Correlation between the Size of the Solid Component on Thin-Section CT and the Invasive Component on Pathology in Small Lung Adenocarcinomas Manifesting as Ground-Glass Nodules
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Travis, W. D., Brambilla, E., Noguchi, M., Nicholson, A. G., Geisinger, K. R., Yatabe, Y., Beer, D. G., Powell, C. A., Riely, G. J., Van Schil, P. E., et al. (2011) · Journal of Thoracic Oncology · doi:10.1097/jto.0b013e318206a221 · Cited by 4,792 · cited 3×
“The final pathologic diagnoses were determined postoperatively by a retrospective pathologic review of all specimens by the two pathologists, according to the new adenocarcinoma classification.(1)”
BackgroundMethodInfluentialNaidich, D. P., Bankier, A. A., MacMahon, H., Schaefer-Prokop, C. M., Pistolesi, M., Goo, J. M., Macchiarini, P., Crapo, J. D., Herold, C. J., Austin, J. H., et al. (2013) · Radiology · doi:10.1148/radiol.12120628 · Cited by 1,000
Self-citationAoki, T., Tomoda, Y., Watanabe, H., Nakata, H., Kasai, T., Hashimoto, H., Kodate, M., Osaki, T., & Yasumoto, K. (2001) · Radiology · doi:10.1148/radiol.2203001701 · Cited by 364
Suzuki, K., Kusumoto, M., Watanabe, S.-I., Tsuchiya, R., & Asamura, H. (2006) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2005.07.058 · Cited by 323
Lee, S. M., Park, C. M., Goo, J. M., Lee, H.-J., Wi, J. Y., & Kang, C. H. (2013) · Radiology · doi:10.1148/radiol.13120949 · Cited by 299 · cited 2×
“In pure GGNs, 8 mm and 10 mm have been suggested as thresholds that showed high specificity in differentiating premalignant lesions from malignant lesions and preinvasive lesions from invasive adenocarcinomas, respectively.(30,31) However, CT findings or measurement thresholds for MIAs have not been reported.”
BackgroundResultSelf-citationMazaheri, Y., Hricak, H., Fine, S. W., Akin, O., Shukla-Dave, A., Ishill, N. M., Moskowitz, C. S., Grater, J. E., Reuter, V. E., Zakian, K. L., et al. (2009) · Radiology · doi:10.1148/radiol.2523081423 · Cited by 205
Lobectomy Versus Sublobar Resection for Small (2 cm or Less) Non–Small Cell Lung Cancers
Wolf, A. S., Richards, W. G., Jaklitsch, M. T., Gill, R., Chirieac, L. R., Colson, Y. L., Mohiuddin, K., Mentzer, S. J., Bueno, R., Sugarbaker, D. J., et al. (2011) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2011.06.099 · Cited by 178
Surgical implications of the new IASLC/ATS/ERS adenocarcinoma classification
Van Schil, P. E., Asamura, H., Rusch, V. W., Mitsudomi, T., Tsuboi, M., Brambilla, E., & Travis, W. D. (2012) · European Respiratory Journal · doi:10.1183/09031936.00027511 · Cited by 170
Feasibility of Pathology-Correlated Lung Imaging for Accurate Target Definition of Lung Tumors
Stroom, J. C., Blaauwgeers, H., van Baardwijk, A. A. W., Boersma, L. J., Lebesque, J. V., Theuws, J. C. M., van Suylen, R. J., Klomp, H. M., Liesker, K. R., van Pel, R., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.04.065 · Cited by 97 · cited 1×
“Our data are consistent with previous reports in that CT measurements tended to overestimate the true pathologic size of the tumors with a significant difference.(37,38) Furthermore, in this study, 3D solid CT measurements also showed a tendency to overestimate the invasive component, whereas 2D solid CT measurements…”
ResultPrognostic Significance of Thin-Section CT Scan Findings in Small-Sized Lung Adenocarcinoma
Hashizume, T., Yamada, K., Okamoto, N., Saito, H., Oshita, F., Kato, Y., Ito, H., Nakayama, H., Kameda, Y., & Noda, K. (2007) · CHEST Journal · doi:10.1378/chest.07-1533 · Cited by 73
Lampen-Sachar, K., Zhao, B., Zheng, J., Moskowitz, C. S., Schwartz, L. H., Zakowski, M. F., Rizvi, N. A., Kris, M. G., & Ginsberg, M. S. (2011) · Lung Cancer · doi:10.1016/j.lungcan.2011.08.001 · Cited by 59 · cited 1×
“Our data are consistent with previous reports in that CT measurements tended to overestimate the true pathologic size of the tumors with a significant difference.(37,38) Furthermore, in this study, 3D solid CT measurements also showed a tendency to overestimate the invasive component, whereas 2D solid CT measurements…”
ResultPark, C. M., Goo, J. M., Lee, H. J., Kim, K. G., Kang, M., & Shin, Y. H. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.4157 · Cited by 44
Self-citationSublobar Versus Lobar Resection: Current Status
Narsule, C. K., Ebright, M. I., & Fernando, H. C. (2011) · The Cancer Journal · doi:10.1097/ppo.0b013e31820a51b6 · Cited by 38
Yanagawa, M., Kuriyama, K., Kunitomi, Y., Tomiyama, N., Honda, O., Sumikawa, H., INOUE, A., Mihara, N., Yoshida, S., Johkoh, T., et al. (2009) · British Journal of Radiology · doi:10.1259/bjr/70480730 · Cited by 25
Cited by
MacMahon, H., Naidich, D. P., Goo, J. M., Lee, K. S., Leung, A. N. C., Mayo, J. R., Mehta, A. C., Ohno, Y., Powell, C. A., Prokop, M., et al. (2017) · Radiology · doi:10.1148/radiol.2017161659 · Cited by 2,491
Self-citationCallister, M. E. J., Baldwin, D. R., Akram, A. R., Barnard, S., Cane, P., Draffan, J., Franks, K., Gleeson, F., Graham, R., Malhotra, P., et al. (2015) · Thorax · doi:10.1136/thoraxjnl-2015-207168 · Cited by 958
Travis, W. D., Asamura, H., Bankier, A. A., Beasley, M. B., Detterbeck, F., Flieder, D. B., Goo, J. M., MacMahon, H., Naidich, D., Nicholson, A. G., et al. (2016) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.03.025 · Cited by 722
Self-citationRecommendations for Measuring Pulmonary Nodules at CT: A Statement from the Fleischner Society
Bankier, A. A., MacMahon, H., Goo, J. M., Rubin, G. D., Schaefer-Prokop, C. M., & Naidich, D. P. (2017) · Radiology · doi:10.1148/radiol.2017162894 · Cited by 347
Self-citationNatural History of Pulmonary Subsolid Nodules: A Prospective Multicenter Study
Kakinuma, R., Noguchi, M., Ashizawa, K., Kuriyama, K., Maeshima, A. M., Koizumi, N., Kondo, T., Matsuguma, H., Nitta, N., Ohmatsu, H., et al. (2016) · Journal of Thoracic Oncology · doi:10.1016/j.jtho.2016.04.006 · Cited by 277
Metadata
- Authors
- Lee, K. H., Goo, J. M., Park, S. J., Wi, J. Y., Chung, D. H., Go, H., Park, H. S., Park, C. M., & Lee, S. M.
- Venue
- Journal of Thoracic Oncology
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 9
- Issue
- 1
- Pages
- 74-82
- ISSN
- 1556-0864 (ISSN-L)
- OpenAlex
- W2051183700
- Cited by
- 238
- References
- 16
- FWCI
- 8.77
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.