operating Room
Wu, S., & Cerceo, E. A. (2021) · The Joint Commission Journal on Quality and Patient Safety · doi:10.1016/j.jcjq.2021.06.010 · Cited by 107
Addressing the environmental sustainability of eye health-care delivery: a scoping review
Buchan, J. C., Thiel, C. L., Steyn, A., Somner, J., Venkatesh, R., Burton, M. J., & Ramke, J. (2022) · The Lancet Planetary Health · doi:10.1016/s2542-5196(22)00074-2 · Cited by 68
Self-citationBolten, A., Kringos, D. S., Spijkerman, I. J. B., & Weiland, N. H. S. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.07.011 · Cited by 71
Metadata
- Authors
- Chang, D. F., Thiel, C. L., & for the Ophthalmic Instrument Cleaning and Sterilization Task Force
- Affiliations
- University of California, San Francisco (US)
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2020-07
- Volume
- 46
- Issue
- 7
- Pages
- 933-940
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- 1873-4502
- OpenAlex
- W3043198564
- Cited by
- 95
- References
- 14
- Citations by year
- 2026: 14 · 2025: 21 · 2024: 15 · 2023: 19 · 2022: 19 · 2021: 4 · 2020: 3
- FWCI
- 8.44
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Cataract & Refractive Surgery (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare and Environmental Waste Management
- Life Sciences › Immunology and Microbiology › Microbiology › Medical Device Sterilization and Disinfection
- Health Sciences › Health Professions › General Health Professions › Healthcare cost, quality, practices
- Keywords
- operating room waste, cataract surgery, single-use products, environmental attitudes, surgeon attitudes, nurses' attitudes, irrigating solutions, surgical gowns
- MeSH terms
- Attitude, Cataract, Disposable Equipment, Humans, Nurses, Operating Rooms, Equipment Reuse, Surgeons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Survey of cataract surgeons' and nurses' attitudes toward operating room waste. https://app.cochat.ai/papers/10.1097/j.jcrs.0000000000000267
- The paper
- Chang, D. F., Thiel, C. L., & for the Ophthalmic Instrument Cleaning and Sterilization Task Force. (2020). Survey of cataract surgeons' and nurses' attitudes toward operating room waste. Journal of Cataract and Refractive Surgery. https://doi.org/10.1097/j.jcrs.0000000000000267
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.