CoChat

Assessment of More Than 1,000 Implanted Percutaneous Bone Conduction Devices: Skin Reactions and Implant Survival

Dun, Catharina A. J., Faber, Hubert T., de Wolf, Maarten J. F., Mylanus, Emmanuel A. M., Cremers, Cor W. R. J., Hol, Myrthe K. S. · 2012 · Otology & Neurotology
Cited by 162

The DOI matches its Crossref record.

Abstract

OBJECTIVE: This study assesses soft tissue reactions and implant stability of 1,132 percutaneous titanium implants (970 patients) for bone conduction devices (BCDs). In addition, it examines BCD usage and comparisons between different patient groups. STUDY DESIGN: Retrospective survey. Mean follow-up time of 4.6 years. SETTING: Tertiary care referral center. PATIENTS: The surveyed cohort was divided into 3 different age groups (children, adults, and the elderly). In addition, 4 groups with variable loading times (i.e., the time between placement of the implant and loading the BCD sound processor) were identified as well as a subgroup of patients with mental retardation. MAIN OUTCOME MEASURES: Soft tissue reactions around the percutaneous implants as classified by the Holgers grading system, implant failure, and revision surgery rates. RESULTS: In 95.5% of the 7,415 observations of 1,132 implants, there were no adverse soft tissue reactions. Implant loss was 8.3%. Significantly more soft tissue reactions and implant failures were observed in children compared with adults and the elderly (p < 0.05). Implant survival was lower in patients with mental retardation compared with patients without mental retardation (p = 0.001). The loading time did not influence the occurrence of soft tissue reactions and implant survival rates. CONCLUSION: Children and patients with mental retardation are the most vulnerable to soft tissue reactions and implant losses. Additional and more frequent care needs to be given during outpatient consultations. Because loading as early as 3 to 5 weeks did not negatively affect skin reactions or implant survival, full BCD installation can occur earlier without risk.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/mao.0b013e318241c0bf

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 162

Metadata

Authors
Dun, C. A. J., Faber, H. T., de Wolf, M. J. F., Mylanus, E. A. M., Cremers, C. W. R. J., & Hol, M. K. S.
Venue
Otology & Neurotology
Published
2012-02
Volume
33
Issue
2
Pages
192-198
ISSN
1531-7129 (ISSN-L)
OpenAlex
W1974811553
Cited by
162
References
0
FWCI
6.29
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Assessment of More Than 1,000 Implanted Percutaneous Bone Conduction Devices: Skin Reactions and Implant Survival. https://app.cochat.ai/papers/10.1097/mao.0b013e318241c0bf
The paper
Dun, C. A. J., Faber, H. T., de Wolf, M. J. F., Mylanus, E. A. M., Cremers, C. W. R. J., & Hol, M. K. S. (2012). Assessment of More Than 1,000 Implanted Percutaneous Bone Conduction Devices: Skin Reactions and Implant Survival. Otology & Neurotology. https://doi.org/10.1097/mao.0b013e318241c0bf

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.