Feasibility and Variability of Automated Pupillometry Among Stroke Patients and Healthy Participants: Potential Implications for Clinical Practice
The DOI matches its Crossref record.
Abstract
Background: Early neurological deterioration (END) is common after stroke and represents a poor prognostic marker. Manual pupillary assessment to detect END is subjective and has poor interrater reliability. Novel methods of automated pupillometry may be more reliable and accurate. This study aims to evaluate the acceptability and feasibility of automated pupillometry in patients with acute stroke and healthy volunteers and compare its interrater reliability with that of the traditional manual method. Methods: Automated and manual pupillary assessments were recorded between 2 independent observers alongside routine neurological observations from 12 acute stroke patients at a high risk of END. The proportion of completed measurements, adverse events, and qualitative feedback from patients and staff nurses was used to assess acceptability and feasibility of automated pupillometry. Paired automated and manual assessments were supplemented with measures from healthy volunteers to analyze measures of variability and agreement. Results: Automated pupillometry was acceptable and safe among 12 acute stroke patients, but feasibility criteria were not attained. Interrater agreement for automated pupillometry was superior to manual assessment for measurements of pupil size, anisocoria, and pupillary light reactivity, for both patients and healthy volunteers. Substantial disparity existed in agreement between automated and manual assessments of these parameters. Conclusions: Automated pupillometry represents an alternative to manual pupillary assessment that may have greater interrater agreement and reliability. As an optimized method of neurological assessment, it has the potential to improve detection and treatment of conditions leading to END after stroke.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent studies have demonstrated that parameters obtained through automated infrared pupillometry exhibit greater reliability compared to manual measurements and particularly support clinical decisionmaking processes in intensive care units (17,18).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [17]
In the citing paper
“In addition, pupil constriction and dilation velocities have been reported to provide supplementary information regarding sedation level, nociceptive responses, and autonomic function (17,37).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [17]
In the citing paper
“The advancement of automated pupillometry devices has increased the reliability of measurements and has made them an integral part of standardized neurological monitoring, particularly in intensive care settings (17,18).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [17]
In the citing paper
“The advancement of automated pupillometry devices has increased the reliability of measurements and has made them an integral part of standardized neurological monitoring, particularly in intensive care settings (17,18).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [17]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 14
- 2008, Acute stroke unit care and early neurological deterioration in ischemic stroke, J Neurol, 255, 1012, 10.1007/s00415-008-0820-z · DOI
- 2006, Early neurological deterioration in acute stroke: clinical characteristics and impact on outcome, Q J Med, 99, 625, 10.1093/qjmed/hcl082 · DOI
- 2005, Neurologic worsening during the acute phase of ischemic stroke, Arch Neurol, 62, 393, 10.1001/archneur.62.3.393 · DOI · Paper page
- 2016, Interrater reliability of pupillary assessments, Neurocrit Care, 24, 251, 10.1007/s12028-015-0182-1 · DOI
- 2016, Reliability of standard pupillometry practice in neurocritical care: an observational, double-blinded study, Crit Care, 20, 99, 10.1186/s13054-016-1239-z · DOI · Paper page
- 2017, High variance in pupillary examination findings among postanesthesia care unit nurses, J Perianesth Nurs, 32, 219, 10.1016/j.jopan.2015.05.117 · DOI · Paper page
- 2008, Early neurological deterioration in acute ischaemic stroke: predictors, mechanisms and management, Postgrad Med J, 84, 412, 10.1136/pgmj.2007.066118 · DOI · Paper page
- 1999, Progression in acute stroke: value of the initial NIH stroke scale score on patient stratification in future trials, Stroke, 30, 1208, 10.1161/01.STR.30.6.1208 · DOI · Paper page
- 2018, Understanding the relationship between the Neurologic Pupil index and constriction velocity values, Sci Rep, 8, 6992, 10.1038/s41598-018-25477-7 · DOI
- 2016, The use of automated pupillometry in critical care, Crit Care Nurs Clin North Am, 28, 101, 10.1016/j.cnc.2015.09.003 · DOI
- 2005, Pupil examination: validity and clinical utility of an automated pupillometer, J Neurosci Nurs, 37, 34, 10.1097/01376517-200502000-00006 · doi:10.1097/01376517-200502000-00006
- 2017, Correlations between hourly pupillometer readings and intracranial pressure values, J Neurosci Nurs, 49, 229, 10.1097/JNN.0000000000000290 · doi:10.1097/jnn.0000000000000290
- 2011, Pupillary reactivity as an early indicator of increased intracranial pressure: the introduction of the neurological pupil index, Surg Neurol Int, 2, 82, 10.4103/2152-7806.82248 · DOI · Paper page
- 2016, Inter-device reliability of the NPi-100 pupillometer, J Clin Neurosci, 33, 79, 10.1016/j.jocn.2016.01.039 · doi:10.1016/j.jocn.2016.01.039
Cited by
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Metadata
- Authors
- Marshall, M., Deo, R., Childs, C., & Ali, A.
- Venue
- Journal of Neuroscience Nursing
- Published
- 2019-04
- Volume
- 51
- Issue
- 2
- Pages
- 84-88
- ISSN
- 1945-2810
- 0888-0395
- Cited by
- 18
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility and Variability of Automated Pupillometry Among Stroke Patients and Healthy Participants: Potential Implications for Clinical Practice. https://app.cochat.ai/papers/10.1097/jnn.0000000000000416
- The paper
- Marshall, M., Deo, R., Childs, C., & Ali, A. (2019). Feasibility and Variability of Automated Pupillometry Among Stroke Patients and Healthy Participants: Potential Implications for Clinical Practice. Journal of Neuroscience Nursing. https://doi.org/10.1097/jnn.0000000000000416
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.