The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans
Open accessAbstract
HYPOTHESIS: This study evaluates the types and degrees of tissue response adjacent to the electrode of multichannel cochlear implants. BACKGROUND: Cochlear implant electrodes have been classified as biocompatible prostheses. Nevertheless, in some reports, electrode extrusion, chronic inflammation, and even soft failure of the implant system have been attributed to a tissue response to the electrode. METHODS: All celloidin-embedded temporal bones with multichannel cochlear implants from the temporal bone collection of the Massachusetts Eye and Ear Infirmary were included in the study. A total of 28 temporal bones from 21 subjects were identified and processed for histology. The severity of cellular response including eosinophil and lymphocytic infiltration, giant cell reaction, new bone formation, and fibrosis were scored on a scale from 0 to 3 at three 1-mm segments along the electrode: first 1 mm at the cochleostomy, last 1 mm from the tip of the electrode, and midway between these proximal and distal segments. The values were compared using the Wilcoxon test. RESULTS: A granulomatous reaction to the electrode was observed in 27 (96.4%) temporal bones. Eosinophil infiltration was observed in 7 (25%) temporal bones, suggesting an allergic reaction. The Inflammatory response to the electrode was significantly greater at the basal turn of cochlea close to the cochleostomy (p < 0.05) than distal to it. CONCLUSION: An inflammatory response is common after cochlear implantation, and it is more robust at the cochleostomy than distal to it, suggesting the role of trauma of insertion as a contributing factor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Foreign body reaction to biomaterials
Anderson, J. M., Rodriguez, A., & Chang, D. T. (2008) · Seminars in Immunology · doi:10.1016/j.smim.2007.11.004 · Cited by 5,138 · cited 1×
“Granulation tissue is the precursor of fibrous capsule formation, and granulation tissue is separated from the implant by the cellular components of the foreign body reaction, a one- to two-cell layer of macrophages, and foreign body giant cells (30).”
BackgroundA review on macrophage responses to biomaterials
Xia, Z., & Triffitt, J. T. (2006) · Biomedical Materials · doi:10.1088/1748-6041/1/1/r01 · Cited by 418
Interleukin-13 induces human monocyte/macrophage fusion and macrophage mannose receptor expression
DeFife, K. M., Jenney, C. R., McNally, A. K., Colton, E., & Anderson, J. M. (1997) · The Journal of Immunology · doi:10.4049/jimmunol.158.7.3385 · Cited by 228
Cited by
Zhang, D., Chen, Q., Shi, C., Chen, M., Ma, K., Wan, J., & Liu, R. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007226 · Cited by 303
Metadata
- Authors
- Seyyedi, M., & Nadol, J. B.
- Venue
- Otology & Neurotology
- Published
- 2014-10
- Volume
- 35
- Issue
- 9
- Pages
- 1545-1551
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W2324920653
- Cited by
- 201
- References
- 3
- FWCI
- 6.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans. https://app.cochat.ai/papers/10.1097/mao.0000000000000540
- The paper
- Seyyedi, M., & Nadol, J. B. (2014). Intracochlear Inflammatory Response to Cochlear Implant Electrodes in Humans. Otology & Neurotology. https://doi.org/10.1097/mao.0000000000000540
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.