Reliability of home blood pressure monitoring: in the context of validation and accuracy
The DOI matches its Crossref record.
Abstract
OBJECTIVE: Home blood pressure (BP) monitoring offers clinically relevant information enriched with more abundant data. However, there are few studies addressing the reliability of home BP devices and the quality of its data. This study aimed to evaluate the current status of home BP devices in terms of validation and accuracy. PARTICIPANTS AND METHODS: Hypertensive patients with automated upper arm-type BP devices were consecutively enrolled. First, the validation status of each device was assessed through the website. Next, the accuracy of the individual device was evaluated by comparing the mean BP values between the automated device and a mercury sphygmomanometer. Accuracy of the device was defined as having less than a 5 mmHg difference in the mean BP values. RESULTS: A total of 212 individuals were analyzed; 38.7% (82 of 212) of the participants used validated devices and 85.4% (181 of 212) were accurate. Inaccuracy was more common with nonvalidated devices than validated devices [19.2% (n=25) vs. 7.3% (n=6), P=0.017]. The range of inaccuracy of the validated devices was 6-26 mmHg for the systolic BP and 6-11 mmHg for the diastolic BP. CONCLUSION: The present study showed that nonvalidated devices are used widely in clinical practice and a substantial portion is inaccurate. Therefore, recommendation of validated devices should be the first step. Furthermore, all devices need to be examined for accuracy before use irrespective of their validation status.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sharman, J. E., O’Brien, E., Alpert, B., Schutte, A. E., Delles, C., Hecht Olsen, M., Asmar, R., Atkins, N., Barbosa, E., Calhoun, D., et al. (2020) · Journal of Hypertension · doi:10.1097/hjh.0000000000002246 · Cited by 139
Picone, D. S., Deshpande, R. A., Schultz, M. G., Fonseca, R., Campbell, N. R. C., Delles, C., Hecht Olsen, M., Schutte, A. E., Stergiou, G., Padwal, R., et al. (2020) · Hypertension · doi:10.1161/hypertensionaha.120.14719 · Cited by 118
Padwal, R., Campbell, N. R. C., Schutte, A. E., Olsen, M. H., Delles, C., Etyang, A., Cruickshank, J. K., Stergiou, G., Rakotz, M. K., Wozniak, G., et al. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000002112 · Cited by 108
How to check whether a blood pressure monitor has been properly validated for accuracy
Picone, D. S., Padwal, R., Campbell, N. R. C., Boutouyrie, P., Brady, T. M., Olsen, M. H., Delles, C., Lombardi, C., Mahmud, A., Meng, Y., et al. (2020) · The Journal of Clinical Hypertension · doi:10.1111/jch.14065 · Cited by 52
Hodgkinson, J. A., Lee, M.-M., Milner, S., Bradburn, P., Stevens, R., Hobbs, F. R., Koshiaris, C., Grant, S., Mant, J., & McManus, R. J. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x710381 · Cited by 52
Metadata
- Authors
- Jung, M.-H., Kim, G.-H., Kim, J.-H., Moon, K.-W., Yoo, K.-D., Rho, T.-H., & Kim, C.-M.
- Venue
- Blood Pressure Monitoring
- Published
- 2015-08
- Volume
- 20
- Issue
- 4
- Pages
- 215-220
- ISSN
- 1359-5237 (ISSN-L)
- OpenAlex
- W2002908936
- Cited by
- 55
- References
- 0
- FWCI
- 2.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability of home blood pressure monitoring: in the context of validation and accuracy. https://app.cochat.ai/papers/10.1097/mbp.0000000000000121
- The paper
- Jung, M.-H., Kim, G.-H., Kim, J.-H., Moon, K.-W., Yoo, K.-D., Rho, T.-H., & Kim, C.-M. (2015). Reliability of home blood pressure monitoring: in the context of validation and accuracy. Blood Pressure Monitoring. https://doi.org/10.1097/mbp.0000000000000121
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.