Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 166

The DOI matches its Crossref record.

The Reliability of the Modified Balance Error Scoring System

Hunt, Tamerah N, Ferrara, Michael S, Bornstein, Robert A, Baumgartner, Ted A·2009·Clinical Journal of Sport Medicine

Abstract

OBJECTIVE: Study 1 investigated the intraclass reliability and percent variance associated with each component within the traditional Balance Error Scoring System (BESS) protocol. Study 2 investigated the reliability of subsequent modifications of the BESS. DESIGN: Prospective cross-sectional examination of the traditional and modified BESS protocols. SETTING: Schools participating in Georgia High School Athletics Association. INTERVENTION: The modified BESS consisted of 2 surfaces (firm and foam) and 2 stances (single-leg and tandem-leg stance) repeated for a total of three 20-second trials. PARTICIPANTS: Participants consisted of 2 independent samples of high school athletes aged 13 to 19 years. MAIN OUTCOME MEASURES: Percent variance for each condition of the BESS was obtained using GENOVA 3.1. An intraclass reliability coefficient and repeated measures analysis of variance were calculated using SPSS 13.0. RESULTS: Study 1 obtained an intraclass correlation coefficient (r = 0.60) with stance accounting for 55% of the total variance. Removing the double-leg stance increased the intraclass correlation coefficient (r = 0.71). Study 2 found a statistically significant difference between trials 1 and 2 (F(1.65,286) = 4.890, P = 0.013) and intraclass reliability coefficient of r = 0.88 for 3 trials of 4 conditions. CONCLUSIONS: The variance associated with the double-leg stance was very small, and when removed, the intraclass reliability coefficient of the BESS increased. Removal of the double-leg stance and addition of 3 trials of 4 conditions provided an easily administered, cost-effective, time-efficient tool that provides reliable objective information for clinicians to base clinical decisions upon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/jsm.0b013e3181c12c7b

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 166

Metadata

Authors
Hunt, T. N., Ferrara, M. S., Bornstein, R. A., & Baumgartner, T. A.
Venue
Clinical Journal of Sport Medicine
Published
2009-11
Volume
19
Issue
6
Pages
471-475
ISSN
1050-642X (ISSN-L)
OpenAlex
W2149684184
Cited by
166
References
0
FWCI
13.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Reliability of the Modified Balance Error Scoring System. https://app.cochat.ai/papers/10.1097/jsm.0b013e3181c12c7b
The paper
Hunt, T. N., Ferrara, M. S., Bornstein, R. A., & Baumgartner, T. A. (2009). The Reliability of the Modified Balance Error Scoring System. Clinical Journal of Sport Medicine. https://doi.org/10.1097/jsm.0b013e3181c12c7b

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.