The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Intratympanic Versus Intravenous Delivery of Methylprednisolone to Cochlear Perilymph
Abstract
OBJECTIVE: To compare methylprednisolone concentrations in the perilymph of the human ear and in plasma after intratympanic (IT) or intravenous (IV) administration. METHODS: Methylprednisolone concentrations in the perilymph of patients during cochlear implantation were compared after 3 dosing strategies of methylprednisolone solution for injection (40 mg/ml): 1) IT administration of up to 40 mg was injected into the middle ear through the external auditory canal via a 27-gauge needle passed through a small anterosuperior myringotomy; 2) IV administration of 1 mg/kg was given as a single injection over 30 seconds; 3) IV administration of 10 mg/kg was infused over 30 minutes. Perilymph (single sample, approximately 20 microL) was sampled using a needle passed through the round window membrane, from 0.5 to 3 hours after dosing. In most patients, simultaneous blood sampling was performed. Methylprednisolone concentrations were measured by high-performance liquid chromatography with a limit of quantification of 0.001 mg/L. RESULTS: In 39 patients studied, 33 perilymph samples were suitable for measurement, along with 26 plasma samples. Median perilymph concentrations were 6.7 mg/L (n = 18; range, 0.2-89.4 mg/L) after IT administration, 0.053 mg/L (n = 8; range, 0-0.47 mg/L) after IV injection of 1 mg/kg, and 0.2 mg/L (n = 7; range, 0.067-3.1 mg/L) after IV infusion of 10 mg/kg. The median perilymph concentrations were 126-fold higher after the IT administration than after 1 mg/kg IV (p = 0.0003) and 33-fold higher than after 10 mg/kg IV infusion (p = 0.0045). Plasma concentrations after IT administration were 16-fold lower than after IV administration of 1 mg/kg (p = 0.0006), and 136-fold lower than after IV infusion of 10 mg/kg (p = 0.0006). CONCLUSION: IT administration of methylprednisolone in humans results in much higher perilymph concentrations and much lower systemic concentrations than IV administration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parnes, L. S., Sun, A., & Freeman, D. J. (1999) · The Laryngoscope · doi:10.1097/00005537-199907001-00001 · Cited by 634
Cited by
Incidence of Sudden Sensorineural Hearing Loss
Alexander, T. H., & Harris, J. P. (2013) · Otology & Neurotology · doi:10.1097/mao.0000000000000222 · Cited by 443
Principles of Local Drug Delivery to the Inner Ear
Salt, A. N., & Plontke, S. K. (2009) · Audiology and Neurotology · doi:10.1159/000241892 · Cited by 253
International consensus (ICON) on treatment of sudden sensorineural hearing loss
Marx, M., Younes, E., Chandrasekhar, S. S., Ito, J., Plontke, S., O’Leary, S., & Sterkers, O. (2018) · European Annals of Otorhinolaryngology, Head and Neck Diseases · doi:10.1016/j.anorl.2017.12.011 · Cited by 152
Alexander, T. H., Harris, J. P., Nguyen, Q. T., & Vorasubin, N. (2015) · Otology & Neurotology · doi:10.1097/mao.0000000000000834 · Cited by 48
Metadata
- Authors
- Bird, P. A., Begg, E. J., Zhang, M., Keast, A. T., Murray, D. P., & Balkany, T. J.
- Venue
- Otology & Neurotology
- Published
- 2007-12
- Volume
- 28
- Issue
- 8
- Pages
- 1124-1130
- ISSN
- 1531-7129 (ISSN-L)
- OpenAlex
- W2030877917
- Cited by
- 227
- References
- 1
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Intratympanic Versus Intravenous Delivery of Methylprednisolone to Cochlear Perilymph. https://app.cochat.ai/papers/10.1097/mao.0b013e31815aee21
- The paper
- Bird, P. A., Begg, E. J., Zhang, M., Keast, A. T., Murray, D. P., & Balkany, T. J. (2007). Intratympanic Versus Intravenous Delivery of Methylprednisolone to Cochlear Perilymph. Otology & Neurotology. https://doi.org/10.1097/mao.0b013e31815aee21
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.