Neurological Pupil Index as an Indicator of Irreversible Cerebral Edema: A Case Series
The DOI matches its Crossref record.
Abstract
BACKGROUND: Assessing the pupillary light reflex is a core component of neurological assessments. Pupil size and reactivity can provide early warning about early neurological decline. Automated infrared pupillometry is noninvasive and easy to use and has greater reliability compared with manual assessments to obtain objective and consistent measurements of pupillary size and reactivity to light. METHODS: This is a case series of 3 patients who had poor baseline clinical neurological examinations. Because it would be more difficult to detect acute neurological deterioration, automated infrared pupillometry and the Neurological Pupil index (NPi) were used in addition to the clinical neurological examination. NPi values < 3.0 prompted further imaging. RESULTS: In each case, abnormal NPi values prompted emergent imaging that confirmed acute cerebral edema and resulted in a change in management and treatment plan. CONCLUSION: The automated infrared pupillometry is a noninvasive monitor that can provide additional objective data in patients with a poor baseline neurological examination in whom it may otherwise be difficult to detect neurological deterioration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Notably, decreases in Neurological Pupil Index (NPi) values have been reported as potential early indicators of clinical deterioration (9).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [9]
In the citing paper
“Furthermore, sudden changes in NPi values have been reported as early indicators of increased intracranial pressure and a potential risk of herniation (9,19).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [9]
In the citing paper
“Recent studies have demonstrated that quantitative pupillometry serves not only as a tool for assessing current neurological status but also as a strong biomarker for elevated intracranial pressure, risk of herniation, and neuroprognostication following cardiac arrest (9,19).”
From Pupil and Pupillary Light Reflex (2025) · cites this paper as [9]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 10
- 2014, Automated pupillometer for monitoring the critically ill patient: a critical appraisal, J Crit Care, 29, 599, 10.1016/j.jcrc.2014.01.012 · DOI
- 2019, Objective pupillometry as an adjunct to prediction and assessment for oculomotor nerve injury and recovery: potential for practical applications, World Neurosurg, 121, e475, 10.1016/j.wneu.2018.09.140 · DOI
- 2016, Underestimation of pupil size by critical care and neurosurgical nurses, Am J Crit Care, 25, 213, 10.4037/ajcc2016554 · DOI · Paper page
- 2003, Use of admission Glasgow Coma Score, pupil size, and pupil reactivity to determine outcome for trauma patients, J Trauma, 55, 437, 10.1097/01.TA.0000081882.79587.17 · doi:10.1097/01.ta.0000081882.79587.17
- 2016, Inter-device reliability of the NPi-100 pupillometer, J Clin Neurosci, 33, 79, 10.1016/j.jocn.2016.01.039 · doi:10.1016/j.jocn.2016.01.039
- 2009, Clinical utility of an automated pupillometer for assessing and monitoring recipients of liver transplantation, Liver Transpl, 15, 1718, 10.1002/lt.21924 · doi:10.1002/lt.21924
- 2019, Distributions and reference ranges for automated pupillometer values in neurocritical care patients, J Neurosci Nurs, 51, 335, 10.1097/JNN.0000000000000478 · doi:10.1097/jnn.0000000000000478
- 2017, Establishing normative data for pupillometer assessment in neuroscience intensive care: the "END-PANIC" registry, J Neurosci Nurs, 49, 251, 10.1097/JNN.0000000000000296 · doi:10.1097/jnn.0000000000000296
- 2018, Automated pupillometry and detection of clinical transtentorial brain herniation: a case series, Mil Med, 183, e113
- 2019, Effects of osmotic therapy on pupil reactivity: quantification using pupillometry in critically ill neurologic patients, Neurocrit Care, 30, 307, 10.1007/s12028-018-0620-y · DOI
Cited by
Pupil and Pupillary Light Reflex
Özdağ, D., & Oztas, B. (2025) · Sakarya Üniversitesi Holistik Sağlık Dergisi · doi:10.54803/sauhsd.1767753 · Cited by 1
Metadata
- Authors
- Cortes, M. X., Siaron, K. B., Nadim, H. T., Ahmed, K. M., & Romito, J. W.
- Venue
- Journal of Neuroscience Nursing
- Published
- 2021-06
- Volume
- 53
- Issue
- 3
- Pages
- 145-148
- ISSN
- 1945-2810
- 0888-0395
- Cited by
- 21
- References
- 0
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neurological Pupil Index as an Indicator of Irreversible Cerebral Edema: A Case Series. https://app.cochat.ai/papers/10.1097/jnn.0000000000000584
- The paper
- Cortes, M. X., Siaron, K. B., Nadim, H. T., Ahmed, K. M., & Romito, J. W. (2021). Neurological Pupil Index as an Indicator of Irreversible Cerebral Edema: A Case Series. Journal of Neuroscience Nursing. https://doi.org/10.1097/jnn.0000000000000584
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.