Recirculation in Venovenous Extracorporeal Membrane Oxygenation
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Recirculation, a phenomenon in which reinfused oxygenated blood is withdrawn by the drainage cannula without passing through the systemic circulation, decreases the efficiency with which venovenous extracorporeal membrane oxygenation (ECMO) provides oxygenation. The precise amount of recirculation may be difficult to quantify. However, interventions should be attempted to reduce recirculation when oxygen delivery is suboptimal and recirculation is suspected. Several techniques, including the use of dual-lumen cannulae, have been successful in minimizing recirculation in venovenous ECMO. This article will provide an overview of the factors that affect recirculation, methods that may be used to quantify recirculation, and interventions that may reduce recirculation, thereby increasing ECMO efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Extracorporeal Membrane Oxygenation for ARDS in Adults
Brodie, D., & Bacchetta, M. (2011) · New England Journal of Medicine · doi:10.1056/nejmct1103720 · Cited by 836
Self-citationSchmidt, M., Tachon, G., Devilliers, C., Muller, G., Hekimian, G., Bréchot, N., Merceron, S., Luyt, C. E., Trouillet, J.-L., Chastre, J., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2785-8 · Cited by 356
Theory and validation of access flow measurement by dilution technique during hemodialysis
Krivitski, N. M. (1995) · Kidney International · doi:10.1038/ki.1995.290 · Cited by 327
Wang-Zwische Double Lumen Cannula—Toward a Percutaneous and Ambulatory Paracorporeal Artificial Lung
Wang, D., Zhou, X., Liu, X., Sidor, B., Lynch, J. E., & Zwischenberger, J. B. (2008) · ASAIO Journal · doi:10.1097/mat.0b013e31818c69ab · Cited by 157
Insertion of Bicaval Dual Lumen Extracorporeal Membrane Oxygenation Catheter with Image Guidance
Javidfar, J., Wang, D., Zwischenberger, J. B., Costa, J. A., Mongero, L. B., Sonett, J. R., & Bacchetta, M. D. (2011) · ASAIO Journal · doi:10.1097/mat.0b013e3182155fee · Cited by 121
Self-citationHemodialysis Access Recirculation Measured by Ultrasound Dilution
Depner, T. A., Krivitski, N. M., & MacGibbon, D. R. (1995) · ASAIO Journal · doi:10.1097/00002480-199507000-00113 · Cited by 95
Bonacchi, M., Harmelin, G., Peris, A., & Sani, G. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.01.046 · Cited by 59
van Heijst, A. F. J., van der Staak, F. H., Haan, A. F. D., Liem, K. D., Festen, C., Geven, W. B., & van de Bor, M. (2001) · ASAIO Journal · doi:10.1097/00002480-200107000-00015 · Cited by 56
ECMO for Adult Respiratory Failure: Current Use and Evolving Applications
Agerstrand, C. L., Bacchetta, M. D., & Brodie, D. (2014) · ASAIO Journal · doi:10.1097/mat.0000000000000062 · Cited by 52
Self-citation
Cited by
Extracorporeal life support for adults with acute respiratory distress syndrome
Combes, A., Schmidt, M., Hodgson, C. L., Fan, E., Ferguson, N. D., Fraser, J. F., Jaber, S., Pesenti, A., Ranieri, M., Rowan, K., et al. (2020) · Intensive Care Medicine · doi:10.1007/s00134-020-06290-1 · Cited by 201
Self-citationEchocardiography for adult patients supported with extracorporeal membrane oxygenation
Douflé, G., Roscoe, A., Billia, F., & Fan, E. (2015) · Critical Care · doi:10.1186/s13054-015-1042-2 · Cited by 168
“Its advantages are single site cannulation and a decreased propensity for recirculation [31].”
Background
Metadata
- Authors
- Abrams, D., Bacchetta, M., & Brodie, D.
- Venue
- ASAIO Journal
- Published
- 2015-03
- Volume
- 61
- Issue
- 2
- Pages
- 115-121
- ISSN
- 1058-2916 (ISSN-L)
- OpenAlex
- W2333433770
- Cited by
- 167
- References
- 9
- FWCI
- 3.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recirculation in Venovenous Extracorporeal Membrane Oxygenation. https://app.cochat.ai/papers/10.1097/mat.0000000000000179
- The paper
- Abrams, D., Bacchetta, M., & Brodie, D. (2015). Recirculation in Venovenous Extracorporeal Membrane Oxygenation. ASAIO Journal. https://doi.org/10.1097/mat.0000000000000179
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.